Larysa Linetska

Larysa Linetska

Auto-generated profile, based on publicly available information

Larysa Linetska

National Technical University “Kharkiv Polytechnic Institute

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2017 in Computers in Biology and Medicine
Verified
Journal Article
Closed access
ILIgor Linetskiy
Igor Linetskiy
VDVladyslav Demenko
Vladyslav Demenko
LLLarysa Linetska
Larysa Linetska
OYOleg Yefremov
Oleg Yefremov

25 March 2013 in Computer Methods in Biomechanics and Biomedical Engineering
Verified
Journal Article
Closed access
VDVladyslav Demenko
Vladyslav Demenko
ILI. Linetsky
I. Linetsky
VNV. Nesvit
V. Nesvit
LLL. Linetska
L. Linetska
ASA. Shevchenko
A. Shevchenko
Extreme stresses in surrounding bone are among the most important reasons for implant failure. Bone density (quality) is a variable that plays a decisive role in achieving predictable osseointegration and long-term survival of implants. The magnitudes of ultimate occlusal load, which generate ultimate von Mises stress at the critical point of peri-implant area for the spectrum of implants inserted into mandible with four different bone qualities (Lekholm and Zarb classification), were calculated. Geometric models of mandible segment were generated from computed tomography images and analysed with osseointegrated cylindrical implants of various dimensions. Occlusal loads were applied in their natural direction. All materials were assumed to be linearly elastic and isotropic. The investigation suggests that an implant's ultimate occlusal load indicates its load-carrying capacity. As a result, bone loss can be predicted, and viable implants can be selected by comparing the values of their ultimate occlusal load in different clinical conditions.

8 January 2015 in Computer Methods in Biomechanics and Biomedical Engineering
Verified
Journal Article
Closed access
VDVladyslav Demenko
Vladyslav Demenko
ILIgor Linetskiy
Igor Linetskiy
LLLarysa Linetska
Larysa Linetska
VNVitalij Nesvit
Vitalij Nesvit
ASAndrii Shevchenko
Andrii Shevchenko
HWHans-Werner Weisskircher
Hans-Werner Weisskircher
Dental implant failure is mainly the consequence of bone loss at peri-implant area. It usually begins in crestal bone. Due to this gradual loss, implants cannot withstand functional force without bone overload, which promotes complementary loss. As a result, implant lifetime is significantly decreased. To estimate implant success prognosis, taking into account 0.2 mm annual bone loss for successful implantation, ultimate occlusal forces for the range of commercial cylindrical implants were determined and changes of the force value for each implant due to gradual bone loss were studied. For this purpose, finite element method was applied and von Mises stresses in implant-bone interface under 118.2 N functional occlusal load were calculated. Geometrical models of mandible segment, which corresponded to Type II bone (Lekholm & Zarb classification), were generated from computed tomography images. The models were analyzed both for completely and partially osseointegrated implants (bone loss simulation). The ultimate value of occlusal load, which generated 100 MPa von Mises stresses in the critical point of adjacent bone, was calculated for each implant. To estimate longevity of implants, ultimate occlusal loads were correlated with an experimentally measured 275 N occlusal load (Mericske-Stern & Zarb). These findings generally provide prediction of dental implants success.

24 September 2024 in Prosthesis
Verified
Journal Article
Open access
PDF file
Andrii KondratievAndrii Kondratiev
Andrii Kondratiev
VDVladyslav Demenko
Vladyslav Demenko
ILIgor Linetskiy
Igor Linetskiy
HWHans-Werner Weisskircher
Hans-Werner Weisskircher
LLLarysa Linetska
Larysa Linetska
Background/Objectives: Dental implants have emerged as a modern solution for edentulous jaws, showing high success rates. However, the implant’s success often hinges on the patient’s bone quality and quantity, leading to higher failure rates in poor bone sites. To address this issue, short implants have become a viable alternative to traditional approaches like bone sinus lifting. Among these, Bicon® short implants with a plateau design are popular for their increased surface area, offering potential advantages over threaded implants. Despite their promise, the variability in patient-specific bone quality remains a critical factor influencing implant success and bone turnover regulated by bone strains. Excessive strains can lead to bone loss and implant failure according to Frost’s “Mechanostat” theory. To better understand the implant biomechanical environment, numerical simulation (FEA) is invaluable for correlating implant and bone parameters with strain fields in adjacent bone. The goal was to establish key relationships between short implant geometry, bone quality and quantity, and strain levels in the adjacent bone of patient-dependent elasticity to mitigate the risk of implant failure by avoiding pathological strains. Methods: Nine Bicon Integra-CP™ implants were chosen. Using CT scans, three-dimensional models of the posterior maxilla were created in Solidworks 2022 software to represent the most challenging scenario with minimal available bone, and the implant models were positioned in the jaw with the implant apex supported by the sinus cortical bone. Outer dimensions of the maxilla segment models were determined based on a prior convergence test. Implants and abutments were considered as a single unit made of titanium alloy. The bone segments simulated types III/IV bone by different cancellous bone elasticities and by variable cortical bone elasticity moduli selected based on an experimental data range. Both implants and bone were treated as linearly elastic and isotropic materials. Boundary conditions were restraining the disto-mesial and cranial surfaces of the bone segments. The bone–implant assemblies were subjected to oblique loads, and the bone’s first principal strain fields were analyzed. Maximum strain values were compared with the “minimum effective strain pathological” threshold of 3000 microstrain to assess the implant prognosis. Results: Physiological strains ranging from 490 to 3000 microstrain were observed in the crestal cortical bone, with no excessive strains detected at the implant neck area across different implant dimensions and cortical bone elasticity. In cancellous bone, maximum strains were observed at the first fin tip and were influenced by the implant diameter and length, as well as bone quality and cortical bone elasticity. In the spectrum of modeled bone elasticity and implant dimensions, increasing implant diameter from 4.5 to 6.0 mm resulted in a reduction in maximum strains by 34% to 52%, depending on bone type and cortical bone elasticity. Similarly, increasing implant length from 5.0 to 8.0 mm led to a reduction in maximum strains by 15% to 37%. Additionally, a two-fold reduction in cancellous bone elasticity modulus (type IV vs. III) corresponded to an increase in maximum strains by 16% to 59%. Also, maximum strains increased by 86% to 129% due to a decrease in patient-dependent cortical bone elasticity from the softest to the most rigid bone. Conclusions: The findings have practical implications for dental practitioners planning short finned implants in the posterior maxilla. In cases where the quality of cortical bone is uncertain and bone height is insufficient, wider 6.0 mm diameter implants should be preferred to mitigate the risk of pathological strains. Further investigations of cortical bone architecture and elasticity in the posterior maxilla are recommended to develop comprehensive clinical recommendations considering bone volume and quality limitations. Such research can potentially enable the placement of narrower implants in cases of insufficient bone.

8 June 2023 in Bulletin of the National Technical University «KhPI» Series: New solutions in modern technologies
Verified
Journal Article
Open access
PDF file
AKAndrii Kipenskyi
Andrii Kipenskyi
VKViacheslav Kulichenko
Viacheslav Kulichenko
YVYurii Voitovych
Yurii Voitovych
LLLarysa Linetska
Larysa Linetska
The industrial production of powerful light-emitting diodes has led to the appearance of devices for therapeutic purposes, where such diodes are used as sources of electromagnetic radiation in the optical range. The development and production of such devices was established in the city of Kharkiv with the participation of scientists and specialists of Kharkiv National University named after V.M. Karazin and National Technical University "Kharkiv Polytechnic Institute". Methods of using devices and hardware complexes in medical practice were created at the Kharkiv Medical Academy of Postgraduate Education. The article analyzes the main principles of building modular hardware complexes for LED therapy, defines structures and options for connecting modules. As a result of the work performed, it was established that the modular implementation of hardware complexes for LED therapy has five main options, which differ in the number and types of emitters connected to the control unit, in the connection scheme of photon emitters, and in their functionality. It was also noted that the modular principle of building hardware complexes for LED therapy makes it quite easy to carry out their modernization and form the necessary configuration of the irradiating system, that is, to significantly expand the functional capabilities of the complex for carrying out phototherapy treatment procedures with the greatest efficiency. The expediency of using microprocessor technology for the implementation of the information part of the control unit of the complex is shown. This makes it possible to ensure the operation of photon emitters in continuous, pulsed and scanning modes, as well as separate operation of the emitters of the irradiation system of the complex and irradiation of the patient in biosynchronization mode.

7 October 2024
Verified
Conference Paper
Closed access
Andrii KondratievAndrii Kondratiev
Andrii Kondratiev
MSMichael Sutcliffe
Michael Sutcliffe
VDVladyslav Demenko
Vladyslav Demenko
ILIgor Linetskiy
Igor Linetskiy
OYOleg Yefremov
Oleg Yefremov
LLLarysa Linetska
Larysa Linetska
At present, the topic of traumatism of the maxillofacial region is topical and requires the search for contemporary biomechanical solutions. It is known that the problem of mandibular traumatism ranks first among all injuries of the maxillofacial region. Treatment of mechanically failured human mandible was considered as the example of its body fracture in accordance with European classification of maxillofacial trauma. This type of injury was chosen because of its widespread, statistically supported incidence. The treatment method was based on the use of osteosynthesis systems, widely used in the healthcare systems of Western European countries. The purpose of the study was in biomechanical support of existing clinical protocols for the osteosynthesis system elements application to ensure positive treatment prospects. Finite element analysis of acting deformations and displacements in the adjacent bone tissues was carried out for the case of reconstruction of the lower jaw damaged by an oblique fracture in its middle part (body) using two mini-plates in accordance with current clinical protocol. In our case, fracture was fixated with two 1.25 mm in thickness titanium mini-plates. Two types of mini-plates with lengths of 27 mm (long) and 20.5 mm (short) between the axes of the outer holes were analyzed. The results was revealed that osteosynthesis systems technology provides the conditions for the fixed mandible ridges healing under gentle functional loading due to safe micromotions which do not exceed 150 micrometer threshold of safe displacements (0.15 mm for long mini-plate 27×2.5×1.25 mm and 0.13 mm for short mini-plate 20.5×3.5×1.25mm). Also, the largest sliding distance in the fracture section are 0.11 mm for long mini-plate 27×2.5×1.25 mm and 0.06 mm for short mini-plate 27×2.5×1.25 mm. From this viewpoint, short mini-plate is recommended as preferable. However, care should be taken in transferring the results to the clinical situation. First of all, the wider range of possible bone fractures and their actual shapes with possible deviations from a flat contour should be taken into account. Also, more adequate simulation of the crack ridges interface should be provided to answer the question on micromotion data accuracy influencing the crack fixation and the success of the bone healing.