EDISON NOVOA

Mr. EDISON NOVOA

Departamento de Energía Eléctrica, Escuela Politécnica Nacional, Quito, Pichincha, Ecuador
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 November 2025 in Engineering Proceedings
Verified
Conference Paper
Open access
PDF file
EDISON NOVOAEDISON NOVOA
EDISON NOVOA
JCJaime Cristóbal Cepeda
Jaime Cristóbal Cepeda
This paper investigates the role of reactive power support from Distributed Generation (DG) units in improving voltage compliance and maximizing active power injection in medium-voltage distribution networks. Using the IEEE 34-Node Test Feeder as a case study, a simplified single-phase equivalent model was developed, excluding voltage regulators, shunt capacitors, and step-down transformers to focus on the intrinsic voltage behavior of the feeder. An AC Optimal Power Flow (OPF) model was formulated in Pyomo and solved with Interior Point Optimizer (IPOPT) to evaluate two operational scenarios: (i) DG injecting a fixed 1 MW of active power without reactive power support, and (ii) DG injecting the same active power with optimized reactive power dispatch within ±0.5 MVAr, subject to apparent power constraints. Simulation results show that allowing reactive power flexibility increases the number of feasible DG connection points, improves minimum bus voltages, and reduces the occurrence of voltage limit violations. The findings suggest that modest reactive power capabilities can significantly enhance the hosting capacity of radial distribution feeders without requiring costly network reinforcements.

31 July 2021 in Revista Politécnica
Verified
Journal Article
Open access
PDF file
ABAndrés Barahona
Andrés Barahona
JSJaime Salazar
Jaime Salazar
MSMauricio Soria
Mauricio Soria
EDISON NOVOAEDISON NOVOA
EDISON NOVOA
DCDarwin Caina
Darwin Caina
FPFABIAN ERNESTO PÉREZ-YAULI
FABIAN ERNESTO PÉREZ-YAULI
Este artículo presenta el diseño de un sensor autónomo para sistemas de protección eléctrica empleando tecnologías innovadoras que, para su operación, se abastecen de recursos energéticos del medio ambiente y además requieren de un bajo consumo de potencia. El prototipo posee tarjetas electrónicas que operan en cuatro etapas. La primera etapa se encarga de adquirir datos reales de corriente de un sistema eléctrico de prueba. En la segunda etapa, mediante el preprocesamiento y análisis de datos, se detectan perturbaciones en la señal de corriente del sistema eléctrico de prueba. La tercera etapa comprende la comunicación de datos por radiofrecuencia, la cual se ejecuta solo cuando su algoritmo de procesamiento ha detectado valores de corriente anormales, caso contrario, la transmisión de información se mantiene deshabilitada y con el dispositivo operando en modo de ultra bajo consumo de energía. La última etapa del sensor autónomo se encarga de proveerlo de energía mediante baterías de litio-polímero y paneles fotovoltaicos que aprovechan el uso y almacenamiento de la energía solar. Finalmente, para probar el sensor diseñado, se realizan varias pruebas de funcionamiento y se analizan los resultados obtenidos.

30 January 2026 in Revista Técnica "Energía"
Verified
Journal Article
Open access
PDF file
DTDylan Torres
Dylan Torres
PGPatricia Gavela
Patricia Gavela
EDISON NOVOAEDISON NOVOA
EDISON NOVOA
DADaniela Agila
Daniela Agila
This paper proposes a methodology for evaluating and prioritizing photovoltaic distributed generation (PV-DG) projects in unbalanced low- and medium-voltage networks. The analysis shows how the location, installed capacity, and type of DG connection directly influence critical variables such as voltage profile, power losses, harmonic distortion, and voltage unbalance. Based on simulations developed for 24 PV-DG integration scenarios, the proposed methodology supports the selection of single-phase and three-phase DG projects connected to low- and medium-voltage networks. It serves as a tool that integrates technical criteria to support decision-making processes related to the planning and implementation of distributed generation projects.

2 November 2026 in Engineering Proceedings
Verified
Conference Paper
Open access
PDF file
EDISON NOVOAEDISON NOVOA
EDISON NOVOA
JCJaime Cristóbal Cepeda
Jaime Cristóbal Cepeda
SPSebastián Salazar Pérez
Sebastián Salazar Pérez
ESEduardo J. Salazar
Eduardo J. Salazar
GSGabriel Salazar-Yépez
Gabriel Salazar-Yépez
This paper assesses the voltage ride-through (VRT) performance of a 1 MW grid-following photovoltaic (PV) plant connected to the IEEE 13-node unbalanced distribution feeder. Unbalanced RMS simulations in DIgSILENT PowerFactory 2024 SP5A (x64) consider single-phase-to-ground, phase-to-phase, and three-phase faults at the point of common coupling, as well as intentional islanding supported by a 3.5 MVA synchronous diesel generator. Under grid-connected operation, the PV plant remains connected for all simulated faults; the symmetrical three-phase case satisfies the Category-B ARCONEL-001/24 VRT envelope, while the asymmetric cases reveal phase-dependent behavior and temporary healthy-phase overvoltages. During islanding, the synchronous generator establishes the voltage and frequency reference, allowing the GFL PV plant to recover stable operation. The island frequency peaks at 60.929 Hz and settles near 60.664 Hz, both within the 59–61 Hz unlimited-operation band used as a regulatory reference. The results emphasize the importance of unbalanced modeling and grid-forming capability in inverter-rich distribution networks.

7 November 2024 in Engineering Proceedings
Verified
Conference Paper
Open access
PDF file
Juan David RamírezJuan David Ramírez
Juan David Ramírez
DPDarwin Pozo
Darwin Pozo
EDISON NOVOAEDISON NOVOA
EDISON NOVOA
JMJORGE LUIS MEDINA
JORGE LUIS MEDINA
WCWilliam Chamorro
William Chamorro
Alex ValenzuelaAlex Valenzuela
Alex Valenzuela
The High Voltage Laboratory (LABAV) at the Escuela Politécnica Nacional conducts dielectric tests on safety shoes in accordance with the ASTM F2412-18 standard. Additionally, as per the NTE INEN ISO 17025 standard, the laboratory must estimate the uncertainty of its measurements. Despite the scarcity of examples in the existing literature, this work provides a real-world example to assist other laboratories in replicating the uncertainty estimation process. In this article, we systematically present the calculation of leakage current uncertainty in shoes using both the traditional “Guide to the Expression of Uncertainty in Measurement” (GUM) method and the Monte Carlo method (MCM) for validation. The results from both approaches yield a similar uncertainty value of u = 0.0733 mA. Finally, we highlight the advantages that the MCM method offers in this context.

27 July 2023 in Revista Técnica "Energía"
Verified
Journal Article
Open access
PDF file
EDISON NOVOAEDISON NOVOA
EDISON NOVOA
GYGabriel Salazar Yépez
Gabriel Salazar Yépez
EBEliana Buitrón
Eliana Buitrón
SPSebastián Salazar Pérez
Sebastián Salazar Pérez
El artículo presenta una propuesta para la focalización del subsidio tarifa de la dignidad en los usuarios residenciales de las empresas de distribución de energía eléctrica del Ecuador. Para la focalización se utiliza la técnica de agrupación de datos considerando las características técnicas, geográficas y socioeconómicas de los usuarios. El artículo describe el proceso necesario para recopilar, depurar y procesar los datos a fin de que puedan ser utilizados para la focalización del subsidio. Luego, se detalla el proceso necesario para emparejar los datos y consolidarlos en una sola base de datos de usuarios residenciales. En una siguiente fase, se define una ecuación de pobreza que considera, de manera ponderada, las características técnicas y socioeconómicas de los usuarios y que permite calcular su nivel de pobreza individual. Luego, se describe la forma de agrupar a los usuarios según su nivel de pobreza, así como la manera de establecer la mejor cantidad de grupos que se deben generar de entre los usuarios. Finalmente, el artículo presenta una propuesta metodológica general para focalizar el subsidio tarifa de la dignidad en el Ecuador. El presente artículo presenta los resultados de la focalización del subsidio tarifa de la dignidad aplicada a los usuarios residenciales del Distrito Metropolitano de Quito.