Martin Slezak

Mr. Martin Slezak

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 August 2024 in Materials
Verified
Journal Article
Open access
PDF file
VZViera Viera Zatkalíková
Viera Viera Zatkalíková
PDPetra Drímalová
Petra Drímalová
KBKatarzyna Balin
Katarzyna Balin
MSMartin Slezak
Martin Slezak
LMLenka Markovičová
Lenka Markovičová
The application possibilities of austenitic stainless steels in high friction, abrasion, and sliding wear conditions are limited by their inadequate hardness and tribological characteristics. In order to improve these properties, the thermochemical treatment of their surface by plasma nitriding is suitable. This article is focused on the corrosion resistance of conventionally plasma-nitrided AISI 304 stainless steel (530 °C, 24 h) in 0.05 M and 0.5 M sodium chloride solutions at room temperature (20 ± 3 °C), tested by potentiodynamic polarization and electrochemical impedance spectroscopy. Optical microscopy, scanning electron microscopy, energy-dispersive X-ray spectroscopy, and X-ray photoelectron spectroscopy are used for nitrided layer characterization. The experiment results confirmed the plasma-nitrided layer formation of increased micro-hardness related to the presence of Cr2N chromium nitrides and higher surface roughness compared to the as-received state. Both of the performed independent electrochemical corrosion tests point to a significant reduction in corrosion resistance after the performed plasma nitriding, even in a solution with a very low chloride concentration (0.05 mol/L).

12 July 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
VZViera Viera Zatkalíková
Viera Viera Zatkalíková
PDPetra Drímalová
Petra Drímalová
KBKatarzyna Balin
Katarzyna Balin
MSMartin Slezak
Martin Slezak
LMLenka Markovičová
Lenka Markovičová
The application possibilities of austenitic stainless steels in high friction, abrasion and sliding wear conditions are limited by their inadequate hardness and tribological characteristics. In order to improve these properties, thermochemical treatment of their surface by plasma nitriding is suitable. This article is focused on corrosion resistance of the conventionally plasma nitrided AISI 304 stainless steel (530 °C, 24 hours) in 0.05 M and 0.5 M sodium chloride solutions at room temperature (20 ± 3 °C), tested by potentiodynamic polarization and electrochemical impedance spectroscopy. The optical microscopy, scanning electron microscopy, energy-dispersive X-ray spectroscopy and X-ray photoelectron spectroscopy are used for the nitrided layer characterization. The experiment results point to a significant reduction in corrosion resistance after performed plasma nitriding even in a solution with a very low chloride concentration (0.05 mol/L).

6 December 2023 in Manufacturing Technology
Verified
Journal Article
Open access
PDF file
VCVeronika Chvalníková
Veronika Chvalníková
MUMilan Uhríčik
Milan Uhríčik
PPPeter Palček
Peter Palček
MSMartin Slezak
Martin Slezak
LŠLukáš Šikyňa
Lukáš Šikyňa
PDPetra Drímalová
Petra Drímalová
The paper is aimed at establishing knowledge of the failure mechanisms and plastic behaviour of austenitic steel AISI 304 in the initial state under different loading conditions. Microstructural analysis was performed on a light microscope Neophot 32. AISI 304 austenitic steel has a microstructure formed by a large number of polyhedral austenite grains of different sizes. The steel microstructure, mechanical and fatigue properties, and areas of the plastic zone after the bending impact test were investigated. The surface hardness of samples was measured on a Zwick Roell ZHVµ microhardness measuring device using the Vickers method. After the bending impact test, fractures were formed with significant deformation with a typical pit morphology. The fatigue test, performed on a Zwick Roell resonant pulsator, monitored the plastic deformation causing changes in mechanical properties. Finally, fractographic evaluations of the fracture surfaces were performed on a Tescan Vega LMUII scanning electron microscope. The result of the work will demonstrate the differences in material behaviour under both static and cyclic loading.

22 December 2023 in Manufacturing Technology
Verified
Journal Article
Open access
PDF file
MSMartin Slezak
Martin Slezak
MUMilan Uhríčik
Milan Uhríčik
PPPeter Palček
Peter Palček
VCVeronika Chvalníková
Veronika Chvalníková
PDPetra Drímalová
Petra Drímalová
LŠLukáš Šikyňa
Lukáš Šikyňa
This article deals with the influence of plasma nitriding and sensitization on the microstructure and microhardness of AISI 304 austenitic steel. The microstructure of AISI 304 austenitic steel in all states was observed on a Neophot 32 optica...

23 February 2024 in Manufacturing Technology
Verified
Journal Article
Open access
PDF file
PDPetra Drímalová
Petra Drímalová
Frantisek NovyFrantisek Novy
Frantisek Novy
MUMilan Uhríčik
Milan Uhríčik
PVPetra Váňová
Petra Váňová
LŠLukáš Šikyňa
Lukáš Šikyňa
MSMartin Slezak
Martin Slezak
Hydrogen embrittlement involves the interaction between hydrogen and the microstructure of metals, which can lead to an alarming loss of mechanical properties. For advanced high-strength (AHS) steel S960MC grade, which finds application in fie...

1 December 2024 in System Safety: Human - Technical Facility - Environment
Verified
Journal Article
Open access
PDF file
VZViera Viera Zatkalíková
Viera Viera Zatkalíková
LMLenka Markovičová
Lenka Markovičová
MUMilan Uhríčik
Milan Uhríčik
MSMartin Slezak
Martin Slezak
Austenitic stainless steels are highly corrosion-resistant in common oxidation environments. However, aggressive chloride-containing solutions can evoke local corrosion, which performs an important risk in the safe use of these materials. This research deals with the effect of the solution annealing (1050 °C, 15 min) on the electrochemical parameters of AISI 304 and AISI 316L stainless steels. Corrosion resistance of the solution-annealed specimens is evaluated and compared to the as received specimens by the potentiodynamic polarization test performed in 1M pH neutral NaCl solution at the 20 ± 3 °C temperature. The obtained results did not clearly confirm the positive effect of solution annealing on corrosion resistance in the given aggressive solution. Although the pitting potentials indicating higher pitting corrosion resistance increased, the kinetics of the corrosion process intensified.