View All Publications
22 May 2025 in Electronics
Verified
Journal Article
Open access
PDF file
DJDejan Jovanovic
Dejan Jovanovic
DKDragan Krasic
Dragan Krasic
NCNenad Cvetković
Nenad Cvetković
VSVladimir Stanković
Vladimir Stanković
DZDragana Zivaljevic
Dragana Zivaljevic
BPBojana Petkovic
Bojana Petkovic
The primary objective of this investigation is to assess the influence of a mandible implant on the electric field distribution and the specific absorption rate (SAR) within the cell phone user’s head. The procedure is based on numerically solving the electromagnetic propagation equation. This is an effective technique for the assessment of electric field distribution and the energy levels absorbed by the organs inside the head. In order to accomplish this, realistic three-dimensional head, implant, and mobile phone models are developed. The frequency applied in the simulations is 2600 MHz. Electric field strength and SAR distributions within the head are presented and examined. A comparative analysis was performed on both models, with and without a titanium mandible implant, to assess the influence of the implant on neighboring biological tissues. The results indicate that both values rise inside biological tissues close to the mandible implant. Face-to-phone safe distances are identified when the values of the electric field and SAR are under the allowable levels set by regulations.

1 January 2020 in Safety Engineering
Verified
Journal Article
Closed access
PDF file
DJDejan Jovanovic
Dejan Jovanovic
VSVladimir Stanković
Vladimir Stanković
DZDragana Zivaljevic
Dragana Zivaljevic
DVDragan Vučković
Dragan Vučković
SISimona ILIE
Simona ILIE
The aim of this study is to estimate the effects of metal frame glasses on the electric field distribution and Specific Absorption Rate (SAR) inside the model of a human head. The numerical solution of the equations of electromagnetic wave propagation has been used to obtain the electric field distribution and values of SAR in the vicinity of the metal frame glasses, exposed to cell phone radiation at the frequency of the 3G mobile network. The assessment of these effects has been performed during the conversation over a mobile phone. In order to obtain the most accurate results, the realistic 3D model of the human head, as well as the model of metal frame glasses have been created. For evaluating the mentioned effects, a comparative analysis of models with and without glasses has been carried out. Therefore, the obtained results are presented within different biological tissues and organs from which the human head model was made.

20 November 2024 in Electronics
Verified
Journal Article
Open access
PDF file
DZDragana Zivaljevic
Dragana Zivaljevic
DJDejan Jovanovic
Dejan Jovanovic
DKDragan Krasic
Dragan Krasic
NCNenad Cvetković
Nenad Cvetković
BPBojana Petkovic
Bojana Petkovic
The purpose of this study was to determine the impact of a titanium cranial implant on the electric field distribution and the amount of energy absorbed from a cell phone within the human head. Three-dimensional lifelike models of the head of the mobile phone user, a titanium cranial implant, and a smartphone model was built. The head model consisted of sixteen homogeneous, isotropic domains, with permittivity and conductivity parameters taken from the literature. Numerical calculations were performed at the mobile communication frequency of 2600 MHz for a head model with and without a titanium cranial implant, in order to determine a field perturbation introduced by the implant. Our results show that in the presence of a titanium cranial implant, the electric field amplitude and SAR (Specific Absorption Rate) are increased within the layers close to the outer surface of the model (skin, fat tissue, and muscle). On the other hand, a cranial implant leads to a lower penetration depth, decreasing the electric field amplitude and SAR inside the skull, cerebrospinal fluid, and brain.

1 January 2023 in Tehnicki vjesnik - Technical Gazette
Verified
Journal Article
Open access
PDF file
VSVladimir Stanković
Vladimir Stanković
DJDejan Jovanovic
Dejan Jovanovic
MBMilan Blagojevic
Milan Blagojevic
MRMiomir Raos
Miomir Raos
AJAnđela Jevtić
Anđela Jevtić
This paper represents the numerical analysis of Specific Absorption Rate (SAR) and temperature distribution within the eyes of realistic child head model exposed to mobile phone radiation at the frequency of 4G. The SAR and temperature distribution are obtained by numerical solutions of the equation of electromagnetic wave propagation as well as the bioheat equation. The values of SAR and temperature distribution are shown for different biological tissues of the eyes during exposure to electromagnetic radiation from a mobile phone. As electromagnetic properties of tissues depend on the electromagnetic waves' frequency, the value of SAR and temperature will be different for different tissues. For the purpose of this research, a realistic 3D model of a child's head has been created. Maximum absorption of electromagnetic energy occurs in the surface layers of the child head model, whereby this value exceeds the maximum allowed limits. This is the case when the radiation source is positioned closest to the head model. An increase in temperature was observed in the biological tissues and organs closest to the radiation source, i.e. the mobile phone. As the distance between the mobile phone and the child head increases, the temperature decreases, but slower than the SAR values.

21 September 2018 in IET Microwaves, Antennas & Propagation
Verified
Journal Article
Open access
PDF file
NCNenad Cvetković
Nenad Cvetković
DKDejan Krstić
Dejan Krstić
VSVladimir Stanković
Vladimir Stanković
DJDejan Jovanovic
Dejan Jovanovic
The aim of this study is a numerical analysis of the electric field and the specific absorption rate (SAR) distribution within a realistic 3D‐human eye model exposed to electromagnetic (EM) wave of virtual reality (VR) glasses at the frequency of third generation, long‐term evolution‐4G, and the frequency of the latest generation of mobile networks – 5G. To obtain the values of the electric field and SAR, the numerical solution of equations of EM waves propagation has been used. A new realistic 3D‐human head and human eye model has been created. The obtained results are shown for different biological tissues of the eye exposed to EM radiation from VR glasses at different frequencies. The maximum absorption of EM energy will be discussed for the following frequencies: 900 MHz, 2.6 GHz, and 28 GHz. The maximum values of electric field strength in the human eye tissue at the frequencies 28 GHz and 900 MHz are 94.43 and 137.3 V/m, respectively (higher than referent values), whereas for 2.6 GHz amounts 8.62 V/m (lower than referent limits). The obtained SAR peaks do not overcome prescribed safety values.

1 January 2020 in Safety Engineering
Verified
Journal Article
Closed access
PDF file
NCNenad Cvetković
Nenad Cvetković
Marinko BarukčićMarinko Barukčić
Marinko Barukčić
DJDejan Jovanovic
Dejan Jovanovic
The electrical resistance of the grounding system has a highly nonlinear character concerning the geometrical parameters, especially in the case of nonhomogeneous soil. Hence, the optimization procedures for such grounding systems are very complex. In this paper, a co-simulation frame is used for the realization of the mentioned optimization. The frame includes two available computer simulation tools, one designed for numerical simulation of the electromagnetic field and the other one specialized for evolutionary optimization. It is applied on the vertical ground rod electrode and the grounding system consisted of two ring electrodes.