The application possibilities of austenitic stainless steels in high friction, abrasion, and sliding wear conditions are limited by their inadequate hardness and tribological characteristics. In order to improve these properties, the thermochemical treatment of their surface by plasma nitriding is suitable. This article is focused on the corrosion resistance of conventionally plasma-nitrided AISI 304 stainless steel (530 °C, 24 h) in 0.05 M and 0.5 M sodium chloride solutions at room temperature (20 ± 3 °C), tested by potentiodynamic polarization and electrochemical impedance spectroscopy. Optical microscopy, scanning electron microscopy, energy-dispersive X-ray spectroscopy, and X-ray photoelectron spectroscopy are used for nitrided layer characterization. The experiment results confirmed the plasma-nitrided layer formation of increased micro-hardness related to the presence of Cr2N chromium nitrides and higher surface roughness compared to the as-received state. Both of the performed independent electrochemical corrosion tests point to a significant reduction in corrosion resistance after the performed plasma nitriding, even in a solution with a very low chloride concentration (0.05 mol/L).
This article deals with the influence of plasma nitriding and sensitization on the microstructure and microhardness of AISI 304 austenitic steel. The microstructure of AISI 304 austenitic steel in all states was observed on a Neophot 32 optica...
The paper is aimed at establishing knowledge of the failure mechanisms and plastic behaviour of austenitic steel AISI 304 in the initial state under different loading conditions. Microstructural analysis was performed on a light microscope Neophot 32. AISI 304 austenitic steel has a microstructure formed by a large number of polyhedral austenite grains of different sizes. The steel microstructure, mechanical and fatigue properties, and areas of the plastic zone after the bending impact test were investigated. The surface hardness of samples was measured on a Zwick Roell ZHVµ microhardness measuring device using the Vickers method. After the bending impact test, fractures were formed with significant deformation with a typical pit morphology. The fatigue test, performed on a Zwick Roell resonant pulsator, monitored the plastic deformation causing changes in mechanical properties. Finally, fractographic evaluations of the fracture surfaces were performed on a Tescan Vega LMUII scanning electron microscope. The result of the work will demonstrate the differences in material behaviour under both static and cyclic loading.
The application possibilities of austenitic stainless steels in high friction, abrasion and sliding wear conditions are limited by their inadequate hardness and tribological characteristics. In order to improve these properties, thermochemical treatment of their surface by plasma nitriding is suitable. This article is focused on corrosion resistance of the conventionally plasma nitrided AISI 304 stainless steel (530 °C, 24 hours) in 0.05 M and 0.5 M sodium chloride solutions at room temperature (20 ± 3 °C), tested by potentiodynamic polarization and electrochemical impedance spectroscopy. The optical microscopy, scanning electron microscopy, energy-dispersive X-ray spectroscopy and X-ray photoelectron spectroscopy are used for the nitrided layer characterization. The experiment results point to a significant reduction in corrosion resistance after performed plasma nitriding even in a solution with a very low chloride concentration (0.05 mol/L).
1 September 2023 in Materials Research Proceedings
A lot of emphasis is currently being paid to research into how hydrogen affects the mechanical properties of advanced high-strength (AHS) steels. The use of AHS steels in the chemical industry and nuclear technology is heavily influenced by the mechanical properties that result from the impact of hydrogen. Hydrogen, an interstitial element, alters fracture behavior and causes the material to fail earlier than it should. The greatest danger occurs after hydrogen has been absorbed when it diffuses and accumulates into defects such grain boundaries, dislocations, and phase boundaries. The crystal structure of the steel enlarges due to tensile stresses, which increases hydrogen diffusion. Cold forming creates a multitude of components, and even a small amount of hydrogen absorption could result in significant residual stresses in the material. The steel can experience a significant reduction in mechanical properties, strength, and ductility up to fracture at a critical hydrogen concentration level. It is impossible to preventively remove components that have been harmed by hydrogen before they are utilized, which is the primary issue with hydrogen embrittlement from a safety perspective.
Hydrogen embrittlement involves the interaction between hydrogen and the microstructure of metals, which can lead to an alarming loss of mechanical properties. For advanced high-strength (AHS) steel S960MC grade, which finds application in fie...