The primary objective of this investigation is to assess the influence of a mandible implant on the electric field distribution and the specific absorption rate (SAR) within the cell phone user’s head. The procedure is based on numerically solving the electromagnetic propagation equation. This is an effective technique for the assessment of electric field distribution and the energy levels absorbed by the organs inside the head. In order to accomplish this, realistic three-dimensional head, implant, and mobile phone models are developed. The frequency applied in the simulations is 2600 MHz. Electric field strength and SAR distributions within the head are presented and examined. A comparative analysis was performed on both models, with and without a titanium mandible implant, to assess the influence of the implant on neighboring biological tissues. The results indicate that both values rise inside biological tissues close to the mandible implant. Face-to-phone safe distances are identified when the values of the electric field and SAR are under the allowable levels set by regulations.
12 February 2015 in International Journal of Circuit Theory and Applications
The first part of the paper discusses designing of the lowpass filter that gives both a constant group delay over the passband and a sharp cut-off slope, which is one of the most difficult challenges in continuous-time signal processing. Furthermore, equalisation of the group delay distortion of the Chebyshev filter has been performed through a cascade connection of the allpass filters. The Newton–Raphson method is applied for solving the system of nonlinear equations that calculate the allpass filter parameters for equalising the constant group delay in an equiripple sense. This procedure gives nearly symmetric impulse response of the resulting filtering system, as well as a longer duration. In the second part of the paper, two solutions for synthesising polynomial filter transfer functions are discussed: filter with monotonic amplitude characteristic (LSM) and filter using Chebyshev polynomial. For the purpose of comparison, the passband ripple factor of the Chebyshev filter is necessary to be adjusted so that both filters have the same stopband insertion loss, group delay and transient response. It is shown that Chebyshev filter is preferable since the passband magnitude distortions and sensitivity to the element deviation tolerance are significantly superior.
19 October 2011 in Inverse Problems in Science and Engineering
Direct synthesis of recursive digital filters, whose characteristic function belongs to the new IIR filters class, is described in this article. Attenuation characteristic in the passband lies between the Butterworth's and the Elliptic's attenuation characteristics. All zeros of transfer function are placed on the unit circle so that the condition for complementary decomposition is fulfilled. Complementary decomposition into parallel connection of two allpass filters is performed. Then, lowpass filter is obtained summing these two filters and its complementary highpass filter – by their subtraction. The main advantage of this kind of filters is its smaller sensitivity to digital word length change compared to standard filters.
The aim of this study is to estimate the effects of metal frame glasses on the electric field distribution and Specific Absorption Rate (SAR) inside the model of a human head. The numerical solution of the equations of electromagnetic wave propagation has been used to obtain the electric field distribution and values of SAR in the vicinity of the metal frame glasses, exposed to cell phone radiation at the frequency of the 3G mobile network. The assessment of these effects has been performed during the conversation over a mobile phone. In order to obtain the most accurate results, the realistic 3D model of the human head, as well as the model of metal frame glasses have been created. For evaluating the mentioned effects, a comparative analysis of models with and without glasses has been carried out. Therefore, the obtained results are presented within different biological tissues and organs from which the human head model was made.