Agostino Igor Mirulla

Dr. Agostino Igor Mirulla

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2021 in Computer Methods and Programs in Biomedicine
Verified
Journal Article
Closed access
AMAgostino Igor Mirulla
Agostino Igor Mirulla
SPSalvatore Pinelli
Salvatore Pinelli
SZStefano Zaffagnini
Stefano Zaffagnini
VNVincenzo Nigrelli
Vincenzo Nigrelli
TITommaso Ingrassia
Tommaso Ingrassia
LBLaura Bragonzoni
Laura Bragonzoni

1 April 2018 in Injury
Verified
Journal Article
Closed access
AMAgostino Igor Mirulla
Agostino Igor Mirulla
LBL. Bragonzoni
L. Bragonzoni
SZStefano Zaffagnini
Stefano Zaffagnini
MBM. Bontempi
M. Bontempi
VNV. Nigrelli
V. Nigrelli
TITommaso Ingrassia
Tommaso Ingrassia

12 May 2022 in Computer Methods and Programs in Biomedicine
Verified
Journal Article
Closed access
AMAgostino Igor Mirulla
Agostino Igor Mirulla
GMGiulio Maria Marcheggiani Muccioli
Giulio Maria Marcheggiani Muccioli
SFStefano Fratini
Stefano Fratini
SZStefano Zaffagnini
Stefano Zaffagnini
TITommaso Ingrassia
Tommaso Ingrassia
Bernardo InnocentiBernardo Innocenti
Bernardo Innocenti

17 April 2023 in Sensors
Verified
Journal Article
Open access
PDF file
SPStefano Di Paolo
Stefano Di Paolo
GBGiuseppe Barone
Giuseppe Barone
DADomenico Alesi
Domenico Alesi
AMAgostino Igor Mirulla
Agostino Igor Mirulla
EGEmanuele Gruppioni
Emanuele Gruppioni
LBLaura Bragonzoni
Laura Bragonzoni
The aim of the present case report was to provide a longitudinal functional assessment of a patient with transfemoral amputation from the preoperative status with socket-type prosthesis to one year after the osseointegration surgery. A 44 years-old male patient was scheduled for osseointegration surgery 17 years after transfemoral amputation. Gait analysis was performed through 15 wearable inertial sensors (MTw Awinda, Xsens) before surgery (patient wearing his standard socket-type prosthesis) and at 3-, 6-, and 12-month follow-ups after osseointegration. ANOVA in Statistical Parametric Mapping was used to assess the changes in amputee and sound limb hip and pelvis kinematics. The gait symmetry index progressively improved from the pre-op with socket-type (1.14) to the last follow-up (1.04). Step width after osseointegration surgery was half of the pre-op. Hip flexion-extension range significantly improved at follow-ups while frontal and transverse plane rotations decreased (p < 0.001). Pelvis anteversion, obliquity, and rotation also decreased over time (p < 0.001). Spatiotemporal and gait kinematics improved after osseointegration surgery. One year after surgery, symmetry indices were close to non-pathological gait and gait compensation was sensibly decreased. From a functional point of view, osseointegration surgery could be a valid solution in patients with transfemoral amputation facing issues with traditional socket-type prosthesis.

21 November 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
AMAgostino Igor Mirulla
Agostino Igor Mirulla
SPStefano Di Paolo
Stefano Di Paolo
FSFrancesco Di Simone
Francesco Di Simone
TITommaso Ingrassia
Tommaso Ingrassia
VNVincenzo Nigrelli
Vincenzo Nigrelli
LBLaura Bragonzoni
Laura Bragonzoni
In the last two decades, osseointegrated prostheses have been shown to be a good alternative for lower limb amputees experiencing complications in using a traditional socket-type prosthesis; however, restraining biomechanical issues, such as peri-prosthetic bone fractures or loosening, are present. To better understand and overcome these limiting issues, and thus reduce the number of implant failures, many studies have investigated the stress distribution on bone and implant during normal daily activities. The aim of this study was a biomechanical analysis of two different osseointegrated implants, a screw-type (OPRA) and a press fit system (OPL, Osseointegrated Prosthetic Limb), to evaluate the stresses generated in bone and prosthesis during a fall. In particular, four scenarios have been experimentally reproduced to determine the loads on the limb during different kinds of fall. For this purpose, a motion capture system and a force plate have been used. Numerical FEM (Finite Element Method) simulations have been performed to compare the behaviour of the OPRA and OPL systems in different fall scenarios. The obtained results showed that a fall backwards due to balance loss is the most stressful scenario among the ones analysed. As regards the comparison between OPRA and OPL devices, it emerged they have similar behaviours in terms of peak values of the stress, but the OPL implant generates larger high-stress areas in the distal femur as compared with the OPRA system.

17 July 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
ACAntonino CIRELLO
Antonino CIRELLO
TITommaso Ingrassia
Tommaso Ingrassia
Giuseppe MarannanoGiuseppe Marannano
Giuseppe Marannano
AMAgostino Igor Mirulla
Agostino Igor Mirulla
VNVincenzo Nigrelli
Vincenzo Nigrelli
Vito RicottaVito Ricotta
Vito Ricotta
As is widely recognized, advancements in new design and rapid prototyping techniques such as CAD modeling and 3D printing are pioneering individualized medicine, facilitating the implementation of new methodologies for creating customized orthoses. The aim of this paper is to develop a new automatic technique for producing personalized orthoses in a straightforward manner, eliminating the necessity for doctors to collaborate directly with technicians. A novel design method for creating customized wrist orthoses has been implemented, notably featuring a generative algorithm for the parametric modeling of the orthosis. To assess the efficacy of the developed algorithm, a case study was conducted involving the design and rapid prototyping of a wrist orthosis using Fused Deposition Modeling (FDM) technology. Subsequently, the developed algorithm was tested by clinicians and patients. The results obtained indicate that the implemented algorithm is user-friendly and could potentially enable non-expert users to design customized orthoses. These results introduce innovative elements of originality within the CAD modeling, offering promising solutions to the challenges associated with the design and production of customized orthoses. Future developments could consist of a better investigation regarding the parameters that influence the accuracy of the scanning and of the printing processes.