Yide Liu

Dr. Yide Liu


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 March 2026 in Coatings
Verified
Journal Article
Open access
PDF file
JSJixing Sun
Jixing Sun
YLYide Liu
Yide Liu
DLDong Lei
Dong Lei
JWJiawei Wang
Jiawei Wang
TXTong Xing
Tong Xing
JTJiuding Tan
Jiuding Tan
With the rapid development of electrified railways in high-altitude regions, section insulators in catenary systems frequently experience gap breakdown and surface flashover under low atmospheric pressure conditions, posing serious threats to safe train operation. This paper investigates the discharge mechanisms of section insulators in high-altitude environments and conducts research on discharge characteristics under extremely non-uniform electric fields, along with structural optimization. First, the physical mechanisms of gap discharge and surface flashover in section insulators are analyzed. A three-dimensional electric field simulation model of the section insulator is established, and numerical analysis is performed to reveal the electric field distribution characteristics. The results indicate that the electric field is predominantly concentrated at the junction between metal electrodes and insulators, as well as at the tip of the arcing horn. The local maximum field strength reaches 3.84 × 105 V/m, exceeding the corona inception field strength of air, which readily induces discharge. Subsequently, power frequency and lightning impulse discharge tests are conducted in both plain region and regions at an altitude of 4300 m. The results show that under high-altitude conditions, the power frequency breakdown voltage decreases by 28%, and the 50% lightning impulse breakdown voltage decreases by 42%. The discharge voltages under standard atmospheric conditions are obtained through correction. Finally, optimization schemes involving arcing horn structural modification and surface coating application are proposed. Adjusting the arcing horn angle to 55° and adding a grading ring structure with a radius of 70 mm reduces the local maximum field strength by 26%. After applying an RTV insulating coating, the field strength at the junction decreases by 35.9%, effectively enhancing the insulation performance of section insulators in high-altitude regions.

18 November 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
JSJixing Sun
Jixing Sun
坤张坤 张
坤 张
YLYide Liu
Yide Liu
SYSile Yang
Sile Yang
JTJiuding Tan
Jiuding Tan
The high-voltage system of high-speed trains is now in the form of combined electrical apparatus, which has a high probability of insulation breakdown due to frequent overvoltage during operation. To solve this issue, an electric field simulation model of the high-voltage combined electrical system was established, the electric field distribution of the high-voltage box electrode under overvoltage operating conditions was analyzed, and the air breakdown characteristics under field action were studied. The study shows that under overvoltage conditions, the electric field intensity near the small electrodes of the combined electrical unit is higher than the air breakdown field intensity, and the statistical time delay is approximately 5.94 μs when 150 kV voltage is applied. When the size of the connected electrode is doubled and 150 kV voltage is applied, the statistical delay is about 7.20 μs and the probability of discharge is reduced. Further installation of an insulating partition between the circuit breaker and the ground switch completely solved the problem of low electrical gap insulation capacity. Combined with impulse withstand tests, the effectiveness of the electrode size design was verified, and the research results provided theoretical support for the miniaturization and high-reliability design of vehicle-mounted high-voltage electrical appliances.

25 June 2026 in Applied Sciences
Verified
Journal Article
Open access
PDF file
JSJixing Sun
Jixing Sun
汪汪汪倩冰 汪
汪倩冰 汪
ZDZhao Dong
Zhao Dong
YLYide Liu
Yide Liu
ZYZhang Yanhui
Zhang Yanhui
YHYuming Huo
Yuming Huo
Railway transportation networks increasingly share constrained corridors with transmission lines, buried pipelines, and other linear infrastructure. Electromagnetic interference in these corridors is important for safe railway planning and operation, particularly when nearby high-voltage lines cross oil and gas pipelines. This paper investigates transmission-line-induced pipeline potential under crossing conditions in the Zhangbei region. The CDEGS moment-method framework is applied with locally refined segmentation in the crossing regions, and an electromagnetic coupling model for multiple-crossing transmission line-oil and gas pipeline systems is established. The qualitative effects of crossing angle and parallel length on pipeline potential were obtained under both normal operating conditions and single-phase ground fault transient conditions. The results show that induced voltage decreases nonlinearly as the crossing angle increases and rises markedly with crossing length. The contribution of ground potential rise during transient processes to pipeline potential is significantly greater than that during steady-state processes. Installing zinc ribbons as a drainage measure can reduce the pipeline-to-ground voltage. However, supplementary mitigation measures may still be required under severe interference conditions. These findings are relevant to railway transportation because railway corridors often coexist with transmission lines and buried pipelines, making coordinated electromagnetic compatibility assessment essential for infrastructure safety and operational reliability. The proposed framework supports corridor planning, risk assessment, and protective design for railway-related infrastructure in complex shared corridors.