Cristiana Bragalli

Prof. Cristiana Bragalli

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 May 2023 in International Journal of Water Resources Development
Verified
Journal Article
Open access
Sandra RicartSandra Ricart
Sandra Ricart
RVRUBÉN VILLAR-NAVASCUÉS
RUBÉN VILLAR-NAVASCUÉS
MRMaría Reyes
María Reyes
Antonio Rico AmorósAntonio Rico Amorós
Antonio Rico Amorós
MHMaria Hernandez Hernández
Maria Hernandez Hernández
Bas AmelungBas Amelung
Bas Amelung

30 June 2011 in Journal of Hydroinformatics
Verified
Journal Article
Closed access
PDF file
SASandro Artina
Sandro Artina
CBCristiana Bragalli
Cristiana Bragalli
GEGiovanni Erbacci
Giovanni Erbacci
AMAngela Marchi
Angela Marchi
MRMarzia Rivi
Marzia Rivi
Optimization of water distribution networks is a NP-hard problem that researchers have tried to deal with using different formulations and algorithmic approaches. Among these, multi-objective heuristic algorithms are interesting because of their capacity for dealing with separate objectives that allow us to choose a posteriori the best compromise, but one of their main drawbacks is the long time required to obtain good solutions. Parallel processing is the most promising way to reduce the computing time and can make the convergence to adequate solutions faster. This paper intends to investigate the possibility of improving the efficacy and efficiency of an NSGA-II algorithm by parallelization of the optimization process at the same time. Results of different parallel implementations of NSGA-II applied to optimal design of small- and medium-size water distribution networks are presented. Good speed-up can be reached with a global model, hence improving the algorithm efficiency. Unlike the global model, the island model (or the hierarchical parallelization) can also improve its efficacy because it introduces fundamental changes in the algorithm exploration method. Possibilities offered by parallel island models have been investigated showing that some parameter configurations can find better solutions compared with the serial version of the algorithm.

19 February 2023 in Renewable Energy
Verified
Journal Article
Open access
CBCristiana Bragalli
Cristiana Bragalli
DMDomenico Micocci
Domenico Micocci
GNGiovanni Naldi
Giovanni Naldi

19 December 2012 in Water
Verified
Journal Article
Open access
PDF file
GCGiulio Conte
Giulio Conte
ABAndrea Bolognesi
Andrea Bolognesi
CBCristiana Bragalli
Cristiana Bragalli
SBSara Branchini
Sara Branchini
ACAlessandro De Carli
Alessandro De Carli
IPIlaria Principi
Ilaria Principi
The excessive use of water is damaging European groundwater and rivers: their environmental conditions are often below the “good status” that—according to Water Framework Directive 2000/60—should be reached by 2015. The already critical situation is tending to get worse because of climate change. Even in water rich countries, urban wastewater is still one of the main sources of water pollution. Currently, urban soil sealing and “conventional” rainwater management, which were planned to quickly move rainwater away from roofs and streets, are increasing the flood risk. “Green” technologies and approaches would permit a reduction in water abstraction and wastewater production while improving urban hydrological response to heavy rains. The Life+ WATACLIC project has been implemented to promote such sustainable technologies and approaches in Italy, however the results show huge difficulties: apparently water saving and sustainable urban water management have only low interest amongst the general public and even with public administrations and the relevant industrial sectors. In such a cultural and technical context, the project is bringing a new point of view to public debate. In the long term, the project will certainly have a positive impact, but most likely it will require more time than initially expected.

27 May 2026 in International Journal of Disaster Risk Reduction
Verified
Journal Article
Open access
Maria PoleseMaria Polese
Maria Polese
GTGabriella Tocchi
Gabriella Tocchi
Maria Fabrizia ClementeMaria Fabrizia Clemente
Maria Fabrizia Clemente
BPB. Di Palma
B. Di Palma
Marco Gaetani d'AragonaMarco Gaetani d'Aragona
Marco Gaetani d'Aragona
APA. Prota
A. Prota

23 July 2024 in Water
Verified
Journal Article
Open access
PDF file
MPMaria Rosaria Pascale
Maria Rosaria Pascale
DRDomenico Simone Roggio
Domenico Simone Roggio
EBEster Barbieri
Ester Barbieri
FMFirst 285 Marino
First 285 Marino
CDCarlo Derelitto
Carlo Derelitto
Sandra CristinoSandra Cristino
Sandra Cristino
The World Health Organization (WHO) recommends the introduction of a water safety plan (WSP) approach on drinking water, in all types of settings. This study represents the first WSP developed on the Neptune Fountain, in Bologna (Italy), based on an interdisciplinary approach, integrating hydraulic and microbiological features, in a Building Information Modeling (BIM). The aim was to develop a dynamic and digital platform to update and share the maintenance program, promoting collaboration among microbiologists, engineers, and municipal staff. Water samples were collected along fountain water distribution systems (WDS) from 2016 to 2021 to monitor water quality through the heterotrophic bacteria at 22 °C and 37 °C, as well as to conduct an Enterococci, Coliform bacteria, Escherichia coli, Pseudomonas aeruginosa, Clostridium perfringens, and Staphylococcus aureus assessment. Simultaneously, hydraulic measures were performed, and advanced geomatics techniques were used to detect the WDS structural components, with a focus on the water treatment system (WTS). The WTS consisted of 10 modules corresponding to specific treatments: descaling, carbon–sand filtration, reverse osmosis, and ultraviolet disinfection. Fecal indicators, heterotrophic bacteria, and P. aeruginosa exceeded the reference limits in most of the modules. Several disinfections and washing treatments, other than changing the maintenance procedure scheduling, were performed, improving the WTS and controlling the contamination. The developed microbiological results, hydraulic measurements, and maintenance procedures were integrated in the BIM model to optimize the data storage, updating procedures and the real-time data sharing. This approach improved the fountain management, operation, and material conservation, ultimately preserving the health of daily visitors.