Wonhyo Kim

Wonhyo Kim


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 November 2015 in Sensors
Verified
Journal Article
Open access
PDF file
WKWonhyo Kim
Wonhyo Kim
HOHaekwan Oh
Haekwan Oh
YKYeonhwa Kwak
Yeonhwa Kwak
KPKwangbum Park
Kwangbum Park
BJByeong-Kwon Ju
Byeong-Kwon Ju
KKKunnyun Kim
Kunnyun Kim
A force sensing touchscreen, which detects touch point and touch force simultaneously by sensing a change in electric capacitance, was designed and fabricated. It was made with single-walled carbon nanotubes (SWCNTs) which have better mechanical and chemical characteristics than the indium-tin-oxide transparent electrodes used in most contemporary touchscreen devices. The SWCNTs, with a transmittance of about 85% and electric conductivity of 400 Ω per square; were coated and patterned on glass and polyethyleneterephthalate (PET) film substrates. The constructed force sensing touchscreen has a total size and thickness of 62 mm × 100 mm × 1.4 mm, and is composed of 11 driving line and 19 receiving line channels. The gap between the channels was designed to be 20 µm, taking visibility into consideration, and patterned by a photolithography and plasma etching processes. The mutual capacitance formed by the upper and lower transparent electrodes was initially about 2.8 pF and, on applying a 500 gf force with a 3 mm diameter tip, it showed a 25% capacitance variation. Furthermore, the touchscreen can detect multiple touches and forces simultaneously and is unaffected by touch material characteristics, such as conductance or non-conductance.

12 July 2018 in Sensors
Verified
Journal Article
Open access
PDF file
SLSungho Lee
Sungho Lee
SHSungmin Hong
Sungmin Hong
WPWonki Park
Wonki Park
WKWonhyo Kim
Wonhyo Kim
JLJae Hoon Lee
Jae Hoon Lee
Daesung LeeDaesung Lee
Daesung Lee
In this paper, we propose a high accuracy open-type current sensor with a differential Planar Hall Resistive (PHR) sensor. Conventional open-type current sensors with magnetic sensors are usually vulnerable to interference from an external magnetic field. To reduce the effect of an unintended magnetic field, the proposed design uses a differential structure with PHR. The differential structure provides robust performance to unwanted magnetic flux and increased magnetic sensitivity. In addition, instead of conventional Hall sensors with a magnetic concentrator, a newly developed PHR with high sensitivity is employed to sense horizontal magnetic fields. The PHR sensor and read-out integrated circuit (IC) are integrated through a post-Complementary metal-oxide-semiconductor (CMOS) process using multi-chip packaging. The current sensor is designed to measure a 1 A current level. The measured performance of the designed current sensor has a 16 kHz bandwidth and a current nonlinearity of under ±0.5%.

1 December 2023 in IEEE Sensors Journal
Verified
Journal Article
Closed access
Yangkyu ParkYangkyu Park
Yangkyu Park
NGNa-Hyeon Gwon
Na-Hyeon Gwon
WSWoo-Kyeong Seong
Woo-Kyeong Seong
WKWonhyo Kim
Wonhyo Kim
With the growing popularity of autonomous vehicles, the need for real-time monitoring of occupant posture has led to the requirement for a pressure sensor array. Moreover, heated car seats not only offer drivers comfort but also prevent cramped postures, allowing pressure sensors to accurately measure drivers’ pressure distribution and enhance safety in autonomous driving. Herein, we propose a heater-integrated pressure sensor array designed specifically for seats in a commercially available GV80 car. The unique signal lines in our sensor enable the implementation of both sensing and heating functionalities within single substrate, streamlining the fabrication process for the heater-integrated sensor. The sensor was characterized in terms of sensitivity, linearity, response time, repeatability, hysteresis, body temperature effect, and pressure interference among sensing elements. Our sensor exhibited a wide linearity region of 17.06 kPa with a maximum linearity error of 4.4 % and fast response time of less than 4 ms. It operated reliably, with a maximum relative standard deviation of 5.2 % and a hysteresis error of 12.2 %. The maximum resistance difference affected by the body temperature was as small as 8.5 %, and the resistance changes of one sensing element were almost constant, regardless of the pressure applied to the other sensing element. Additionally, we studied the variations in sensor characteristics with respect to heater temperatures. Furthermore, we customized the embedded system and graphical user interface to demonstrate sensor responses according to five different postures. Thus, our heater-integrated sensor shows promise as a potential device for emerging smart-car seats. (Max. 250 words).

18 November 2020 in BioChip Journal
Verified
Journal Article
Closed access
PDF file
HKHye-Lim Kang
Hye-Lim Kang
SYSumi Yoon
Sumi Yoon
DHDong-Ki Hong
Dong-Ki Hong
SSSunga Song
Sunga Song
YKYoung Joo Kim
Young Joo Kim
KLKook-Nyung Lee
Kook-Nyung Lee