The growing integration of renewable energy sources, such as photovoltaic and wind systems, into energy grids has underscored the need for reliable control mechanisms to mitigate the inherent intermittency of these sources. According to the Brazilian grid operator (ONS), there have been cascading disconnections in renewable energy distributed systems (REDs) in recent years, highlighting the need for robust control models. This article addresses this issue by presenting the validation of an active power ramp rate control (PRRC) function for a PV plant coupled with a Battery Energy Storage System (BESS) using WECC generic models. The proposed model underwent rigorous validation over an extended analysis period, demonstrating good accuracy using the Root Mean Squared Error (RMSE) and an R-squared (R2) metrics for the active power injected at the Point of Connection (POI), PV active power, and BESS State of Charge (SOC), providing valuable insights for medium and long-term analyses. The ramp rate control module was implemented within the plant power controller (PPC), leveraging second-generation Renewable Energy Systems (RES) models developed by the Western Electricity Coordination Council (WECC) as a foundational framework. We conducted simulations using the Anatem software, comparing the results with real-world data collected at 100 ms to 1000 ms intervals from a PV plant equipped with a BESS in Brazil. The proposed model underwent rigorous validation over an extended analysis period, with the presented results based on two days of measurements. The positive sequence model used to represent this control demonstrated good accuracy, as confirmed by metrics such as the Root Mean Squared Error (RMSE) and R-squared (R2). Furthermore, the article underscores the critical role of accurately accounting for the power sampling rate when calculating the ramp rate.
Para avaliar os efeitos dos recursos energéticos distribuídos (DER) na rede, são necessários modelos robustos para os inversores de frequência, com a capacidade de representar adequadamente os impactos e as respostas aos modos de controlo. A fim de utilizar modelos menos complexos e atualizados, além de ser representativo em estudos de estabilidade, um modelo genérico de sequência positiva foi desenvolvido no programa CEPEL ANATEM baseado no modelo EPRI. O modelo foi simulado nas mesmas condições de operação que os testes do EPRI. Um sistema com uma fonte emulando as curvas de tensão e frequência (tensão de play-in e frequência de play-in) foi considerado. Os resultados demonstram a validação do modelo, obtendo resultados semelhantes aos testes do EPRI. O modelo apresentado é recomendado para avaliar o impacto de DERs conectados no sistema de granel, verificando o desempenho de proteções e desconexões e o respectivo efeito no sistema de transmissão.
This paper presents an overview of the implementation of the main wind farms Offshore carried out so far, most of which is in Europe. A summary of the solutions applied and consolidated in the industry, related to the transmission technologies used in the connection of wind farms Offshore to existing power grids is shown. Some of the topics covered are: the type of transmission used (direct or alternating current), the technology adopted in the converter bridges in the enterprises that chose to use direct current transmission (VSC) and its advantages, the magnitude of the distances and transmission capacities achieved and the technologies for compensation of reactives. In addition, regulatory and economic aspects related to the connection of these wind farms to the transmission grid are also addressed. Finally, a case study is presented in which several alternatives for the connection of two parks are compared Offshore to the transmission system from an economic point of view. DOI:https://doi.org/10.56238/uniknowindevolp-111
This work, based on [1], presents and discusses the solutions to overvoltages experienced by the medium voltage system (13.8 kV) in an existing refinery resulting from the switching of power transformers supplied by a high voltage system (230 kV) through insulated cables. The analysis demonstrates the influence of the other feeder cables and the transient interaction between them and the switched feeder, due to their high capacitances, leading to the increase of overvoltages to values over the insulation withstand. These overvoltages exhibit high frequency and high amplitude and are primarily transferred from the high voltage side to the medium voltage side mainly through transformer capacitive couplings. This process may lead to insulation breakdown in medium voltage equipment, as confirmed by simulations and practical observations. Solutions for overvoltage mitigation, such as surge arresters and pre-insertion resistors applied to switching circuit breakers, are presented.
RESUMO ESTRUTURADO Este trabalho aborda os conceitos e as implicações da utilização da geração distribuída (GD) fotovoltaica nas redes elétricas de média e baixa tensão. São avaliados os possíveis impactos causados aos reguladores de tensão ao longo destas redes. A análise considerou a variação do nível de geração das GDs em 8 cenários. Nestes cenários serão avaliadas a operação de comutação de TAP em um regulador de linha de distribuição, uma indústria e por último a análise da Fase A de três reguladores. Para isso foram utilizadas simulações através do programa computacional OpenDSS. O primeiro cenário é realizado sem a penetração de GDs e os demais com a penetração das GDs de 50 % e 90 %. Tais análises foram realizadas utilizando o caso teste 8.500 barras do IEEE (Institute of Electrical and Electronics Engineers), disponível na biblioteca do OpenDSS e os resultados são comentados para caracterizar os impactos na tensão da barra. Palavras-chave: Geração distribuída; Regulador de tensão; Estudo de casos; Intermitência fotovoltaica; Qualidade de energia; OpenDSS.