Qiang Cao

Dr. Qiang Cao


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 December 2023 in Biomimetics
Verified
Journal Article
Open access
PDF file
GLGuoyu Li
Guoyu Li
Rui ZhangRui Zhang
Rui Zhang
YLYexuan Luo
Yexuan Luo
YLYue Liu
Yue Liu
QCQiang Cao
Qiang Cao
Jiafeng SongJiafeng Song
Jiafeng Song
The attachment performances of mechanical feet are significant in improving the trafficability and mobility of robots on the extreme ground. In the future, frozen-ground robots can be used to replace human soldiers in scouting and deep space exploration. In this study, the influence factors on the attachment function of the bionic feet were analyzed. Soft frozen soil and tight frozen soil close to natural frozen soil were prepared, and the friction between ungula and frozen soil ground was simulated together with the plantar pressures of reindeer under trotting. The major attachment parts were the ungula cusp, outer edges, and ungula capsules, and the stress on the ungula was mainly 4.56–24.72 MPa. According to the microstructures of plantar fur and ungula, the corresponding ratio of the rib width and length was 0.65:1, and the corresponding ratio of the rib width and distance was 3:1. In addition, the scales of the plantar fur were very tightly arranged and had large ripples. Based on typical curves, an ungula capsule-curved surface, and a nonsmooth plantar fur surface, four types of bionic feet and the corresponding ordinary multidamboard foot were designed. On the frozen soil, the bionic foot with ribs and an ungula capsule showed the best attachment performance. Compared with the multidamboard foot, the dynamic coefficient of friction of the bionic foot with ribs and ungula capsules increased by 11.43–31.75%. The attachment mechanism of the bionic feet is as follows: under the action of pressure, the fine patterns of the bionic convex-crown generate friction with the nonsmooth structure of the frozen soil surface, which improves the attachment performance.

22 November 2025 in Biomimetics
Verified
Journal Article
Open access
PDF file
QCQiang Cao
Qiang Cao
WSWenhao Shan
Wenhao Shan
强曹强 曹
强 曹
YYYongqi Yuan
Yongqi Yuan
This study aims to evaluate the kinematic performance of two shoulder rehabilitation exoskeleton configurations to address the critical challenge of human–robot compatibility. Utilizing Hunt’s mobility formula and task-specific Jacobian analysis, we developed a closed-chain kinematic model integrating transient glenohumeral joint dynamics, validated through force/torque measurements and ANOVA statistical comparisons. The PPRRRP configuration, featuring orthogonally distributed passive prismatic joints, demonstrated superior performance: 40–60% lower interaction forces (F¯total=2.66 N), near-isotropic manipulability (ellipsoid axis ratio < 1.5), and 60% reduced operational torque (T¯total=0.18 N·m) compared to RRRUP’s universal joint design. These results establish passive DOF optimization as a viable alternative to actuator-dense systems, diverging from conventional approaches like ARMin-III that prioritize active control. The originality lies in bridging theoretical configuration synthesis with empirical validation, offering a replicable framework for compatibility assessment. This work advances rehabilitation robotics by demonstrating that mechanical transparency—achieved through strategic passive joint allocation—enhances natural movement synergy without compromising stability, proposing hypotheses on energy efficiency and isotropy–fatigue correlations for future exploration. Clinical translation and adaptive impedance control integration are identified as critical next steps to optimize patient-specific rehabilitation outcomes.

22 August 2022 in Research Square
Verified
Preprint
Open access
PDF file
QCQiang Cao
Qiang Cao
XLXuanhan Li
Xuanhan Li
JLJianfeng Li
Jianfeng Li
MDMingjie Dong
Mingjie Dong
ZZZekun Zhang
Zekun Zhang
Due to the advantages of high durability, great repeatability and task orientation, the upper extremity rehabilitation robots have become a gospel for the rehabilitation treatment of stroke patients. The evaluation system for the comfort performance of rehabilitation robots has always been a research hotspot, and how to calculate the human-robot interaction forces is a challenge for the comfort evaluation. In this article, a four degrees of freedom (4-DOFs) upper extremity robot mechanism that is kinematically compatible with the upper limb is presented. Then, taking this mechanism as the research object, an algorithm for estimating human-robot interaction forces is addressed based on Newton-Euler dynamic. Subsequently, a prototype of the proposed robot is developed, and a comparison experiment of interaction forces is carried out on the prototype. The comparative experimental outcomes indicate that the presented algorithm for calculating the human-robot interaction forces is feasible. The findings of this paper provide a prerequisite for the evaluation of the robot comfort, which is of great practical significance.