Marc-André Dugas

Marc-André Dugas

Auto-generated profile, based on publicly available information

Marc-André Dugas

Pediatrics Department, Faculty of Medicine, Centre Mre-Enfant Soleil du CHU de Qubec, Universit Laval, Qubec City, QC, Canada

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 May 2020 in IEEE Sensors Journal
Verified
Journal Article
Closed access
MRMourad ROUDJANE
Mourad ROUDJANE
SBSimon Bellemare-Rousseau
Simon Bellemare-Rousseau
EDEtienne Drouin
Etienne Drouin
BBBenjamin Belanger-Huot
Benjamin Belanger-Huot
MDMarc-Andre Dugas
Marc-Andre Dugas
YMYounes Messaddeq
Younes Messaddeq
In this paper, we present the design and the validation of a new smart textile developed for real time monitoring of human breath. The smart textile is a wearable stretching T-shirt featuring an array of six contactless and non-invasive sensors placed on human’s thoraco-abdominal walls. The wireless sensors communicate quasi-simultaneously the data to a detection base station through Bluetooth protocol. The sensor is composed of a spiral shaped multi-material fiber antenna with a central frequency at 2.4 GHz connected to a compact Bluetooth transmitter. The sensors are integrated on the stretchable T-shirt without compromising the user’s comfort. The sensing mechanism of the system is based on the shift of the central frequency of the spiral fiber antenna induced by the deformation of the thorax and the abdomen during the breath. As a consequence, the breathing pattern is obtained through the received signal strength indicator recorded by a portable detection base station. With the sensor array integrated into a T-shirt, we demonstrate the feasibility assessment for monitoring breathing of seven volunteers in seating and standing positions. Using an array of sensors strategically placed on the T-shirt provides a more reliable approach to detect interpretable breathing patterns by sensing the movement of the abdomen and the thorax at the same time. Using a commercial spirometer as a standard reference, we assessed the validity of breathing parameters (ie; expiration and inspiration times, breathing period, and breathing rate) measured with the T-shirt. Based on Bland-Altman statistical analysis, a good agreement between textile-based sensors and the standard reference was obtained. We were able to show that the smart T-shirt could detect breathing patterns and pauses in breathing, which could be very useful to monitor sleep apnea and clinical monitoring of patients.

28 December 2021 in IEEE Sensors Journal
Verified
Journal Article
Closed access
HAHajer Abed
Hajer Abed
SBSimon Bellemare-Rousseau
Simon Bellemare-Rousseau
BBBenjamin Belanger-Huot
Benjamin Belanger-Huot
MAMehran Ahadi
Mehran Ahadi
EDEtienne Drouin
Etienne Drouin
YMYounes Messaddeq
Younes Messaddeq
A new wearable smart T-Shirt design for breathing rate monitoring using Received Signal Strength Indicator (RSSI) is proposed. This new design features three principal functions: a wireless sensor to monitor the breathing rate, a wireless power transfer system, and a user interface to analyze the collected breathing data. First, the breathing curves obtained from a breathing sensor incorporated in a smart T-shirt were presented. Then, the data analysis methods are applied for extracting the important parameters for medical diagnosis. To observe multiple breathing profiles, additional results are presented for different tests on male and female subjects using another design of a smart T-shirt system consisting of an array of six sensors.

28 October 2024 in IEEE Sensors Journal
Verified
Journal Article
Closed access
MAMehran Ahadi
Mehran Ahadi
AMAmine Miled
Amine Miled
MDMarc-André Dugas
Marc-André Dugas
YMYounès Messaddeq
Younès Messaddeq
The Single Antenna Bio-Sensing (SABioS) method is investigated for non-invasive respiratory and cardiac activity monitoring. Using an antenna sensor installed over the chest of a subject, the vital signs can be captured by analyzing changes in the antenna’s reflection coefficient due to two conributors, being the variations in the dielectric composition of the body and the structural deformations of the antenna due to thoracic expansion during the respiratory cycle. The operation principle of this method is elaborated and validated through simulations, and its agreement with a medical-grade reference device is studied via a preliminary experimental setup involving 14 volunteers. The results were analyzed using Bland-Altman analysis, linear regression, and various error metrics, and the maximum calculated mean absolute errors were 0.06 bpm for breathing rate and 0.14 seconds for inspiration/expiration time, demonstrating a strong agreement with the medical reference device. The paper also briefly explores the potential of SABioS in cardiac monitoring and detecting breathing pauses, as well as its versatility in operating with different antenna types. The SABioS method provides a non-invasive, comfortable, and accurate solution for continuous vital sign monitoring without any dependency to external devices.

18 February 2026 in IEEE Transactions on Circuits and Systems I: Regular Papers
Verified
Journal Article
Closed access
MAMehran Ahadi
Mehran Ahadi
AMAmine Miled
Amine Miled
MDMarc-André Dugas
Marc-André Dugas
YMYounès Messaddeq
Younès Messaddeq
Accurate respiratory monitoring is essential in critical care settings where abnormal breathing can indicate rapid deterioration and require immediate intervention. Existing non-invasive approaches face trade-offs in comfort, reliability, and portability, limiting their clinical applicability. Single Antenna Bio-Sensing (SABioS) offers an alternative by capturing local dielectric variations with a single wearable antenna, enabling comfortable, non-invasive monitoring of respiratory and cardiac activity. This work presents an implementation of SABioS on a compact custom PCB operating at 915 MHz in combination with a flexible sinusoidal dipole antenna sensor and a dedicated acquisition software, demonstrating the feasibility of portable, low-power, continuous monitoring. The system was evaluated against synchronized medical-grade reference devices, providing the first validation of SABioS for accurate cardiac activity detection in addition to respiration, with respiratory rate agreement of MoD ± LoA = $0.005~\pm ~0.217$ bpm and heart rate agreement of MoD ± LoA = $0.0096~\pm ~0.322$ bpm. Additional experiments confirmed stable operation of the system in long-term monitoring and robust performance across wearing configurations and body positions, including recumbent scenarios for sleep monitoring with up to 13.7 dB SNR improvement. Compared to the earlier proof-of-concept setups of SABioS, the integrated system achieves considerably higher signal-to-noise ratio and measurement accuracy, with up to +24.2 dB SNR improvement, underscoring its potential for continuous vital signs monitoring in practical healthcare applications.

27 June 2025 in Journal of Pediatric Rehabilitation Medicine
Verified
Journal Article
Open access
VAVirginie Aspirot-Buron
Virginie Aspirot-Buron
Charles BatchoCharles Batcho
Charles Batcho
MBMichèle Bisson
Michèle Bisson
BMBruno Michon
Bruno Michon
MDMarc-André Dugas
Marc-André Dugas
PCPhilippe Corbeil
Philippe Corbeil
Purpose: Limited data are available on the cardiorespiratory and muscle fitness of children with acute lymphoblastic leukemia (ALL) during chemotherapy. This pilot study evaluated the safety of testing the cardiorespiratory and muscle fitness of two children with ALL at different risk levels in early chem treatment. Methods: Two girls with low- and high-risk B-cell ALL (DFCI-16-001) took part in two test sessions: T1 (induction, consolidation 1A/C) and T2 (consolidation 2). Each testing session included a maximal oxygen uptake ( V ˙ O 2 max) exercise test, muscular strength tests, physical activity and quality of life questionnaires, and a semi-structured interview. The parents agreed to these assessments at the start of chemotherapy treatment. Results: The participants experienced no significant adverse effects from undertaking the cardiorespiratory and muscular tests, and there was no impact on their chemotherapy treatment schedule. At their post-test interview, both participants reported that thigh pain and fatigue were the most difficult part of the V ˙ O 2 max exercise test. Regarding physical performance outcomes, both participants exhibited low scores compared to their gender, weight- and age-predicted V ˙ O 2 max and on most strength test values. Conclusion: The physical tests were safely and successfully conducted with these two participants during early chemotherapy.