Javier Delgado Gonzaga

Dr. Javier Delgado Gonzaga

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 January 2025 in Processes
Verified
Journal Article
Open access
PDF file
JGJavier Delgado Gonzaga
Javier Delgado Gonzaga
WRWilfrido Rivera
Wilfrido Rivera
J. Camilo Jiménez GarcíaJ. Camilo Jiménez García
J. Camilo Jiménez García
APAlejandro Pacheco
Alejandro Pacheco
DRDavid Juárez Romero
David Juárez Romero
This study proposes a cogeneration system for the simultaneous production of cooling and freshwater. A double-stage cascade compression cooling system consists of two interconnected vapor compression cycles. The proposed system integrates a double-stage cascade compression cooling system with a water desalination unit, which takes advantage of the heat released by the cascade system. The system performance was evaluated using various refrigerants selected based on their energy efficiency, environmental impact, and widespread use. Multiple combinations of the fluids were used in the high-temperature cycle (HTC) and low-temperature cycle (LTC) to analyze their impact on system performance. A parametric analysis was conducted by developing a mathematical model in MATLAB. The model’s input parameters were the evaporation temperature and the temperature difference between the inlet and discharge of both compressors (ΔLTC and ΔHTC). System performance was assessed from a first-law point of view through the coefficient of performance (COP), the energy utilization factor (EUF), and the gain output ratio (GOR). The results revealed that the maximum (105 °C) and minimum (−13 °C) temperatures, essential for desalination and cooling, respectively, were achieved using R134a in the LTC and R123 in the HTC, with ΔLTC = 65 °C and ΔHTC = 70 °C. However, the best performance was observed with R123 in both cycles, with ΔLTC = 45 °C and ΔHTC = 70 °C. This configuration achieved a COP of 1.06, a GOR of 1.61, and an EUF of 2.74.

26 January 2023 in International Journal of Chemical Reactor Engineering
Verified
Journal Article
Closed access
DRDavid Juárez Romero
David Juárez Romero
IRIrán Ortiz Rivera
Irán Ortiz Rivera
ISIsaac Justine Canela Sánchez
Isaac Justine Canela Sánchez
NMNancy Isamar Ortega Mojica
Nancy Isamar Ortega Mojica
Armando Thermal HuicocheaArmando Thermal Huicochea
Armando Thermal Huicochea
JGJavier Delgado Gonzaga
Javier Delgado Gonzaga
The purpose of this work is to evaluate the performance of a rough-textured evaporator applied to a single-stage absorption heat transformer for water desalination (SAHT-WD). The stainless-steel evaporator was subjected to an abrasive material release treatment (sandblast texture) to provide a texture that fosters phase change heat transfer compared to a smooth surface. To determine the performance of the evaporator, the evaluation has been divided into an experimental and a theoretical analysis. The experimental analysis focused on determining the operating conditions that favor the performance of the evaporator and the SAHT-WD. For the theoretical analysis, a mathematical model was developed to predict the wetting efficiency and the heat-transfer coefficients of the evaporator. To quantify the improvement in the performance of the rough-surface evaporator, the experimental results were compared with those reported in a reference work. The results indicate that the sandblasted texture improved the performance of the evaporator as well as that of the SAHT-WD. The results of the mathematical model suggest that the rough tube improved the wetting efficiency of the evaporator.

20 October 2024 in Processes
Verified
Journal Article
Open access
PDF file
SGSANDRO GUADALUPE PEREZ GRAJALES
SANDRO GUADALUPE PEREZ GRAJALES
TOTeresa Hernández Ortíz
Teresa Hernández Ortíz
RORogelio Martínez Oropeza
Rogelio Martínez Oropeza
TTTabai Torres-Díaz
Tabai Torres-Díaz
LLLuis Adrián López-Pérez
Luis Adrián López-Pérez
DRDavid Juárez Romero
David Juárez Romero
Solar energy is one of the main renewable energy resources due to its abundance. It can be used for two purposes, thermal or photovoltaic applications. However, when the resource obtained is mixed, it is called photovoltaic thermal hybrid, where the solar panels generate electricity and are provided with a heat exchanger to absorb energy through a water flow. This is one of the techniques used by the scientific community to reduce the excess temperature generated by solar radiation in the cells, improving the electrical efficiency of photovoltaic systems and obtaining fluid with higher temperature. In this work, the thermal behavior of a heat exchanger equipped with fins in its interior to increase the thermal efficiency of the system was analyzed using CFD (Computational Fluid Dynamics). The results showed that the average fluid outlet temperature was 75.31 °C, considering an incident irradiance of 1067 W/m2 and a fluid inlet temperature of 27 °C. The operating conditions were obtained from published experimental studies, achieving 97.7% similarity between the two. This was due to the boundary conditions of the heat flux (1067 W/m2) impinging directly on the coupled cells and the heat exchanger in a working area of 0.22 m2.

1 January 2025 in Revista Facultad de Ingeniería Universidad de Antioquia
Verified
Journal Article
Closed access
UMUniversidad Autónoma del Estado de Morelos
Universidad Autónoma del Estado de Morelos
LÁLailani Álvarez
Lailani Álvarez
MBMayra Harumi Bello-Guadarrama
Mayra Harumi Bello-Guadarrama
NONancy Isamar Ortega-Mojica
Nancy Isamar Ortega-Mojica
APArianna Parrales-Bahena
Arianna Parrales-Bahena
DRDavid Juárez Romero
David Juárez Romero
The increasing awareness about energy conservation and its implications for a company's profitability has led to the creation of several models that combine energy processes with cost-accounting methods. Consequently, the industry has centered its endeavors on identifying economically viable, technologically possible, and environmentally acceptable alternatives. An approach to addressing the above issues is to conduct an exergoeconomic analysis of the energy systems implemented during operations to maximize resource use. The present research evaluates the use of exergonomic analysis in an Absorption Heat Transformer (AHT) to identify areas for improvement in system operation and to optimize the essential parameters for improved technological efficiency. The study also found possible ways to make the generator (GE), economizer (EC), and absorber (AB) better for future research, while still reaching up to 98% technical efficiency in some parts. Considering cost as a measure of used resources provides a thorough insight into the energy systems adopted by the industry. Thanks to the fact that exergonomics considers costs as a measure of resource consumption, this approach offers a comprehensive view of the energy systems adopted by the industry. These results are relevant for understanding the potential impact of integrating technical, economic, and environmental efficiency into energy management practices within the industrial sector.

14 May 2025 in Processes
Verified
Journal Article
Open access
PDF file
APAlejandro Pacheco
Alejandro Pacheco
J. Camilo Jiménez GarcíaJ. Camilo Jiménez García
J. Camilo Jiménez García
JGJavier Delgado Gonzaga
Javier Delgado Gonzaga
WRWilfrido Rivera
Wilfrido Rivera
More efficient energy conversion systems operating with clean energy sources or utilizing waste heat are crucial to minimizing the negative environmental impact associated with conventional systems. This study presents the energy and exergy analysis of a modified heat pump capable of producing cooling and desalinated water using heat dissipated in the condenser. Six refrigerants were analyzed in the theoretical evaluation of the proposed system. These were selected based on their use in vapor compression systems and their thermodynamic properties. A parametric study considering operating temperatures and relative humidities determined that refrigerant R-123 achieved the greatest benefits in terms of the EER, the GOR, and ηExergy. In contrast, the highest benefits in water desalination were obtained with refrigerant R-410a. For operating conditions of TE = 0 °C, TC = 34 °C, and TCA = 14 °C, the system using refrigerant R-123 achieved an EER, GOR, ηExergy, DW, and IT of 0.82, 2.51, 0.35, 3.46 L/h, and 0.55 kW, respectively. Additionally, the dehumidifier and the evaporator were the components contributing the highest irreversibilities, accounting for approximately 24% and 19.3%, respectively.