With the rapid development of electrified railways in high-altitude regions, section insulators in catenary systems frequently experience gap breakdown and surface flashover under low atmospheric pressure conditions, posing serious threats to safe train operation. This paper investigates the discharge mechanisms of section insulators in high-altitude environments and conducts research on discharge characteristics under extremely non-uniform electric fields, along with structural optimization. First, the physical mechanisms of gap discharge and surface flashover in section insulators are analyzed. A three-dimensional electric field simulation model of the section insulator is established, and numerical analysis is performed to reveal the electric field distribution characteristics. The results indicate that the electric field is predominantly concentrated at the junction between metal electrodes and insulators, as well as at the tip of the arcing horn. The local maximum field strength reaches 3.84 × 105 V/m, exceeding the corona inception field strength of air, which readily induces discharge. Subsequently, power frequency and lightning impulse discharge tests are conducted in both plain region and regions at an altitude of 4300 m. The results show that under high-altitude conditions, the power frequency breakdown voltage decreases by 28%, and the 50% lightning impulse breakdown voltage decreases by 42%. The discharge voltages under standard atmospheric conditions are obtained through correction. Finally, optimization schemes involving arcing horn structural modification and surface coating application are proposed. Adjusting the arcing horn angle to 55° and adding a grading ring structure with a radius of 70 mm reduces the local maximum field strength by 26%. After applying an RTV insulating coating, the field strength at the junction decreases by 35.9%, effectively enhancing the insulation performance of section insulators in high-altitude regions.
The high-voltage system of high-speed trains is now in the form of combined electrical apparatus, which has a high probability of insulation breakdown due to frequent overvoltage during operation. To solve this issue, an electric field simulation model of the high-voltage combined electrical system was established, the electric field distribution of the high-voltage box electrode under overvoltage operating conditions was analyzed, and the air breakdown characteristics under field action were studied. The study shows that under overvoltage conditions, the electric field intensity near the small electrodes of the combined electrical unit is higher than the air breakdown field intensity, and the statistical time delay is approximately 5.94 μs when 150 kV voltage is applied. When the size of the connected electrode is doubled and 150 kV voltage is applied, the statistical delay is about 7.20 μs and the probability of discharge is reduced. Further installation of an insulating partition between the circuit breaker and the ground switch completely solved the problem of low electrical gap insulation capacity. Combined with impulse withstand tests, the effectiveness of the electrode size design was verified, and the research results provided theoretical support for the miniaturization and high-reliability design of vehicle-mounted high-voltage electrical appliances.
Existing methods for arrester analysis mainly rely on static voltage sharing and steady-state parameters and thus cannot adequately represent transient responses under broadband excitation. To address this, a dynamic arrester model is established that considers the coupled electrical, thermal, and frequency characteristics of ZnO. Under power-frequency AC excitation containing broadband harmonics and fast-front impulses, the axial potential distribution and transient temperature rise in the varistor column are analyzed. On this basis, formulas for key degradation parameters under harmonic conditions are developed and verified by electrothermal experiments. The results indicate that under transient excitation, the peaks of potential and temperature rise tend to concentrate near the bottom of the varistor column; over a longer time scale, the peak region gradually shifts toward the middle of the column. This trend becomes more evident as frequency and wavefront steepness increase. Finally, an improved measurement parameter based on gradient potential ΔU and transient temperature rise ΔQ is proposed, providing a reference for arrester evaluation under broadband conditions.