Katharina Rippel

Dr. Katharina Rippel

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 January 2022 in European Journal of Radiology
Verified
Journal Article
Closed access
JDJosua A. Decker
Josua A. Decker
SBStefanie Bette
Stefanie Bette
NLNora Lubina
Nora Lubina
KRKatharina Rippel
Katharina Rippel
FBFranziska M. Braun
Franziska M. Braun
FSFlorian Schwarz
Florian Schwarz

1 December 2022 in Radiology
Verified
Journal Article
Closed access
JDJosua A. Decker
Josua A. Decker
AHAdrian Huber
Adrian Huber
FSFevzi Senel
Fevzi Senel
SBStefanie Bette
Stefanie Bette
FBFranziska Braun
Franziska Braun
FSFlorian Schwarz
Florian Schwarz
See also the editorial by Dodd and MacDermott in this issue.

1 April 2021 in European Journal of Radiology
Verified
Journal Article
Closed access
HRHannes Ruhnke
Hannes Ruhnke
BJBertram Jehs
Bertram Jehs
FSFlorian Schwarz
Florian Schwarz
MHMark Haerting
Mark Haerting
KRKatharina Rippel
Katharina Rippel
CSChristian Scheurig-Muenkler
Christian Scheurig-Muenkler

21 February 2024 in Journal of Endovascular Therapy
Verified
Journal Article
Open access
KRKatharina Rippel
Katharina Rippel
JLJ. Luitjens
J. Luitjens
OHO. Habeeballah
O. Habeeballah
CSChristian Scheurig-Muenkler
Christian Scheurig-Muenkler
SBStefanie Bette
Stefanie Bette
JDJ. A. Decker
J. A. Decker
Purpose: The aim of this study was to evaluate the radiation dose, image quality, and the potential of virtual monoenergetic imaging (VMI) reconstructions of high-pitch computed tomography angiography (CTA) of the thoracoabdominal aorta on a dual-source photon-counting detector–CT (PCD-CT) in comparison with an energy-integrating detector–CT (EID-CT), with a special focus on low-contrast attenuation. Methods: Consecutive patients being referred for an electrocardiogram (ECG)-gated, high-pitch CTA of the thoracoabdominal aorta prior to transcatheter aortic valve replacement (TAVR), and examined on the PCD-CT, were included in this prospective single-center study. For comparison, a retrospective patient group with ECG-gated, high-pitch CTA examinations of the thoracoabdominal aorta on EID-CT with a comparable scan protocol was matched for gender, body mass index, height, and age. Virtual monoenergetic imaging reconstructions from 40 to 120 keV were performed. Enhancement and noise were measured in 7 vascular segments and the surrounding air as mean and standard deviation of CT values. The radiation dose was noted and signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. Finally, a subgroup analysis was performed, comparing VMI reconstructions from 40 keV to 70 keV in patients with at least a 50% decrease in contrast attenuation between the ascending aorta and femoral arteries. Results: Fifty patients (mean age 77.0±14.5 years; 31 women) were included. The radiation dose was significantly lower on the PCD-CT (4.2±1.4 vs. 7.2±2.2 mGy; p<0.001). With increasing keV, vascular noise, SNR, and CNR decreased. Intravascular attenuation was significantly higher on VMI at levels from 40 to 65, compared with levels of 120 keV (p<0.01 and p<0.005, respectively). On the PCD-CT, SNR was significantly higher in keV levels 40 and 70 (all p<0.001), and CNR was higher at keV levels 40 and 45 (each p<0.001), compared with scans on the EID-CT. At VMI ≤60 keV, image noise was also significantly higher than that in the control group. The subgroup analysis showed a drastically improved diagnostic performance of the low-keV images in patients with low-contrast attenuation. Conclusion: The ECG-gated CTA of the thoracoabdominal aorta in high-pitch mode on PCD-CT have significantly lower radiation dose and higher objective image quality than EID-CT. In addition, low-keV VMI can salvage suboptimal contrast studies, further reducing radiation dose by eliminating the need for repeat scans. Clinical Impact: ECG-gated CT-angiographies of the thoracoabdominal aorta can be acquired with a lower radtiation dose and a better image quality by using a dual-source photon-countinge detector CT. Furthermore, the inherent spectral data offers the possiblity to improve undiagnostic images and thus saves the patient from further radiation and contrast application.

4 January 2024 in The International Journal of Cardiovascular Imaging
Verified
Journal Article
Open access
PDF file
FRFranka Risch
Franka Risch
EHEva Harmel
Eva Harmel
KRKatharina Rippel
Katharina Rippel
BWBastian Wein
Bastian Wein
PRPhilip Raake
Philip Raake
JDJosua A. Decker
Josua A. Decker
The aim of our study was to evaluate two different virtual non-contrast (VNC) algorithms applied to photon counting detector (PCD)-CT data in terms of noise, effectiveness of contrast media subtraction and aortic valve calcium (AVC) scoring compared to reference true non-contrast (TNC)-based results. Consecutive patients underwent TAVR planning examination comprising a TNC scan, followed by a CTA of the heart. VNC series were reconstructed using a conventional (VNCconv) and a calcium-preserving (VNCpc) algorithm. Noise was analyzed by means of the standard deviation of CT-values within the left ventricle. To assess the effectiveness of contrast media removal, heart volumes were segmented and the proportion of their histograms > 130HU was taken. AVC was measured by Agatston and volume score. 41 patients were included. Comparable noise levels to TNC were achieved with all VNC reconstructions. Contrast media was effectively virtually removed (proportions > 130HU from 81% to < 1%). Median calcium scores derived from VNCconv underestimated TNC-based scores (up to 74%). Results with smallest absolute difference to TNC were obtained with VNCpc reconstructions (0.4 mm, Br36, QIR 4), but with persistent significant underestimation (median 29%). Both VNC algorithms showed near-perfect (r²>0.9) correlation with TNC. Thin-slice VNC reconstructions provide equivalent noise levels to standard thick-slice TNC series and effective virtual removal of iodinated contrast. AVC scoring was feasible on both VNC series, showing near-perfect correlation, but with significant underestimation. VNCpc with 0.4 mm slices and Br36 kernel at QIR 4 gave the most comparable results and, with further advances, could be a promising replacement for additional TNC.

4 December 2024 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
KRKatharina Rippel
Katharina Rippel
HRHannes Ruhnke
Hannes Ruhnke
BJBetram Jehs
Betram Jehs
MHMark Haerting
Mark Haerting
JDJosua A. Decker
Josua A. Decker
CSChristian Scheurig-Muenkler
Christian Scheurig-Muenkler
Background/Objectives: To evaluate the differences in treatment and outcomes between traumatic and atraumatic splenic lacerations. Methods: This retrospective study included all patients with a diagnosis of splenic lacerations confirmed by computed tomography that presented from 01/2010 to 03/2023 at one tertiary hospital. The exclusion criteria included missing image data and death in the first 24 h due to extensive trauma. The etiology of the splenic laceration, demographic characteristics, and clinical parameters were recorded and evaluated as prognostic factors in therapy success and mortality. Subgroup analyses were undertaken according to the etiology of the splenic laceration and the primary treatment. The extent of splenic laceration was assessed by using the American Association for the Surgery of Trauma (AAST) score in its latest revision (2018). Results: Of all 291 enrolled patients (mean age 47 ± 21 years, 204 males), 50 presented with atraumatic splenic lacerations due to different underlying causes. The occurrence of moderate and high-grade laceration differed significantly between the atraumatic and traumatic study group (45/50 [90%] vs. 139/241 [58%], p < 0.001). Accordingly, the number of patients being treated conservatively differed greatly (20/50 [40%] vs. 164/241 [56%]), with a worse clinical success rate for atraumatic lacerations (75% vs. 94.5%). Atraumatic splenic injuries showed a higher conversion rate to surgery (2/20 [10%] vs. 2/164 [1%]). Despite the lower clinical success rate of splenic artery embolization (SAE) in atraumatic injuries (87% vs. 97%), the number of patients needing treatment for primary SAE in AAST 3 injuries was 14.1 in the traumatic population and only 4 in the atraumatic population. Conclusions: Atraumatic splenic injuries should not be treated as traumatic splenic injuries. An early upgrade to SAE or surgery should be considered for moderate splenic injuries, and they should be evaluated by an interdisciplinary team on a case-by-case basis. However, due to the underlying multimorbidity of patients with atraumatic splenic injuries, a higher mortality is to be expected.