Beladel Abdelkader

Dr. Beladel Abdelkader

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2025 in Energy Reports
Verified
Journal Article
Open access
DBDerradji Bakria
Derradji Bakria
BABeladel Abdelkader
Beladel Abdelkader
BKBelkacem Korich
Belkacem Korich
ATAli Teta
Ali Teta
RMRIDHA DJAMEL MOHAMMEDI
RIDHA DJAMEL MOHAMMEDI
EEEl-Sayed El-Kenawy
El-Sayed El-Kenawy

1 September 2019
Verified
Conference Paper
Closed access
ELBAR MohamedELBAR Mohamed
ELBAR Mohamed
BABeladel Abdelkader
Beladel Abdelkader
kouzou Abdellahkouzou Abdellah
kouzou Abdellah
Hafaifa AhmedHafaifa Ahmed
Hafaifa Ahmed
Reactive and harmonic currents that are being injected in the power supply by nonlinear loads, cause an increasing deterioration of the power system voltages and currents. Whereas active power filter (APF) have been widely used to overcome this problem and to improve the power quality delivered by the power supply. In this paper, three-level four-legged active power filter based on neutral-point-clamped (NPC) inverter is presented. To fulfill the requirement of the active power filtering function under balanced, unbalance and distorted (including 3rd and 5th harmonics) power supply voltages, A control methods based on the instantaneous power theory have been used and discussed. On the otherside, the inverter switching state control has been achieved based on PWM current controller. The performance of the proposed topology under the used control approach has been finally discussed through the obtained simulation results.

9 October 2026 in Machines
Verified
Journal Article
Open access
PDF file
MBMohammed lamine Belkheiri
Mohammed lamine Belkheiri
BABeladel Abdelkader
Beladel Abdelkader
kouzou Abdellahkouzou Abdellah
kouzou Abdellah
Jose RodriguezJose Rodriguez
Jose Rodriguez
Mohamed AbdelrahemMohamed Abdelrahem
Mohamed Abdelrahem
This paper presents a novel dynamic configuration for ensuring long-term fault-tolerant operation of three-phase open-end winding induction motors (3P-OEWIM). Conventional strategies are limited by their inability to sustain performance under multiple simultaneous failures, particularly when faults affect both inverters or power sources. To address these limitations, this study proposes an integrated topology that combines fault-tolerant techniques from conventional star-connected drives, common DC supply OEWIM, and separate DC supplies OEWIM configurations. The proposed system dynamically reconfigures its power topology in response to fault conditions, maintaining rated power operation whenever possible and transitioning to reduced-power or two-phase modes under compound faults. Simulation results demonstrate that the proposed strategy enhances system resilience against consecutive failures, including combined DC supply and inverter faults. Integrating these multiple strategies into a single dynamic topology improves operational continuity, making 3P-OEWIM drives more resilient for critical applications such as electric vehicles and industrial automation.

10 August 2026 in Sustainability
Verified
Journal Article
Open access
PDF file
MBMOHAMED LAMINE BENAISSA
MOHAMED LAMINE BENAISSA
BABeladel Abdelkader
Beladel Abdelkader
kouzou Abdellahkouzou Abdellah
kouzou Abdellah
Jose RodriguezJose Rodriguez
Jose Rodriguez
Mohamed AbdelrahemMohamed Abdelrahem
Mohamed Abdelrahem
This study considers the multi-objective optimization of a standalone hybrid nanogrid system (HNGS) providing electricity power to a residential load in an off-grid area of Djelfa Province, Algeria. The focus of this study is to obtain the optimum design of a standalone hybrid nanogrid system consisting of photovoltaic (PV) panels, wind turbines (WTs), battery storage (BT), diesel generators (DGs), and power converters to satisfy the energy demand of residential consumers in Djelfa Province, Algeria. In this context, four multi-objective optimization algorithms (MOPs), NSGA-II, MOPSO, MOSSA, and MODE, are used to solve the optimal sizing problem of the proposed system. The formulated multi-objective optimization problem takes into account multiple performance criteria such as cost of energy (COE), loss of power supply probability (LPSP), renewable energy penetration, and diesel generator usage reduction, balancing economic, reliability, and sustainability aspects. The optimization process optimizes critical design parameters, including the size of the PV system, the number of wind turbines, and the size of the battery storage system, for a realistic operating scenario. The optimization algorithms are combined with an energy management strategy (EMS) that helps to coordinate the power flow distribution between various parts of the system to achieve optimum system performance. The effectiveness of each of the proposed approaches is analyzed based on the obtained results, where it was found that the MODE algorithm provides the best compromise solution, with a COE of 0.167 USD/kWh and an LPSP of 6.372%, and the lowest carbon dioxide emissions of 205.1 kg/year compared to MOPSO, NSGA-II, and MOSSA. Moreover, the results obtained from this process will provide a set of feasible design solutions, which will allow decision-makers to choose the most suitable design solution based on technical and economic specifications.