Konstantin V. Sergienko

Mr. Konstantin V. Sergienko

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 November 2019 in Nanomaterials
Verified
Journal Article
Open access
PDF file
ENElena O. Nasakina
Elena O. Nasakina
MSMaria A. Sudarchikova
Maria A. Sudarchikova
KSKonstantin V. Sergienko
Konstantin V. Sergienko
SKSergey V. Konushkin
Sergey V. Konushkin
M.A. SevostyanovM.A. Sevostyanov
M.A. Sevostyanov
The corrosion resistance of nanostructured nitinol (NiTi) was investigated using long-term tests in solutions simulating physiological fluids at static conditions, reflecting the material structure and metal concentration in the solutions. Mechanical polishing reduced the ion release by a factor of two to three, whereas annealing deteriorated the corrosion resistance. The depassivation and repassivation of nitinol surfaces were considered. We found that nanostructured nitinol might increase the corrosion leaching of titanium into solutions, although the nickel release decreased. Metal dissolution did not occur in the alkaline environment or artificial plasma. A Ni-free surface with a protective 25 nm-thick titanium oxide film resulted from soaking mechanically treated samples of the NiTi wire in a saline solution for two years under static conditions. Hence, the medical application of nanostructured NiTi, such as for the production of medical devices and implants such as stents, shows potential compared with microstructured NiTi.

20 November 2024 in Metals
Verified
Journal Article
Open access
PDF file
KSKonstantin V. Sergienko
Konstantin V. Sergienko
SKSergey V. Konushkin
Sergey V. Konushkin
MKMikhail A Kaplan
Mikhail A Kaplan
AGArtyom Dmitrievich Gorbenko
Artyom Dmitrievich Gorbenko
YGYucheng Guo
Yucheng Guo
AKAlexey G. Kolmakov
Alexey G. Kolmakov
The work described in this article is aimed at investigating the properties of a group of Ti-Zr-Nb alloys. In modern orthopedics and traumatology, the use of materials for bone implants with a minimum modulus of elasticity is becoming increasingly important. This is due to a number of advantages that allow for better integration of the implants with the bone tissue, including the reduction in the detrimental effect of the load-shielding effect, a better load distribution, and stress distribution, which allows for increasing the life of the implant. It is known that the lowest modulus of elasticity in titanium alloys at normal temperature is achieved by the phase composition consisting of metastable β-phase. It is possible to achieve the desired structure by a combination of alloy composition selection and heat treatment. Quenching of titanium alloys allows for the high-temperature β-phase to be fixed. This paper provides justification of the choice of compositions of the studied alloys by calculation methods. The structure of alloys after melting in a vacuum electric arc furnace in an argon environment was studied. The ingots obtained had a dendritic structure. Homogenizing annealing in a vacuum furnace at 1000 °C for 4 h was used to equalize the composition. The structure of the alloyed sheets after hot rolling and hot rolling and quenching was investigated. The microstructure of the plates in both variants had uniform grains of polyhedral shape. X-ray phase analysis of the plates showed that the content of metastable β-phase was 100% before and after quenching. Microhardness testing of the plates showed no significant effect of quenching. The result of the mechanical properties study showed an increase in the plasticity of the material after quenching, with the tensile plots of the samples after quenching reflecting the area where the reverse phase transition of β’<-> α’’ occurs. Mechanical studies by cyclic loading showed the presence of a superelasticity effect. The Young’s modulus study gave a result of 51 GPa for one of the compositions studied. The combination of properties of the materials under investigation has the potential for promising use as a basis for bone implants.

1 September 2018 in Doklady Chemistry
Verified
Journal Article
Closed access
PDF file
M.A. SevostyanovM.A. Sevostyanov
M.A. Sevostyanov
ABAlexander Sergeevich Baikin
Alexander Sergeevich Baikin
LSL. A. Shatova
L. A. Shatova
ENElena O. Nasakina
Elena O. Nasakina
ABAlexey V. Berezhnov
Alexey V. Berezhnov
AKAlexey G. Kolmakov
Alexey G. Kolmakov
Titanium-based alloy with low-toxic metals such as niobium, tantalum and zirconium (TiNbTaZr) was manufactured. The primary weight percentages of elements used for fusion were: titanium, 65%;...

27 April 2018 in IOP Conference Series: Materials Science and Engineering
Verified
Conference Paper
Open access
PDF file
KSKonstantin V. Sergienko
Konstantin V. Sergienko
MSM A Sevost’yanov
M A Sevost’yanov
SKS V Konushkin
S V Konushkin
ENElena O. Nasakina
Elena O. Nasakina
ABA S Baikin
A S Baikin
AKA G Kolmakov
A G Kolmakov

Verified
Journal Article
Open access
PDF file
KSKonstantin V. Sergienko
Konstantin V. Sergienko
SKSergey V. Konushkin
Sergey V. Konushkin
YMYaroslava Morozova
Yaroslava Morozova
MKMikhail A Kaplan
Mikhail A Kaplan
AGArtyom Dmitrievich Gorbenko
Artyom Dmitrievich Gorbenko
M.A. SevostyanovM.A. Sevostyanov
M.A. Sevostyanov
Hip joint implants are among the most prevalent types of medical implants utilized for the replacement of damaged joints. The utilization of modern implant materials, such as cobalt–chromium alloys, stainless steel, titanium, and other titanium alloys, is accompanied by challenges, including the toxicity of certain elements (e.g., aluminum, vanadium, nickel) and excessive Young’s modulus, which adversely impact biomechanical compatibility. A mismatch between the stiffness of the implant material and the bone tissue, known as stress shielding, can lead to adverse outcomes such as bone resorption and implant loosening. Recent studies have shifted the focus to β-titanium alloys due to their exceptional biocompatibility, corrosion resistance, and low Young’s modulus, which is close to the Young’s modulus of bone tissue (10–30 GPa). In this study, the microstructure, mechanical properties, and phase stability of the Ti-38Zr-11Nb alloy were investigated. Energy dispersion spectrometry was employed to confirm the homogeneous distribution of Ti, Zr, and Nb in the alloy. A subsequent microstructural analysis revealed the presence of elongated β-grains subsequent to rolling and quenching. Furthermore, grinding contributed to the process of recrystallization and the formation of subgrains. X-ray diffraction analysis confirmed the presence of a stable β-phase under any heat treatment conditions, which can be explained by the use of Nb as a β-stabilizer and Zr as a neutral element with a weak β-stabilizing effect in the presence of other β-stabilizers. Furthermore, the modulus of elasticity, as determined by tensile testing, exhibited a decline from 85 GPa to 81 GPa after annealing. Mechanical tests demonstrated a substantial enhancement in tensile strength (from 529 MPa to 628 MPa) concurrent with a 32% reduction in elongation to fracture of the samples. These alterations are attributed to microstructural transformations, including the formation of subgrains and the rearrangement of dislocations. This study’s findings suggest that the Ti-38Zr-11Nb alloy has potential as a material of choice due to its lower Young’s modulus compared to traditional materials and its stable β-phase, which enhances the implant’s durability and reduces the risk of brittle phases forming over time. This study demonstrates that the corrosion resistance of titanium grade 2 and Ti-38Zr-11Nb is comparable. The material in question exhibited no evidence of cytotoxic activity in the context of mammalian cells.

7 January 2023 in Coatings
Verified
Journal Article
Open access
PDF file
ENElena O. Nasakina
Elena O. Nasakina
MSMaria Sudarchikova
Maria Sudarchikova
DKDemin Konstantin
Demin Konstantin
AMA. Mikhailova
A. Mikhailova
KSKonstantin V. Sergienko
Konstantin V. Sergienko
AKAlexey G. Kolmakov
Alexey G. Kolmakov
Composite materials "base–transition layer–surface metal layer (Ta/Ti)" were produced using a complex vacuum technology including magnetron sputtering. The structure (by scanning electron microscopy, Auger electron spectroscopy, X-ray diffractometry) and mechanical properties were studied. An almost linear increase in the thickness of both the surface and transition layers was observed with increasing deposition time and power; however, the growth of the surface layer slowed down with increasing power above some critical value. The transition zone with the growth of time stopped growing upon reaching about 300 nm and was formed approximately 2 times slower than the surface one (and about 3.5 times slower with power). It was noted that with equal sputtering–deposition parameters, the layer growth rates for tantalum and titanium were the same. In the sample with a Ta surface layer deposited on titanium, a strongly textured complex structure with alpha and beta Ta was observed, which is slightly related to the initial substrate structure and the underlying layer. However, even at small thicknesses of the surface layer, the co-deposition of tantalum and titanium contributes to the formation of a single tantalum phase, alpha.