Under turbulent wind conditions, rapid wind speed fluctuations can markedly increase the fatigue loads borne by wind turbine blades and towers. In practice, conventional PID pitch control based on speed feedback often struggles to deliver satisfactory load mitigation, mainly because the wind turbine system is highly nonlinear, strongly coupled, and subject to time-delay effects. To overcome these limitations, this paper proposes a load-predictive pitch control strategy built on a Long Short-Term Memory (LSTM) network. Specifically, the LSTM model is first employed to predict the hub-fixed tilt and yaw moments ahead of time. These predicted values are then introduced as feedforward signals and combined with the conventional speed-based pitch control signal as well as a proportional feedback term. After that, the inverse Coleman transformation is used to generate the individual pitch commands for each blade. To verify the effectiveness of the proposed method, co-simulations were carried out in FAST and MATLAB/Simulink on a 5000 KW distributed pitch-controlled wind turbine under IEC Kaimal spectrum wind conditions, with a mean wind speed of 18 m/s and Class B turbulence intensity. The results show that the LSTM prediction model achieves an R² of 0.998 on the test dataset, with an RMSE as low as 0.0051. Compared with the conventional pitch-based power control strategy, the proposed approach maintains the same average power output while significantly reducing fatigue loads, thereby contributing to a longer service life for the wind turbine.
Turbulent wind conditions pose significant challenges to the blade structural reliability of small wind turbines. Different from the authors’ previous work, which mainly focused on the output characteristics of the same 5 kW prototype under variable inflow conditions, this study combines field-test observations with numerical simulations to further investigate the blade structural dynamic responses of a 5 kW variable-pitch wind turbine under both uniform inflow and extreme wind conditions. Owing to the unique pitch-regulation mechanism of the proposed turbine, two pitch-control modes, namely conventional power-limited pitch control and active stall pitch control, are comparatively analyzed to clarify their effects on blade load, stress, and displacement responses. The results indicate that, under uniform inflow conditions, stresses are concentrated near the leading edge of the blade mid-span, while the maximum displacement occurs at the blade tip. Both stress and displacement decrease with increasing conventional pitch angle. Under extreme wind conditions, increasing gust intensity causes a nonlinear growth in blade loads and aggravates blade structural response. During active stall pitch control, the load distribution pattern is generally consistent with that under conventional pitch control, whereas the blade structural response first decreases and then increases as the pitch angle is adjusted toward negative values. Under uniform inflow at the rated wind speed of 11 m/s, the blade-tip maximum displacement decreased from 56.51 mm under the +6° power-limited/reference pitch condition to 48.42 mm under the −6° active-stall-related pitch condition, corresponding to a reduction of approximately 14.3%. These results provide a useful reference for the blade structural design and control optimization of distributed small wind turbines under complex inflow conditions.