We report the laser ablation ignition of premixed methane and oxygen-enriched air mixtures using a tantalum target. The minimum laser pulse energy (MPE) of the ablation ignition was obtained as 2–4 mJ, which was reduced by one order of magnitude compared with that of the direct laser-induced gas breakdown ignition. The ignition time of the ablation ignition was investigated for the first time, to our best knowledge, by measuring the emission signal profiles due to the successfully ignited flames, and an ignition time as short as was obtained. The reduction in MPE will promote the miniaturization and, thus, the practical applications of laser ignition systems.
We report the laser induced spark ignition (LSI) of coaxial methane/oxygen/nitrogen diffusion flames using the 1064 nm output of a Q-switched Nd:YAG laser. The minimum ignition energy (MIE) and ignition time of the LSI has been determined by measuring the emission signals due to the ignited flames. The effects of the gas mixture properties, including the overall equivalence ratio (Ф), oxygen concentration and flow rate, and the ignition positions on the two parameters have been investigated systematically. The variation of the MIE and ignition time with the experimental conditions has been compared with the existing results and discussed with a special concentration on the effects of the local Ф.
Airborne streak tube imaging LiDAR (STIL) consists of several different data-generating subsystems and introduces system errors each time it is installed on an aircraft. These errors change with each installation, which makes the parametric calibration of the LiDAR meaningless. In this study, we propose a high-precision reconstruction method for point clouds that can be used without calibrating the system parameters. In essence, after each remote sensing measurement, a self-checking process is performed with experimental data to replace the fixed system parameters. In this process, the splicing error of the same region measured under different conditions is used as a criterion to optimize the reconstruction parameters via a particle swarm optimization (PSO) algorithm. For a detection distance of 3000 m, the elevation error of the point cloud reconstruction reaches more than 1 m if the placement parameters are not optimized; after optimization, the elevation error can be controlled within 0.3 m.
Owing to the special working systems of streak tube imaging lidar (STIL), the time and space dimensions are coupled together on the streak images. This coupling can cause measurement errors in 3D point clouds and can make measurement results more complicated to calibrate than other kinds of lidars. This paper presents a method to generate a time calibration array and an angle calibration array to separate the offset of the streak into time dimension and space dimension. The time and space information of the signal at any position on the streak image can be indexed through these two arrays. A validation experiment on aircraft was carried out, and the range error of the 3D point cloud was improved from 0.41 m to 0.27 m using the proposed calibration method. Thus, using the proposed calibration method can improve the accuracy of the point cloud produced by STIL.
Time-resolved resonance-enhanced coherent anti-Stokes Raman scattering (CARS) is applied to investigate molecular dynamics in gaseous iodine. 40 fs laser pulses are applied to create and monitor the high vibrational states of iodine at room temperature (corresponding to a vapor pressure as low as about 35 Pa) by femtosecond time-resolved CARS. Depending on the time delay between the probe pulse and the pump/Stokes pulse pairs, the high vibrational states both on the electronically ground states and the excited states can be detected as oscillations in the CARS transient signal. It is proved that the femtosecond time-resolved CARS technique is a promising candidate for investigating the molecular dynamics of a low concentration system and can be applied to environmental and atmospheric monitoring measurements.