坤 张

Dr. 坤 张


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2025 in Coatings
Verified
Journal Article
Open access
PDF file
JLJiyong Liu
Jiyong Liu
JSJixing Sun
Jixing Sun
坤张坤 张
坤 张
YLYide Liu
Yide Liu
FTFusheng Tian
Fusheng Tian
WCWang Chen
Wang Chen
Arresters on electric multiple units (EMUs) usually experience premature aging under a high-frequency voltage and impulse current. In addition, they lead to overheating faults when subjected to the high-frequency overvoltage of electric railways. This research investigates the aging behavior of arresters when subjected to overvoltage and an impact current. An analysis was conducted on the impact of the aging duration at 1 mA and the frequency of overvoltage on a lightning arrester’s outer-layer components. The results show that the 1 mA DC reference voltage of the MOA sheet decreased, and the leakage current significantly increased at a 0.75 DC reference voltage through the aging of high-frequency voltage, and the duration of the applied voltage and the voltage bearing rate had similar effects on the two parameters. After aging, the Co and Bi elements on the surface of zinc oxide decreased and migrated to the depletion layer, resulting in a decrease in the dispersion characteristics of the zinc oxide agglomerate surface. Under the impulse voltage, the thermal stress on the surface of the zinc oxide increased, resulting in the damage to the zinc oxide grains, which aggravated the thermal stress concentration and reduced the performance of the zinc oxide. This study reveals the deterioration mechanism of high-frequency voltage- and impulse current gap-modulated MOA materials and provides a theoretical basis and data support for the development of and monitoring methods for new lightning arresters.

25 December 2022 in Coatings
Verified
Journal Article
Open access
PDF file
Jixing SunJixing Sun
Jixing Sun
坤张坤 张
坤 张
KHKaixuan Hu
Kaixuan Hu
JLJiyong Liu
Jiyong Liu
YTYu Tian
Yu Tian
SYShengchun Yan
Shengchun Yan
Accidents always occur in gas-insulated switchgears (GIS) and gas-insulated lines (GIL) since filmed joint electrodes are produced when internal gases react with the electrode’s surface when there is a discharge or when internal electricals overheat. To solve the problem, this paper analyzed the evolution of elements on the contact electrode. The reaction of the SF6 and electrode’s surface under breakdown currents and overheating conditions was obtained, and the discharge time and discharge current effects upon the transfer of the element were proposed. It was found that the mobility of the F element on the electrode’s surface typically increases after electrical heating. The number of interruptions and short-circuit currents are important factors affecting the transfer of the F element to the electrode. The flashover current is the essential factor that accelerates the transfer of the F element to insulating materials. Frequent switching is a main factor that accelerates the transfer of the F element to the contact. It was also found that Al has little correlations with the breaking process, and metal fluorides become the main components on the electrode’s surface under discharge heating. The research provides a theoretical basis and data support for GIS/GIL surface optimization treatments and the improvement of fault detection methods.

24 February 2023 in Coatings
Verified
Journal Article
Open access
PDF file
JSJixing Sun
Jixing Sun
FYfan yongzhi
fan yongzhi
坤张坤 张
坤 张
JLJiyong Liu
Jiyong Liu
XWXin Wang
Xin Wang
SYShengchun Yan
Shengchun Yan
High-frequency overvoltage generated in railways results in explosions of Electric Multiple Units’ (EMUs) arrestors. To solve this problem, the leakage current characteristics and heat transfer process of high-gradient MOA plates under high-frequency overvoltage has been studied. The leakage current characteristics of arrestor plates under high-frequency voltage was obtained and the element distribution has been analyzed. Heat transfer distribution and the thermal properties of the Metal Oxide Arrestor (MOA) have been modelled. According to the results, for a given voltage, the higher the harmonic frequency, the greater the leakage current of the arrestor valve plate, and the greater the resistive component of the leakage current. The Zn and O elements in high-gradient MOA plates are more uniform. Under the same leakage current as conventional ones, the undertake voltage of a high-gradient MOA plate will increase by 10%. Longtime high-order harmonic action will still significantly improve the core rod temperature when MOA plates are coated. The temperature rise in the power supply section of EMUs during operation is roughly 35 °C. This result will provide a foundation and supporting data for the applicability of high-gradient valve plates in railroads and coating improvements for traditional arrestor plates.

29 February 2024 in Coatings
Verified
Journal Article
Open access
PDF file
JSJixing Sun
Jixing Sun
CSChenxi Shao
Chenxi Shao
坤张坤 张
坤 张
JLJiyong Liu
Jiyong Liu
SYShengchun Yan
Shengchun Yan
YZYan Zhang
Yan Zhang
Circuit breakers, affected by multiple lightning strikes after the breaker has been tripped, can break down again, which will reduce the life of the circuit breaker and threaten the stable operation of the power system. Aiming at this problem, this research obtained the temperature diffusion process of the inrush current process of the circuit breaker’s opening and breaking, using the Schlieren technique combined with existing image recognition technology to obtain the temperature characteristics of the airflow in the air gap of the contact, as well as the characteristics of the flow of air itself. The results of the study show that the circuit breaker breakdown process generates a shock wave with a velocity approximately equal to the speed of sound under the same conditions. The maximum velocity of the airflow boundary diffusion is about one-quarter of the speed of sound under the same condition, and it decays very fast, reducing to the airflow drift velocity within 10 ms after breakdown. The maximum temperature of the thermals is concentrated between 6000 K and 8000 K, and the temperature change is approximately inversely proportional to the square of the time. This research provides the basis for the design of a circuit breaker’s contact structure, opening speed optimization method, interrupter chamber, and insulation design optimization.

18 November 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
JSJixing Sun
Jixing Sun
坤张坤 张
坤 张
YLYide Liu
Yide Liu
SYSile Yang
Sile Yang
JTJiuding Tan
Jiuding Tan
The high-voltage system of high-speed trains is now in the form of combined electrical apparatus, which has a high probability of insulation breakdown due to frequent overvoltage during operation. To solve this issue, an electric field simulation model of the high-voltage combined electrical system was established, the electric field distribution of the high-voltage box electrode under overvoltage operating conditions was analyzed, and the air breakdown characteristics under field action were studied. The study shows that under overvoltage conditions, the electric field intensity near the small electrodes of the combined electrical unit is higher than the air breakdown field intensity, and the statistical time delay is approximately 5.94 μs when 150 kV voltage is applied. When the size of the connected electrode is doubled and 150 kV voltage is applied, the statistical delay is about 7.20 μs and the probability of discharge is reduced. Further installation of an insulating partition between the circuit breaker and the ground switch completely solved the problem of low electrical gap insulation capacity. Combined with impulse withstand tests, the effectiveness of the electrode size design was verified, and the research results provided theoretical support for the miniaturization and high-reliability design of vehicle-mounted high-voltage electrical appliances.

22 March 2026 in Coatings
Verified
Journal Article
Open access
PDF file
JSJixing Sun
Jixing Sun
YLYide Liu
Yide Liu
DLDong Lei
Dong Lei
JWJiawei Wang
Jiawei Wang
TXTong Xing
Tong Xing
JTJiuding Tan
Jiuding Tan
With the rapid development of electrified railways in high-altitude regions, section insulators in catenary systems frequently experience gap breakdown and surface flashover under low atmospheric pressure conditions, posing serious threats to safe train operation. This paper investigates the discharge mechanisms of section insulators in high-altitude environments and conducts research on discharge characteristics under extremely non-uniform electric fields, along with structural optimization. First, the physical mechanisms of gap discharge and surface flashover in section insulators are analyzed. A three-dimensional electric field simulation model of the section insulator is established, and numerical analysis is performed to reveal the electric field distribution characteristics. The results indicate that the electric field is predominantly concentrated at the junction between metal electrodes and insulators, as well as at the tip of the arcing horn. The local maximum field strength reaches 3.84 × 105 V/m, exceeding the corona inception field strength of air, which readily induces discharge. Subsequently, power frequency and lightning impulse discharge tests are conducted in both plain region and regions at an altitude of 4300 m. The results show that under high-altitude conditions, the power frequency breakdown voltage decreases by 28%, and the 50% lightning impulse breakdown voltage decreases by 42%. The discharge voltages under standard atmospheric conditions are obtained through correction. Finally, optimization schemes involving arcing horn structural modification and surface coating application are proposed. Adjusting the arcing horn angle to 55° and adding a grading ring structure with a radius of 70 mm reduces the local maximum field strength by 26%. After applying an RTV insulating coating, the field strength at the junction decreases by 35.9%, effectively enhancing the insulation performance of section insulators in high-altitude regions.