Bacteria Acinetobacter baumannii is a persistent issue in hospital-acquired infections due to its fast and potent development of multi-drug resistance. To address this urgent challenge, a novel biomaterial using silver (Ag+) ions within the hydroxyapatite (HAp) lattice has been developed to prevent infections in orthopedic surgery and bone regeneration applications without relying on antibiotics. The aim of the study was to examine the antibacterial activity of mono-substituted HAp with Ag+ ions and a mixture of mono-substituted HAps with Sr2+, Zn2+, Mg2+, SeO32- and Ag+ ions against the A. baumannii. The samples were prepared in the form of powder and disc and analyzed by disc diffusion, broth microdilution method, and scanning electron microscopy. The results from the disc-diffusion method have shown a strong antibacterial efficacy of the Ag-substituted and mixture of mono-substituted HAps (Sr, Zn, Se, Mg, Ag) toward several clinical isolates. The Minimal Inhibitory Concentrations for the powdered HAp samples ranged from 32 to 42 mg/L (Ag+ substituted) and 83-167 mg/L (mixture of mono-substituted), while the Minimal Bactericidal Concentrations after 24 h of contact ranged from 62.5 (Ag+) to 187.5-292 mg/L (ion mixture). The lower substitution level of Ag+ ions in a mixture of mono-substituted HAps was the cause of lower antibacterial effects measured in suspension. However, the inhibition zones and bacterial adhesion on the biomaterial surface were comparable. Overall, the clinical isolates of A. baumannii were effectively inhibited by substituted HAp samples, probably in the same amount as by other commercially available silver-doped materials, and such materials may provide a promising alternative or supplementation to antibiotic treatment in the prevention of infections associated with bone regeneration. The antibacterial activity of prepared samples toward A. baumannii was time-dependent and should be considered in potential applications.
This study aimed to determine the effects of three different varnish materials (containing casein phosphopeptide-amorphous calcium phosphate, nano-hydroxyapatite, and fluoride) on enamel. Thirty-three extracted human third molars were used for specimen preparation. These were demineralized using phosphoric acid. Three experimental groups (n = 11) were treated with 3M™ Clinpro™ White Varnish, MI Varnish®, and Megasonex® toothpaste, respectively, every twenty-four hours for fourteen days. Analysis of the microhardness of the specimens’ enamel surfaces was carried out via the Vickers method, and by scanning electron microscopy/energy dispersive X-ray spectroscopy (SEM/EDS). Analysis was performed at three stages: at baseline value, after demineralization, and after the period of remineralization. Data were subjected to Scheffe’s post hoc test. The mean microhardness values (HV0.1) obtained for the group of samples treated with MI Varnish® were higher compared with the other two groups (p = 0.001 for both comparisons), while the first and third groups did not differ significantly from each other (p = 0.97). SEM analysis showed uneven patterns and porosities on all samples tested. EDS results showed an increase in the mineral content of the examined samples, with the highest mineral content observed in the MI Varnish® group. It can be concluded that MI Varnish® use has a better remineralization effect on enamel than the other two materials.
Laser-powder bed fusion (LPBF) is one of the preferred techniques for producing Co-Cr metal structures for dental prosthodontic appliances. However, there is generally insufficient information about material properties related to the production process and parameters. This study was conducted on samples produced from three different commercially available Co-Cr dental alloys produced on three different LPBF machines. Identically prepared samples were used for tensile, three-point bending, and toughness tests. Light microscopy (LM), scanning electron microscopy (SEM), and electron backscatter diffraction (EBSD) analyses of microstructure were performed after testing. Differences were observed in microstructures, which reflected statistically significant differences in mechanical properties (one-way analysis of variance (ANOVA) and Scheffé post hoc test (α = 0.05)). The material produced on the 3D Systems DMP Dental 100 had 24 times greater elongation ε than the material produced on the Sysma MySint 100 device and the EOS M100 machine. On the other hand, the material produced on the EOS M100 had significantly higher hardness (HV0.2) than the other two produced materials. However, the microstructure of the Sysma specimens with its morphology deviates considerably from the studied group. LPBF-prepared Co-Cr dental alloys demonstrated significant differences in their microstructures and, consequently, mechanical properties.
This paper investigates the casting defects of a stainless steel pump impeller manufactured through the sand casting process. The material characterization of austenitic steel AISI 316L was initially carried out, which examined the chemical composition of the casting and its microstructure. The next step was to determine the cause of the casting defects using numerical simulations. The numerical simulations were performed using ProCAST software (Version 18.0). Initial results of the filling and solidification simulations were conducted using the parameters employed in the actual casting process, revealing casting defects in corresponding locations. The casting process was subsequently modified to achieve improved results. This involved reconstructing the gating system, redesigning the riser, and incorporating a cylindrical chiller. The results show that the modified casting process significantly reduces the occurrence of defects in the final product. The study provides useful insights into the analysis and modification of the casting process for stainless steel pump impellers produced through sand casting. The results can help improve the quality of such products and reduce production costs associated with casting defects.
Silanized glass fibers are popular reinforcements of acrylic denture base materials. To increase the number of surface hydroxyl groups and to improve interfacial adhesion between the matrix and reinforcements, acid or base treatments of glass fibers are commonly performed before the silanization. However, limited data are available on the effect of these treatments on the mechanical properties of acrylic matrix composite materials used for denture base applications. In this work, before the silanization of a woven glass fiber fabric (GF) with 3-(trimethoxysilyl) propyl methacrylate, activation pretreatments using HCl and NH4OH aqueous solutions have been performed. To characterize the glass surface, FTIR spectroscopy was used. Specimens of cured acrylic denture base resin and composites were divided into five groups: (1) cured acrylic denture base resin-control group; (2) composite with non-silanized GF; (3) composite with silanized GF; (4) composite with NH4OH activated and silanized GF; (5) composite with HCl activated and silanized GF. The flexural and impact properties of specimens were evaluated by means of three-point-bending tests and Charpy impact testing, respectively. The residual reactivity of the samples was analyzed using differential scanning calorimetry. The results of mechanical testing showed that acid and base pretreatments of the glass fabric had a positive effect on the flexural modulus of prepared composites but a negative effect on their impact strength. Possible interfacial adhesion mechanisms and the diffusion control of isothermal cure reactions due to vitrification have been discussed.
1 December 2018 in Tehnicki vjesnik - Technical Gazette
The wear of induction cladded coating during motion was investigated through the abrasive mass at a speed of 1.0 to 3.0 m/s and the impact angle of abrasive particles with a worn surface of 0° to 90°. Cladding was performed by using...