Theophilos Maltezopoulos

Dr. Theophilos Maltezopoulos


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 June 2019 in Journal of Synchrotron Radiation
Verified
Journal Article
Closed access
PDF file
TMTheophilos Maltezopoulos
Theophilos Maltezopoulos
FDFlorian Dietrich
Florian Dietrich
WFWolfgang Freund
Wolfgang Freund
UJUlf Fini Jastrow
Ulf Fini Jastrow
AKAndreas Koch
Andreas Koch
JGJan Gruenert
Jan Gruenert

15 April 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
SSSvitozar Serkez
Svitozar Serkez
WDWinfried Decking
Winfried Decking
LFLars Froehlich
Lars Froehlich
NGNatalia Gerasimova
Natalia Gerasimova
JGJan Gruenert
Jan Gruenert
GGGianluca Geloni
Gianluca Geloni
X-ray pump/X-ray probe applications are made possible at X-ray Free Electron Laser (XFEL) facilities by generating two X-ray pulses with different wavelengths and controllable temporal delay. In order to enable this capability at the European XFEL, an upgrade project to equip the soft X-ray SASE3 beamline with a magnetic chicane is underway. In the present paper we describe the status of the project, its scientific focus and expected performance, including start-to-end simulations of the photon beam transport up to the sample, as well as recent experimental results demonstrating two-color lasing at photon energies of 805 eV + 835 eV and 910 eV + 950 eV. Additionally, we discuss methods to analyze the spectral properties and the intensity of the generated radiation to provide on-line diagnostics for future user experiments.
1

19 August 2019 in Journal of Synchrotron Radiation
Verified
Journal Article
Closed access
PDF file
AKAndreas Koch
Andreas Koch
JRJohannes Risch
Johannes Risch
WFWolfgang Freund
Wolfgang Freund
TMTheophilos Maltezopoulos
Theophilos Maltezopoulos
MPMarc Planas
Marc Planas
JGJan Gruenert
Jan Gruenert

10 May 2023 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
TBThomas Marcus Baumann
Thomas Marcus Baumann
RBRebecca Boll
Rebecca Boll
AFAlberto De Fanis
Alberto De Fanis
PGPatrik Grychtol
Patrik Grychtol
MIMarkus Ilchen
Markus Ilchen
MMMichael Meyer
Michael Meyer
Transmission measurements of the soft X-ray beamline to the Small Quantum Systems (SQS) scientific instrument at the SASE3 undulator of European XFEL are presented. Measurements are reported for a wide range of photon energies (650 eV to 2400 eV), using X-ray gas monitors as well as a bolometric radiometer. The results are in good agreement with simulations for the beam transport and show a transmission of up to 80% over the whole photon energy range. The contribution of second- and third-harmonic radiation of the soft X-ray undulator is determined at selected photon energies by performing transmission measurements using a gas absorber to provide variable attenuation of the incoming photon flux. A comparison of the results with semi-analytic calculations for the generation of free-electron laser pulses in the SASE3 undulator reveals an influence of apertures along the beam transport on the exact harmonic content to be accounted for at the experiment. The second-harmonic content is measured to be in the range of 0.1% to 0.3%, while the third-harmonic contributed a few percent to the SASE3 emission. For experiments at the SQS instrument, these numbers can be reduced through specific selections of the mirror reflection angles.

27 January 2023 in Photonics
Verified
Journal Article
Open access
PDF file
ATAndrei Trebushinin
Andrei Trebushinin
GGGianluca Geloni
Gianluca Geloni
SSSvitozar Serkez
Svitozar Serkez
GMGiuseppe Mercurio
Giuseppe Mercurio
NGNatalia Gerasimova
Natalia Gerasimova
ESEvgeny Schneidmiller
Evgeny Schneidmiller
We report on observations of single spike spectra (3–13% of events) upon employing a previously proposed method for single spike generation via harmonic conversion. The method was tested at the soft X-ray SASE3 undulator of the European XFEL. The first part of the undulator allows one to amplify bunching at the fundamental as well as the higher harmonics. The downstream undulator is tuned to a harmonic, the fourth in our case, to amplify pulses with a shorter duration. We estimate the generated pulse duration within such a subset of short pulses at a level of 650 as. Considering the demonstrated probability of single spike events, this method is attractive for high repetition-rate free electron lasers.

5 June 2024 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
TMTheophilos Maltezopoulos
Theophilos Maltezopoulos
FBFrank Brinker
Frank Brinker
FDFlorian Dietrich
Florian Dietrich
WFWolfgang Freund
Wolfgang Freund
JGJan Gruenert
Jan Gruenert
Thomas TschentscherThomas Tschentscher
Thomas Tschentscher
X-ray gas monitors (XGMs) are operated at the European XFEL for non-invasive single-shot pulse energy measurements and average beam-position monitoring. The underlying measurement principle is the photo-ionization of rare gas atoms at low gas pressures and the detection of the photo-ions and photo-electrons created. These are essential for tuning and sustaining self-amplified spontaneous emission (SASE) operation, machine radiation safety, and sorting single-shot experimental data according to pulse energy. In this paper, the first results from XGM operation at photon energies up to 30 keV are presented, which are far beyond the original specification of this device. Here, the Huge Aperture MultiPlier (HAMP) is used for single-shot pulse energy measurements since the standard X-ray gas monitor detectors (XGMDs) do not provide a sufficient signal-to-noise ratio, even at the highest operating gas pressures. A single-shot correlation coefficient of 0.98 is measured between consecutive XGMs operated with HAMP, which is as good as measuring with the standard XGMD detectors. An intra-train non-linearity of the HAMP signal is discovered, and operation parameters to mitigate this effect are studied. The upper repetition rate limit of HAMP operation at 2.25 MHz is also determined. Finally, the possibilities and limits for future XGM operation at photon energies up to 50 keV are discussed.