André Fernando Schiochet

André Fernando Schiochet


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 October 2024 in Energies
Verified
Journal Article
Open access
PDF file
ASAndré Fernando Schiochet
André Fernando Schiochet
PMPaulo Roberto Duailibe Duailibe Duailibe Monteiro
Paulo Roberto Duailibe Duailibe Duailibe Monteiro
TBThiago Trezza Borges
Thiago Trezza Borges
JFJoão Alberto Passos Filho
João Alberto Passos Filho
JOJanaina Goncalves de Oliveira
Janaina Goncalves de Oliveira
The growing integration of renewable energy sources, such as photovoltaic and wind systems, into energy grids has underscored the need for reliable control mechanisms to mitigate the inherent intermittency of these sources. According to the Brazilian grid operator (ONS), there have been cascading disconnections in renewable energy distributed systems (REDs) in recent years, highlighting the need for robust control models. This article addresses this issue by presenting the validation of an active power ramp rate control (PRRC) function for a PV plant coupled with a Battery Energy Storage System (BESS) using WECC generic models. The proposed model underwent rigorous validation over an extended analysis period, demonstrating good accuracy using the Root Mean Squared Error (RMSE) and an R-squared (R2) metrics for the active power injected at the Point of Connection (POI), PV active power, and BESS State of Charge (SOC), providing valuable insights for medium and long-term analyses. The ramp rate control module was implemented within the plant power controller (PPC), leveraging second-generation Renewable Energy Systems (RES) models developed by the Western Electricity Coordination Council (WECC) as a foundational framework. We conducted simulations using the Anatem software, comparing the results with real-world data collected at 100 ms to 1000 ms intervals from a PV plant equipped with a BESS in Brazil. The proposed model underwent rigorous validation over an extended analysis period, with the presented results based on two days of measurements. The positive sequence model used to represent this control demonstrated good accuracy, as confirmed by metrics such as the Root Mean Squared Error (RMSE) and R-squared (R2). Furthermore, the article underscores the critical role of accurately accounting for the power sampling rate when calculating the ramp rate.

18 October 2023 in Anais Do Vi Simpósio Brasileiro de Sistemas Elétricos
Verified
Conference Paper
Open access
PDF file
ASAndré Fernando Schiochet
André Fernando Schiochet
EVEduardo de Castro Vieira
Eduardo de Castro Vieira
FBFábio Pereira Costa Brilhante
Fábio Pereira Costa Brilhante
LFLuiz Fernando Almeida Fontenele
Luiz Fernando Almeida Fontenele
PCPaulo Fernando Santos Dias de Carvalho
Paulo Fernando Santos Dias de Carvalho
Danilo de Barros HerreraDanilo de Barros Herrera
Danilo de Barros Herrera
A geração fotovoltaica apresenta a característica de ser intermitente e não-despachável, de forma que não apresenta uma estabilidade de geração. Os sistemas de armazenamento de energia fornecem a capacidade de gerenciamento da energia, através da prestação de serviços energéticos e de serviços ancilares. Com o intuito de melhorar o fluxo potência, estabilidade e características de qualidade de rede, se propõe a combinação de um sistema fotovoltaico com um sistema de armazenamento de energia. Este artigo apresenta o desenvolvimento e implantação de um sistema de armazenamento de energia com baterias (SAEB) de Íons de Lítio, com potência de 1 MW e capacidade de 0,43 MWh, associado à Usina Fotovoltaica Alto do Rodrigues (UFV-AR). A UFV-AR tem uma potência instalada de 1,1 MW e o objetivo do SAEB é: realizar o controle de rampas de geração para atenuar a intermitência da usina fotovoltaica, possibilitar os serviços de deslocamento de energia e realizar o controle da potência injetada no sistema (estratégia chamada de shaping). Este projeto foi desenvolvido no âmbito da chamada de projetos de P&D (Pesquisa e Desenvolvimento) nº 021/2016 da ANEEL: Projeto Estratégico: “Arranjos Técnicos e Comerciais para a Inserção de Sistemas de Armazenamento de Energia no Setor Elétrico Brasileiro, cadastrado na agência sob o código PD-00553-0046/2016.