Michal Holub

Dr. Michal Holub

Brno University of Technology, Faculty of mechanical Engineering, Institut of Production Machines, Systems and Robotics
orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2018 in Measurement
Verified
Journal Article
Closed access
Michal HolubMichal Holub
Michal Holub
RJRobert Jankovych
Robert Jankovych
OAOndrej Andrs
Ondrej Andrs
ZKZdenek Kolibal
Zdenek Kolibal

8 September 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Michal HolubMichal Holub
Michal Holub
RJRóbert Jankových
Róbert Jankových
JVJan Vetiska
Jan Vetiska
JSJan Sramek
Jan Sramek
PBPetr Blecha
Petr Blecha
PHPetr Heinrich
Petr Heinrich
Currently, various types of software compensations are applied to machine tools. Their aim is to increase the working accuracy of the tools. The improvement in working accuracy is then further assessed according to the increase in the dimensional and shape accuracy or the surface quality of the workpiece. This publication describes the effects of the volumetric accuracy of a machine tool on the working accuracy of a workpiece, where total roundness (RONt) is evaluated in multiple cuts. In the experiment, two test workpieces are manufactured on a three-axis milling machining centre. The first is made using a standard machine setup while the second with activated volumetric compensation. The LaserTRACER self-tracking laser interferometer is used to compensate for volumetric accuracy. In the second part, verification measurements are performed with a Ballbar, where roundness error is evaluated according to ISO 230-4. Then two test workpieces are machined, and, in the last part, measurement is performed on Talyrond 595S roundness measuring equipment. Finally, the results are analysed and the dependence between the volumetric accuracy, the circularity error of the machine and the working accuracy of the CNC machine tool is established, represented by the RONt of the workpiece. This paper presents new and unpublished relations between the volumetric accuracy of the machine tool and the RONt of the workpiece.

20 May 2024 in Machines
Verified
Journal Article
Open access
PDF file
MSMatej Sarvaš
Matej Sarvaš
Michal HolubMichal Holub
Michal Holub
TMTomas Marek
Tomas Marek
JPJan Prochazka
Jan Prochazka
FBFrantišek Bradáč
František Bradáč
PBPetr Blecha
Petr Blecha
The operating conditions of the production process significantly influence the resulting dimensional and form accuracy of the workpiece. The operating conditions include the position of the workpiece location, with internal and external heat sources influenced not only by the machine location but also by its operation. In addition, there are the cutting conditions and the feed rate requirements of CNC machine tools. These changes, such as workpiece position, feed rates, and machine heat load, are further reflected in the ability of the machine to run at the position required and interpolate within the given tolerances of circularity. For the accuracy and repeatability of positioning, the machine was set up according to ISO 230-2 and for the circular interpolation tests according to ISO 230-4. The obtained results show the importance of attention to the appropriate setting of the operating conditions of the production process, where the knowledge of the geometric accuracy of the CNC machine tool in its working space can systematically increase the manufacturing accuracy itself or be another tool suitable for predicting the dimensional and form accuracy of workpieces.

23 November 2024 in Machines
Verified
Journal Article
Open access
PDF file
VSVendula Samelova
Vendula Samelova
TMTomas Marek
Tomas Marek
AJAdam Jelinek
Adam Jelinek
RJRóbert Jankových
Róbert Jankových
KMKarla Maradova
Karla Maradova
Michal HolubMichal Holub
Michal Holub
In modern manufacturing, there is an increasing demand for reliable in-process measurement methods directly on large CNC machine tools, eliminating the need to transport workpieces to metrological laboratories. This study assesses the capability and applicability of an articulated arm coordinate measuring machine and a machine tool touch-trigger probe when measuring to a specified tolerance of 0.05 mm in a production environment. Experiments were conducted using the KOBA calibration standard and included measurements with and without applying the articulated arm coordinate measuring machine leapfrog method. The results were evaluated according to ISO 22514-7:2021 and ISO 14253-1:2017, which establish criteria for measurement system capability. The findings revealed that neither measurement system met the capability requirements of ISO 22514-7:2021, particularly due to unsatisfactory QMS and CMS values. However, under ISO 14253-1:2017, both systems were deemed conditionally suitable for verifying conformity to the specifications, with the articulated arm coordinate measuring machine showing lower applicability when using the leapfrog method. This research supports the idea that unreasonable demands for compliance with current standards may lead to questioning of the systems that previously met older standards. The study contributes to the ongoing discussion on integrating advanced metrological tools into the manufacturing process and underscores the need for careful evaluation to ensure the capability and reliability of measurement systems in industrial practice.

14 December 2016 in MM Science Journal
Verified
Journal Article
Closed access
Michal HolubMichal Holub
Michal Holub
PBPetr Blecha
Petr Blecha
FBFrantisek Bradac
Frantisek Bradac
TMTomas Marek
Tomas Marek
ZZZdenek Zak
Zdenek Zak

10 September 2015 in MM Science Journal
Verified
Journal Article
Closed access
Michal HolubMichal Holub
Michal Holub
PBPetr Blecha
Petr Blecha
FBFrantisek Bradac
Frantisek Bradac
RKRoman Kana
Roman Kana