Yaroslava Morozova

Ms. Yaroslava Morozova

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 November 2024 in Metals
Verified
Journal Article
Open access
PDF file
KSKonstantin V. Sergienko
Konstantin V. Sergienko
SKSergey V. Konushkin
Sergey V. Konushkin
MKMikhail A Kaplan
Mikhail A Kaplan
AGArtyom Dmitrievich Gorbenko
Artyom Dmitrievich Gorbenko
YGYucheng Guo
Yucheng Guo
AKAlexey G. Kolmakov
Alexey G. Kolmakov
The work described in this article is aimed at investigating the properties of a group of Ti-Zr-Nb alloys. In modern orthopedics and traumatology, the use of materials for bone implants with a minimum modulus of elasticity is becoming increasingly important. This is due to a number of advantages that allow for better integration of the implants with the bone tissue, including the reduction in the detrimental effect of the load-shielding effect, a better load distribution, and stress distribution, which allows for increasing the life of the implant. It is known that the lowest modulus of elasticity in titanium alloys at normal temperature is achieved by the phase composition consisting of metastable β-phase. It is possible to achieve the desired structure by a combination of alloy composition selection and heat treatment. Quenching of titanium alloys allows for the high-temperature β-phase to be fixed. This paper provides justification of the choice of compositions of the studied alloys by calculation methods. The structure of alloys after melting in a vacuum electric arc furnace in an argon environment was studied. The ingots obtained had a dendritic structure. Homogenizing annealing in a vacuum furnace at 1000 °C for 4 h was used to equalize the composition. The structure of the alloyed sheets after hot rolling and hot rolling and quenching was investigated. The microstructure of the plates in both variants had uniform grains of polyhedral shape. X-ray phase analysis of the plates showed that the content of metastable β-phase was 100% before and after quenching. Microhardness testing of the plates showed no significant effect of quenching. The result of the mechanical properties study showed an increase in the plasticity of the material after quenching, with the tensile plots of the samples after quenching reflecting the area where the reverse phase transition of β’<-> α’’ occurs. Mechanical studies by cyclic loading showed the presence of a superelasticity effect. The Young’s modulus study gave a result of 51 GPa for one of the compositions studied. The combination of properties of the materials under investigation has the potential for promising use as a basis for bone implants.

Verified
Journal Article
Open access
PDF file
KSKonstantin V. Sergienko
Konstantin V. Sergienko
SKSergey V. Konushkin
Sergey V. Konushkin
YMYaroslava Morozova
Yaroslava Morozova
MKMikhail A Kaplan
Mikhail A Kaplan
AGArtyom Dmitrievich Gorbenko
Artyom Dmitrievich Gorbenko
M.A. SevostyanovM.A. Sevostyanov
M.A. Sevostyanov
Hip joint implants are among the most prevalent types of medical implants utilized for the replacement of damaged joints. The utilization of modern implant materials, such as cobalt–chromium alloys, stainless steel, titanium, and other titanium alloys, is accompanied by challenges, including the toxicity of certain elements (e.g., aluminum, vanadium, nickel) and excessive Young’s modulus, which adversely impact biomechanical compatibility. A mismatch between the stiffness of the implant material and the bone tissue, known as stress shielding, can lead to adverse outcomes such as bone resorption and implant loosening. Recent studies have shifted the focus to β-titanium alloys due to their exceptional biocompatibility, corrosion resistance, and low Young’s modulus, which is close to the Young’s modulus of bone tissue (10–30 GPa). In this study, the microstructure, mechanical properties, and phase stability of the Ti-38Zr-11Nb alloy were investigated. Energy dispersion spectrometry was employed to confirm the homogeneous distribution of Ti, Zr, and Nb in the alloy. A subsequent microstructural analysis revealed the presence of elongated β-grains subsequent to rolling and quenching. Furthermore, grinding contributed to the process of recrystallization and the formation of subgrains. X-ray diffraction analysis confirmed the presence of a stable β-phase under any heat treatment conditions, which can be explained by the use of Nb as a β-stabilizer and Zr as a neutral element with a weak β-stabilizing effect in the presence of other β-stabilizers. Furthermore, the modulus of elasticity, as determined by tensile testing, exhibited a decline from 85 GPa to 81 GPa after annealing. Mechanical tests demonstrated a substantial enhancement in tensile strength (from 529 MPa to 628 MPa) concurrent with a 32% reduction in elongation to fracture of the samples. These alterations are attributed to microstructural transformations, including the formation of subgrains and the rearrangement of dislocations. This study’s findings suggest that the Ti-38Zr-11Nb alloy has potential as a material of choice due to its lower Young’s modulus compared to traditional materials and its stable β-phase, which enhances the implant’s durability and reduces the risk of brittle phases forming over time. This study demonstrates that the corrosion resistance of titanium grade 2 and Ti-38Zr-11Nb is comparable. The material in question exhibited no evidence of cytotoxic activity in the context of mammalian cells.

1 April 2024 in Inorganic Materials: Applied Research
Verified
Journal Article
Closed access
PDF file
SKS. V. Konushkin
S. V. Konushkin
MKMikhail A Kaplan
Mikhail A Kaplan
KSKonstantin V. Sergienko
Konstantin V. Sergienko
AGArtyom Dmitrievich Gorbenko
Artyom Dmitrievich Gorbenko
YMYaroslava Morozova
Yaroslava Morozova
MSM. A. Sevostyanov
M. A. Sevostyanov
The production of homogeneous Ti–10Nb–(1–3)Mo (at %) alloys in the form of semifinished products (plates) was studied through multiple remeltings and homogenization annealing. Metallographic studies of the resulting materials in cast, rolled, and annealed states were carried out. The effect of annealing and composition on the structure, phase composition, and mechanical properties of the Ti–10Nb–(1–3)Mo alloy was revealed. Homogeneity after smelting was achieved by annealing at a temperature of 950°C for 12 h. An increase in the Mo content in the Ti–10Nb–(1–3)Mo alloy led to an increase in the strength of the alloys, while the ductility decreased. The achievement of high strength characteristics in selected alloys was associated with the development of annealing parameters after plastic deformation, namely, controlling the size of recrystallized grains and separating the α and β phases. In addition to α-Ti and β-Ti, the samples contained small amounts of ω-Ti, which led to a sharp increase in the hardness of the samples.

1 January 2020 in Journal of Physics: Conference Series
Verified
Conference Paper
Open access
PDF file
KSKonstantin V. Sergienko
Konstantin V. Sergienko
YMYaroslava Morozova
Yaroslava Morozova
ATA M Tsareva
A M Tsareva
In this work, a TiNiTa wire with a tantalum content of 10% (weight) was obtained, heat treatment of wire samples was carried out at various temperatures in a vacuum furnace, mechanical tests were carried out after heat treatment to determine the optimal heat treatment mode after the final drawing step to remove hardening and obtain the best complex mechanical properties for the use of wire in the manufacture of medical stents.

Verified
Journal Article
Open access
PDF file
KSKonstantin V. Sergienko
Konstantin V. Sergienko
SKSergey V. Konushkin
Sergey V. Konushkin
YMYaroslava Morozova
Yaroslava Morozova
MSMaria Sudarchikova
Maria Sudarchikova
MKMikhail A Kaplan
Mikhail A Kaplan
AKAlexey G. Kolmakov
Alexey G. Kolmakov
The research described in this article is a continuation of a series of studies on biocompatible materials, focused on finding the optimal alloy composition and heat treatment regimes. The use of materials with a low Young’s modulus ensures the long-term safety of the implant by reducing the stress shielding effect, which causes bone resorption. This work investigates the effect of alloying with niobium in the range of (8–10) at. % on the Ti-38Zr alloy, specifically its structure, mechanical properties, Young’s modulus, and superelasticity. In this study, plates of the Ti-38Zr-(8-10)Nb (at. %) alloy were investigated after quenching and subsequent annealing. In Ti-38Zr-(8-10)Nb alloys, quenching from 600 °C fixes the β-phase of Ti. In alloys with (8-9)Nb, this is a metastable β-phase, as evidenced by its superelastic behavior under cyclic tension. Annealing at 400 °C leads to a clear decomposition of the quenched high-temperature β-phase in Ti-38Zr-(8-9)Nb alloys into β- and α′-phases. Based on the mechanical test results, it can be inferred that the precipitation of the brittle ω-phase and the α′-phase occur concurrently, since annealing at 400 °C causes a pronounced embrittlement of the Ti-38Zr-(8–9)Nb alloys (with elongation dropping from ~15% to 0.7–2.5%, respectively) alongside a substantial increase in strength (from 500 MPa to 1010 MPa). For the Ti-38Zr-10Nb alloy, the ductility also declines but remains within acceptable limits (from ~14% to ~10%), while the strength rises from 520 MPa to 630 MPa. The Young’s modulus of the Ti-38Zr-(8-10)Nb alloy after quenching is ~80 GPa. After annealing, it increases to 95 GPa for alloys with (8-9)Nb, while for 10Nb it remains at approximately 80 GPa.

24 February 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
KSKonstantin V. Sergienko
Konstantin V. Sergienko
SKSergey V. Konushkin
Sergey V. Konushkin
YMYaroslava Morozova
Yaroslava Morozova
MKMikhail A Kaplan
Mikhail A Kaplan
AGArtyom Dmitrievich Gorbenko
Artyom Dmitrievich Gorbenko
M.A. SevostyanovM.A. Sevostyanov
M.A. Sevostyanov
Hip joint implants are one of the most common types of medical implants used to replace a damaged joint and restore its functional activity. Hundreds of thousands of surgeries are performed annually to install them, which underscores the importance of developing and improving materials for such implants. Modern materials for implants, including co-balt-chromium alloys, stainless steel, titanium and other titanium alloys, face problems such as the toxicity of certain elements (for example, aluminum, vanadium, nickel) and excessive Young's modulus, which negatively affects biomechanical compatibility. A mismatch between the stiffness of the implant material and the bone tissue, called stress shielding, can lead to bone resorption and loosening of the implant. Recent studies have shifted the focus to β-titanium alloys due to their exceptional biocompatibility, corrosion resistance, and low Young's modulus, which is close to the Young's modulus of bone tis-sue (10-30 GPa). Among them, Ti-38Zr-11Nb alloy is promising for use as an implant material. In this study, the microstructure, mechanical properties, and phase stability of Ti-38Zr-11Nb alloy were studied. Energy dispersion spectrometry confirmed the homo-geneous distribution of Ti, Zr, and Nb in the alloy. Microstructural analysis revealed elongated β-grains after rolling and quenching, and grinding contributed to recrystalliza-tion and the formation of subgrains. X-ray diffraction analysis confirmed the presence of a stable β-phase under any heat treatment conditions, which is explained by the use of Nb as a β-stabilizer and Zr as a neutral element with a weak β-stabilizing effect in the pres-ence of other β-stabilizers. The modulus of elasticity after annealing decreased from 85 GPa to 81 GPa. Mechanical tests showed a significant increase in tensile strength (from 529 MPa to 628 MPa) simultaneously with a 32% decrease in elongation to fracture of the samples. These changes are caused by microstructural transformations such as the for-mation of subgrains and rearrangement of dislocations. Based on the results of the study, it can be concluded that Ti-38Zr-11Nb alloy is a promising material due to its lower low Young's modulus relative to the classical materials used and stable β-phase, which pro-vides the possibility of long-term use of the implant, without the risk of formation of brittle phases.