The limitation of fossil fuel sources and negative environmental impact persuade scientists around the world to find a solution. One possible solution is by using renewable fuel to replace fossil fuel with an inexpensive, fast, and effective production process. The objective of this study is to investigate the biodiesel production from crude Reutealis trisperma oil using the conventional and the ultrasonic bath stirrer method through the esterification and transesterification process. The result shows that the most effective reaction time with an optimum condition for the esterification and transesterification of Reutealis trisperma oil is at 2 h 30 min by using the ultrasonic bath stirrer method. The optimum conditions at a temperature of 55 °C for the esterification and at 60 °C for transesterification with 2% (v/v) of sulphuric acid with catalyst concentration of 0.5 wt.% were a methanol-to-oil ratio of 60%, and agitation speed of 1000 rpm. This optimum condition gives the highest yield of 95.29% for the Reutealis trisperma biodiesel. The results showed that the ultrasonic bath stirrer method had more effect on the reaction time needed than using the conventional method and reduced half of the conventional method reaction time. Finally, the properties of Reutealis trisperma biodiesel fulfilled the ASTM D6751 and EN 14214 biodiesel standards with density, 892 kg/m3; pour point, −2 °C; cloud point, −1 °C; flash point, 206.5 °C; calorific value, 40.098 MJ/kg; and acid value, 0.26 mg KOH/g.
Geothermal heat exchangers (GHEs) represent a buried pipe system, which can be utilised to harness renewable thermal energy stored in the ground to improve the efficiency of heating and cooling systems. Two basic arrangements of GHEs have been widely used: vertical and horizontal. Vertical GHEs generally have a better performance in comparison with the horizontal arrangement, and these systems are particularly suitable for confined spaces. Nevertheless, the main technical challenge associated with GHEs, for either the vertical or the horizontal arrangement, is the performance deterioration associated with an increase in the operation times during summer or winter seasons. In this paper, a combined horizontal-vertical GHE arrangement is proposed to address the current challenges. The combined GHE arrangement can be operated in five different modes, corresponding to different thermal loading conditions. These five operation modes of the combined GHE are analysed based on the transient finite difference models previously developed for the horizontal and vertical arrangements. The simulation results reveal that for the single operation mode (horizontal or vertical only), the vertical GHE performs better than the horizontal GHE due to relatively stable ground temperature deep down. While, for the combined operation mode, the series operations (horizontal to vertical or vertical to horizontal) of the GHE are superior to the split mode. It is found that the effect of the fluid mass flow rate ratio is trivial on the heat dissipation of the split mode GHE. The highest heat transfer rate in the split flow operational mode is rendered by the ratio of the mass flow rate of 40% horizontal and 60% vertical. In addition, the climate condition has more effect on GHE’s performance and the increase of the fluid flow rate it can enhance the amount of energy released by the GHE.
The air conditioning system is the most common way to provide comfortable room temperature for its inhabitants. However, the energy required for its operation is extremely high and cost-intensive. Therefore, a more efficient HVAC system with a lower energy consumption is desirable. The experimental results and performance analysis demonstrated that the outlet air temperature through the evaporator side of HPHE (precooling) has the potential to save some amount of energy utilizing an HVAC system equipped with HPHE. This research aims to study the performance of HPHE with the precooling process applied in commercial room HVAC system applications. This research on the utilization of HPHE for heat recovery in air conditioning systems was carried out with variations in temperature of fresh air intake ranging between 32–42 ℃. The airflow speed was set constant at 1.0 m/s. This experiment demonstrated the highest effectiveness at a value of 21%. The HPHE heat recovery analysis results show that the best heat recovery performance is achieved when the fresh air intake temperature exceeds the exhaust air leaving the room. The phenomenon was compared at a low fresh air intake temperature of 32 ℃, which succeeded in recovering 0.05 W, and when the temperature rose to 42 ℃, 0.21 W was recovered.
1 October 2021 in Journal of Ecological Engineering
Shipyard development in Kutaraja Fishing Port is important to improve the port performance. Studies related to shipyards are mainly focused on their productivity, facility layout, production capacity, and management and planning. Meanwhile, there are still limited studies related to the...
31 October 2019 in European Journal of Engineering and Technology Research
Thermal energy storage using Phase Change Materials (PCM) is now widely applied to wall buildings. In general, PCM which is used for applications on building walls is organic PCM and has temperature range from 0℃ to 65oC. Beef tallow and coconut oil is a type of organic PCM known as Bio PCM needs to characterize by using the T-History Method. The T-History method is more accurate than Differential Scanning Calorimetry (DSC) and Differential Thermal Analysis (DTA). This study aimed to determine the thermal properties of beef tallow/coconut oil PCM using the T-History method. The beef tallow and coconut oil as bio PCM material was used in this study with the variation are respectively: 100%, 70+30%, 60+40%, and 50+50%. Tests are carried out using the T-History method. From the results of testing and analysis obtained supercooling temperature, melting temperature, specific heat, and latent heat for bio PCM beef tallow/coconut oil. The effect of adding coconut oil mixture to beef tallow caused a decrease in melting temperature and supercooling temperature, while the specific heat and latent heat of bio PCM of beef tallow/coconut oil ranged from 2.96-2.19 kJ/kg.℃ and 101.05-72.32 kJ/kg. The result obtained that this bio PCM material of cow beef tallow/coconut oil can apply, as additional material in wall building applications.