To ensure the safe and stable operation of small and medium-sized wind turbine generators within distributed energy systems, a new active pitch adjustment method for a 1.5 kW distributed pitch wind turbine generator is proposed in this article. The stress and displacement responses of blades under uniform inflow and extreme operating gust inflow conditions were calculated and analyzed using a two-way fluid–structure coupling method. The results showed that under the two different flow conditions, as the pitch angle increased, the stress and displacement responses of the wind turbine blades both significantly decreased, and the decrease was greater with increasing wind speed. The feasibility of the proposed variable-pitch adjustment for blade load reduction under different inflow conditions was further illustrated. The peak of the blade stress response was located at the leading-edge position in the middle of the blades (0.55R) for the different inflow conditions, while the displacement response of the blades was mainly along the waving direction. Through comparative analysis of the blade stress and displacement responses at the same wind speed under different flow conditions, it was found that the maximum mean ratio of the blade displacement and stress responses reached 1.66 and 1.67, respectively.
This paper introduces a novel pitch adjustment device applicable to small wind turbines. To validate its feasibility under high wind speeds and analyze the impact of pitch angle on the power output characteristics of small wind turbines, a prototype model was manufactured for wind tunnel experiments. Additionally, we conducted simulations to analyze the stress and displacement responses of key components under uniform airflow, shear airflow, and Extreme Operated Gust conditions. The numerical simulation results were compared with experimental results based on actual measurement points in the wind tunnel experiment, demonstrating that the simulation data accurately reflect the experimental test results, with an overall discrepancy of around 10%, thereby validating the accuracy of the load and constraint settings in the transient dynamics analysis. This study found that, as the pitch angle increased, the structural dynamic response of key wind turbine components under uniform airflow conditions exhibited a decreasing trend, which was proportional to wind speed. Under shear airflow conditions, the response of key components was positively correlated with the shear index, while Extreme Operated Gust significantly increased the amplitude of the response fluctuations. Furthermore, this research revealed that, with an increase in pitch angle, the maximum stress value of the gear under uniform airflow conditions decreased from 27.42 MPa to 7.64 MPa, a reduction of 72.1%. Under shear airflow conditions, the root stress of the gear decreased from 14.441 MPa to 8.879 MPa, a reduction of 49.60%. Under Extreme Operated Gust conditions, the maximum stress of the gear decreased from 17.82 MPa to 15.18 MPa, a reduction of 22.99%.
Turbulent wind conditions pose significant challenges to the blade structural reliability of small wind turbines. Different from the authors’ previous work, which mainly focused on the output characteristics of the same 5 kW prototype under variable inflow conditions, this study combines field-test observations with numerical simulations to further investigate the blade structural dynamic responses of a 5 kW variable-pitch wind turbine under both uniform inflow and extreme wind conditions. Owing to the unique pitch-regulation mechanism of the proposed turbine, two pitch-control modes, namely conventional power-limited pitch control and active stall pitch control, are comparatively analyzed to clarify their effects on blade load, stress, and displacement responses. The results indicate that, under uniform inflow conditions, stresses are concentrated near the leading edge of the blade mid-span, while the maximum displacement occurs at the blade tip. Both stress and displacement decrease with increasing conventional pitch angle. Under extreme wind conditions, increasing gust intensity causes a nonlinear growth in blade loads and aggravates blade structural response. During active stall pitch control, the load distribution pattern is generally consistent with that under conventional pitch control, whereas the blade structural response first decreases and then increases as the pitch angle is adjusted toward negative values. Under uniform inflow at the rated wind speed of 11 m/s, the blade-tip maximum displacement decreased from 56.51 mm under the +6° power-limited/reference pitch condition to 48.42 mm under the −6° active-stall-related pitch condition, corresponding to a reduction of approximately 14.3%. These results provide a useful reference for the blade structural design and control optimization of distributed small wind turbines under complex inflow conditions.
Under turbulent wind conditions, rapid wind speed fluctuations can markedly increase the fatigue loads borne by wind turbine blades and towers. In practice, conventional PID pitch control based on speed feedback often struggles to deliver satisfactory load mitigation, mainly because the wind turbine system is highly nonlinear, strongly coupled, and subject to time-delay effects. To overcome these limitations, this paper proposes a load-predictive pitch control strategy built on a Long Short-Term Memory (LSTM) network. Specifically, the LSTM model is first employed to predict the hub-fixed tilt and yaw moments ahead of time. These predicted values are then introduced as feedforward signals and combined with the conventional speed-based pitch control signal as well as a proportional feedback term. After that, the inverse Coleman transformation is used to generate the individual pitch commands for each blade. To verify the effectiveness of the proposed method, co-simulations were carried out in FAST and MATLAB/Simulink on a 5000 KW distributed pitch-controlled wind turbine under IEC Kaimal spectrum wind conditions, with a mean wind speed of 18 m/s and Class B turbulence intensity. The results show that the LSTM prediction model achieves an R² of 0.998 on the test dataset, with an RMSE as low as 0.0051. Compared with the conventional pitch-based power control strategy, the proposed approach maintains the same average power output while significantly reducing fatigue loads, thereby contributing to a longer service life for the wind turbine.
Aiming at the intelligent control strategy of the hot air blower de-icing technique for wind turbine blades was requirement. A high efficient and energy-economical intelligent control strategy was designed, the control strategy workflow and two intelligent modes were designed, namely pre-heating mode and de-icing mode. Through field de-icing tests, the results showed that the inner temperature of blade tip was around 30℃ when running at pre-heating mode, the blade tip surface temperature was 5℃, which was able to restrain ice formation and supply fundamental heat for de-icing mode. The inner temperature of cavity reached 60 ℃ for supplying enough heat to de-ice quickly when running at de-icing mode. Compared with the conventional de-icing method, the intelligent de-icing control strategy was saved 80% energy consumption in one icing period, which improved electrical production. The feasibility of the intelligent control strategy was proved and it benefited for further development of wind turbine industry under cold weather conditions.
A fixed-pitch wind turbine power performance improvement technology was studied in order to solve the problem that the actual output of fixed-pitch wind turbines is lower than the rated output in the plateau areas. Considering with the environmental characteristics in plateau areas, one blade-adding technology was proposed, by adding a blade lengthening section to increase the rotor swept area to improve power performance. The software BLADED was used to simulate different length of the blades, economic benefit and safety assessment were conduct and the optimal length of the blade lengthening section was 650mm. The results indicated that a rate of 8.64% increase of power generation was gained after one year performance, the static investment period is about 3 years and the generating gain is about 1.68 million RMB in life period. The blade-adding technology can provide reference of how to improve the output of the fixed-pitch wind turbine.