Ivan Šalinović

Dr. Ivan Šalinović

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 October 2021 in Materials
Verified
Journal Article
Open access
PDF file
IŠIvan Šalinović
Ivan Šalinović
ZSZdravko Schauperl
Zdravko Schauperl
MMMarijan Marcius
Marijan Marcius
Ivana MileticIvana Miletic
Ivana Miletic
This study aimed to determine the effects of three different varnish materials (containing casein phosphopeptide-amorphous calcium phosphate, nano-hydroxyapatite, and fluoride) on enamel. Thirty-three extracted human third molars were used for specimen preparation. These were demineralized using phosphoric acid. Three experimental groups (n = 11) were treated with 3M™ Clinpro™ White Varnish, MI Varnish®, and Megasonex® toothpaste, respectively, every twenty-four hours for fourteen days. Analysis of the microhardness of the specimens’ enamel surfaces was carried out via the Vickers method, and by scanning electron microscopy/energy dispersive X-ray spectroscopy (SEM/EDS). Analysis was performed at three stages: at baseline value, after demineralization, and after the period of remineralization. Data were subjected to Scheffe’s post hoc test. The mean microhardness values (HV0.1) obtained for the group of samples treated with MI Varnish® were higher compared with the other two groups (p = 0.001 for both comparisons), while the first and third groups did not differ significantly from each other (p = 0.97). SEM analysis showed uneven patterns and porosities on all samples tested. EDS results showed an increase in the mineral content of the examined samples, with the highest mineral content observed in the MI Varnish® group. It can be concluded that MI Varnish® use has a better remineralization effect on enamel than the other two materials.

15 September 2023 in Acta Stomatologica Croatica
Verified
Journal Article
Open access
LBLLubitza Slaviza Banic
LLubitza Slaviza Banic
NVNikolina Nika Veček
Nikolina Nika Veček
IŠIvan Šalinović
Ivan Šalinović
Ivana MileticIvana Miletic
Ivana Miletic
EKEva Klarić
Eva Klarić
SKSilvana Jukić Krmek
Silvana Jukić Krmek
To compare short-term release of fluoride ions from ion-releasing dental restorative materials. Seven experimental groups were prepared using the following six different materials: alkasite (Cention Forte), resin-modified glass ionomer cement (Fuji II LC), bioactive composite (ACTIVA BioACTIVE-RESTORATIVE), fluoride-containing nano-hybrid composite (Luminos UN), coat-free glass hybrid (EQUIA Forte HT), coat-applied glass hybrid (EQUIA Forte HT), and glass ionomer cement (Fuji IX). A total of 40 samples for each group (n=40) were prepared in Teflon molds (8 mm x 2 mm) and placed in polyethylene vials with 5 ml of deionized water. Fluoride release was measured after 6, 24, 48 hours, and for 5 weeks using an ion-selective electrode. The results were expressed in mg/l and the data were statistically analyzed using ANOVA. Significant differences in fluoride release were observed within the first 6 hours (ANOVA p<0.001). EQUIA Forte HT had the highest release, while the other materials showed no significant differences. After 24 hours, EQUIA Forte HT (p<0.001) and Luminos UN (p<0.05) exhibited significantly higher releases, compared to other tested materials. EQUIA Forte HT maintained the highest release at 48 hours (p<0.001), followed by Cention Forte (p<0.05) and Luminos UN (p<0.05). All material pairs showed significant differences in fluoride release at 5 weeks (p<0.001). Coat-free EQUIA Forte HT had the overall highest fluoride release, while Cention Forte demonstrated the greatest increase over time. ACTIVA BioACTIVE-RESTORATIVE exhibited the lowest fluoride release in this study.

25 January 2022 in Materials
Verified
Journal Article
Open access
PDF file
MČMaja Zečević Čulina
Maja Zečević Čulina
VRValentina Brzović Rajić
Valentina Brzović Rajić
IŠIvan Šalinović
Ivan Šalinović
EKEva Klarić
Eva Klarić
LMLuka Marković
Luka Marković
AIAna Ivanišević
Ana Ivanišević
The purpose of this in vitro study was to evaluate erosive wear and change in color of high-viscosity glass ionomer cements after pH cycling in two erosive media. There were 3 experimental groups with 22 samples each, (I) EQUIA Forte HT without coat, (II) Fuji IX and (III) Ketac Universal Aplicap. Each group was randomly divided into three subgroups (n = 6–8) further exposed to different environments, (1) distilled water, (2) green tea (pH 3.78) and (3) Aceto balsamico vinegar (pH 3.0). Mass and L* a* b* values were recorded before and after pH cycling. The samples in subgroups 2 and 3 were exposed to the acidic media two times a day for 10 min, over a period of 14 days. The differences among materials and erosive effects of the three media were tested using three-way analyses of variance with post hoc LSD test at the significance level p < 0.05. The effect of pH cycling in Aceto balsamico and green tea was degrading for all three materials. pH cycling in Aceto balsamico caused significantly higher erosive wear than pH cycling in Fuzetea and storage in distilled water, in all materials (p < 0.05). pH cycling in both acidic media and in the control group resulted in a significant change in L* a* and b* (p < 0.05). The L* value decreased significantly and the a* and b* values increased significantly (p < 0.05).

23 February 2024 in Polymers
Verified
Journal Article
Open access
PDF file
AIAnja Ivica
Anja Ivica
IŠIvan Šalinović
Ivan Šalinović
SKSilvana Jukić Krmek
Silvana Jukić Krmek
Sufyan GaroushiSufyan Garoushi
Sufyan Garoushi
Lippo LassilaLippo Lassila
Lippo Lassila
Ivana MileticIvana Miletic
Ivana Miletic
The aim of this study was to compare the mechanical properties and ion release from a commercially available resin-modified glass ionomer cement to a formulation reinforced by the addition of short glass fibres at various percentages. Methods: Three experimental groups were prepared by adding a mass ratio of 10%, 15% and 20% of short glass fibres to the powder portion of the cement from a capsule (GC Fuji II LC), while the control group contained no fibres. Microhardness (n = 12), fracture toughness, and flexural, compressive and diametral tensile strength (n = 8) were evaluated. To study ion release, readings were obtained utilising fluoro-selective and calcium-selective electrodes after 24 h, 7 days and 30 days (n = 12). The spatial distribution of fibres within the material was evaluated through scanning electron microscopy. The data were analysed using one-way ANOVA with a Bonferroni adjustment. Results: The findings suggest that elevating fibre weight ratios to 20 wt% results in improved mechanical properties (p < 0.05) in microhardness, flexural strength, diametral tensile strength and fracture toughness. In terms of ion release, a statistically significant difference (p < 0.001) was observed between the groups at the conclusion of 24 h and 7 days, when the fluoride release was much higher in the control group. However, after 30 days, no significant distinction among the groups was identified (p > 0.05). Regarding calcium release, no statistically significant differences were observed among the groups at any of the evaluated time points (p > 0.05). SEM showed the fibres were homogeneously incorporated into the cement in all experimental groups. Conclusions: Resin-modified glass ionomer enhanced with short glass fibres at a weight loading of 20% showcased the most favourable mechanical properties while concurrently maintaining the ability to release fluoride and calcium after a 30-day period.

21 November 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MBMaja Bilić-Prcić
Maja Bilić-Prcić
IŠIvan Šalinović
Ivan Šalinović
SGSevil Gurgan
Sevil Gurgan
UKUzay Koc-Vural
Uzay Koc-Vural
SKSilvana Jukić Krmek
Silvana Jukić Krmek
Ivana MileticIvana Miletic
Ivana Miletic
Background: The aim of this study was to evaluate the effects of incorporation of hydroxyapatite (HA) derived from cuttlefish bone on the microhardness, surface roughness (SR), and fluoride release (FR) of conventional cure, and resin-modified glass-ionomer cement. Methods: There were four groups for each tested material; experimental glass-ionomer were made by addition and of 2, 5, and 10 wt % HA respectively to conventional glass-ionomers Fuji II LC and Fuji IX GP Extra. One group was prepared without the addition of HA particles. For SR and microhardness measurements sectional Teflon molds (5 mm in diameter and 2 mm deep) were used to prepare 10 samples per group (n = 80). The samples were stored in distilled water at 37 °C for 7 days prior to testing. The SR was measured using a contact type profilometer and the microhardness was determined using a Vickers micro-hardness tester at a load of 980 g for 15 s. For FR measurements, there were six samples per group (n = 48), prepared in Teflon molds (8 mm in diameter and 2 mm deep). The FR was measured with an ionoselective electrode in triplicates after 24 h, 7 days, and 45 days. Statistical analysis was performed using one-way ANOVA with Tukey post-hoc test. Results and Conclusion: Microhardness values obtained for Fuji II modified with 10 wt % HA were significantly higher compared to the other two groups tested. Comparison of materials with respect to SR showed significant difference between them (p < 0.0001) with Fuji II and Fuji IX modified with HA having higher SR values. Regarding FR, Fuji IX showed statistically significant higher results than Fuji II, independently of HA modification, and groups modified with 2 and 5 wt % HA showed significantly increased fluoride release in all three time points.

24 November 2023 in Materials
Verified
Journal Article
Open access
PDF file
IŠIvan Šalinović
Ivan Šalinović
Falk SchwendickeFalk Schwendicke
Falk Schwendicke
HAHaitham Askar
Haitham Askar
JYJamila Yassine
Jamila Yassine
Ivana MileticIvana Miletic
Ivana Miletic
The aim of this study was to compare the potential of standard ion-releasing materials to repair demineralized lesions with recently introduced alkasite and glass hybrid materials. Glass ionomer (GC Fuji TRIAGE), two glass hybrids (EQUIA Forte HT, Riva SC), calcium silicate cement (Biodentine) and an alkasite (Cention Forte) were tested. A total of 72 human third molars were used for sample preparation; on the dentine surface, a class-I cavity was prepared, and one half was covered with nail varnish. The teeth were subjected to a demineralization protocol, filled with the examined materials, and cut in half. The evaluation included a dentine microhardness assessment (n = 10) and SEM/EDS analysis (n = 2). The results were analyzed using SPSS 22.0 statistical software and compared using an analysis of variance and Scheffe post-hoc test. The statistical significance level was set to 0.05. Mean microhardness values (HV0.1) after 14 and 28 days were, respectively: EQUIA Forte HT (26.7 ± 1.45 and 37.74 ± 1.56), Riva Self Cure (19.66 ± 1.02 and 29.58 ± 1.18), Cention Forte (19.01 ± 1.24 and 27.93 ± 1.33), Biodentine (23.35 ± 1.23 and 29.92 ± 1.02), GC Fuji TRIAGE (25.94 ± 1.35 and 33.87 ± 5.57) and control group (15.57 ± 0.68 and 15.64 ± 0.82). The results were significantly different between most groups (p < 0.001). SEM/EDS revealed varying patterns, material deposits and distinct elemental variations. To conclude, all materials increased microhardness and affected the dentine surface appearance and chemical composition; EQUIA Forte HT demonstrated the most pronounced effects.