Uneven foundation settlement is one of the common engineering problems in a collapsible loess area. In order to study the influence of uneven foundation settlement on the seismic performance of a structure, the incremental dynamic analysis (IDA) method is used to analyze the seismic vulnerability of the steel structure frame. The differences in the seismic response of the structure in relation to uneven foundation settlement are analyzed. The influences of uneven foundation settlement quantities and various areas of uneven settlement on the seismic response of the structure are discussed. On this basis, the relationship between ground motion intensity and structural failure probability is studied, by changing the magnitude of seismic acceleration peaks. Compared with the unsettled structure, the internal force redistribution of the structure caused by uneven foundation settlement is one of the causes of earthquake damage for some components. The uneven foundation settlement located at the corner of the plane of the structure is likely to cause more serious earthquake damage to the structure. Uneven settlement will cause an increase in storey drift. With the increase in settlement, the seismic damage of the superstructure will be aggravated.
21 June 2023 in Modelling and Simulation in Engineering
Corrosion causes reduction in cross-sectional area of reinforcement, deterioration of mechanical properties, and degradation of bonding properties between reinforced concrete, which are the most important factors leading to the degradation of structural service performance. In order to investigate the progressive collapse mechanism of a corroded reinforced concrete frame structure, the failure modes, characteristics of the vertical displacement, and load capacity are studied using the finite element method. Based on existing experimental research, the established model is verified, and the influence of different influencing factors on the progressive collapse mechanism is analyzed. The results show that the corrosion of the reinforcement affects the yield load, peak load, and ultimate load of the reinforced concrete substructure. As the corrosion rate increases, the tensile arch action shows a particularly severe deterioration. The variation of concrete strength and the height–span ratio affects the substructure’s load-bearing capacity much more significantly than the stirrup spacing.
The design innovation of high-strength steel frames paired with D-eccentric bracing exhibits remarkable resistance to plastic deformation during seismic events. This method strategically combines regular steel connections (with yield strengths below 345 MPa) and high-strength steel beams and columns (such as Q460 or Q690, with yield strengths over 460 MPa), effectively reducing cross-sectional sizes while preserving the elasticity of non-energy-dissipating members. This configuration results in substantial ductility and superior energy dissipation capabilities. The response modification factor (R) is vital for achieving both effective and economical seismic resilience, particularly in the development of efficient and cost-effective seismic designs. However, the 2016 edition of the Code for Seismic Design of Buildings (GB50011-2010) fails to incorporate the concept of R, opting instead to apply a uniform value to all structural systems. This oversight is fundamentally flawed, necessitating a comprehensive investigation into the R value specifically for the high-strength steel frame with a D-eccentric brace. This research primarily aims to improve structural performance design, provide guidance for future projects, and encourage the adoption of this advanced seismic performance structure in earthquake-prone areas. To achieve these objectives, a performance-based seismic design approach is employed. This method involves designing structures with varying numbers of stories (4, 8, and 12), different link lengths (900, 1000, and 1100 mm), and various steel strengths (Q460 and Q690). This study uses the Incremental Dynamic Analysis (IDA) method to determine the R values for each prototype. The derived performance coefficients act as crucial references for the development of future innovative structural designs. This research greatly enhances seismic design practices and facilitates the wider adoption of high-strength steel frames with D-eccentric braces due to their outstanding seismic performance.
Coupling beams are critical connecting components in coupled shear wall systems and core tube structures. At the same time, they play an important role when the structure is subjected to an earthquake. Plate-reinforced composite (PRC) coupling beams exhibit superior comprehensive performance in terms of bearing capacity, deformation performance, energy dissipation capacity, and construction efficiency. However, research on PRC coupling beams remains limited both domestically and internationally. To better describe the structural response of steel plate–concrete composite coupling beams, this study collected existing experimental data. The beams had a small span-to-depth ratio. The loading was cyclic. The study normalized the skeleton curves of each specimen. The span-to-depth ratio ranged from 0.9 to 2.5. The plate ratio ranged from 3% to 5%. For these beams, preliminary skeleton curve fitting equations are proposed. The equations are based on existing data. The equations apply to two types of composite coupling beams. One type uses a steel plate and ordinary concrete. The other type uses a steel plate and fiber concrete. These equations are derived using a trilinear model and linear fitting tools. Furthermore, restoring force models for steel plate–conventional concrete and steel plate–fiber concrete composite coupling beams with a small span-to-depth ratio are proposed. Comparative analysis shows that each model captures the hysteretic response of PRC coupling beams with acceptable accuracy in the elastic and decline phases, while the elastic–plastic stage is suitable only for trend prediction. It should be noted that the proposed models are preliminary engineering approximations primarily applicable within the following ranges: a span-to-depth ratio of 0.9~2.5, a plate ratio of 3~5%, concrete strength of C30~C50, a longitudinal reinforcement ratio of 0.86~2.23%, a stirrup ratio of 0.56~0.63%, and a steel plate thickness of 6~10 mm. For configurations significantly outside these ranges, additional experimental validation is required.
This study focuses on the seismic performance of complicated nodes in the ultra-limited steel structure under rare occurrence earthquakes. The Xi’an Urban Exhibition Center (Chang’an Cloud) is chosen as the engineering background, and the ANSYS (18.0) analysis software is employed. Based on the overall importance and the extent of post-damage impacts, the critical nodes are selected for structural design. The research aims to develop simplified and reliable structural forms that can withstand the most adverse conditions at both the overall nodes and local component levels. Stress distribution under the most unfavorable scenarios is calculated to achieve the seismic design objectives of the overall structure. The research results indicate that localized stress concentration areas can reach or exceed the yield strength of the steel, which enters the plastic phase. The Von Mises stresses in the remaining nodes are lower than the yield strength of the steel. The overall performance is excellent without significant plastic deformation. Thus, the design requirements for non-yielding performance under rare seismic events are met. The conclusions can provide reliable references for the critical structural techniques and seismic design of complicated nodes.
Mixed structures with lightweight steel added stories are particularly vulnerable to damage and failure at the joints during seismic events. To evaluate the secondary seismic behavior of the joints in lightweight steel added stories after seismic damage repair, a low-cycle load test was conducted in this study. Following the initial damage, carbon fiber-reinforced polymer (CFRP) was applied for reinforcement, along with epoxy resin for the repair of concrete cracks. The experimental analysis focused on the structural deformation, failure characteristics, and energy dissipation capacity in both the original and repaired joint states. On the basis of the experimental findings, finite element analysis was carried out to examine the influence of varying CFRP layer configurations on the seismic performance of the repaired joints. The results revealed a significant change in the damage pattern of the repaired specimen, shifting from secondary surface damage to significant concrete deterioration localized at the bottom of the column. The failure mechanism was characterized by the CFRP-induced tensile forces acting on the concrete at the column base, following considerable deformation at the beam’s end. When compared to the original joint, the repaired joints exhibited markedly improved performance, with a 33% increase in horizontal ultimate strength and an 85% increase in energy dissipation capacity at failure. Additionally, the rotation angle between the beams and columns was effectively controlled. Joints repaired with two layers of CFRP demonstrated superior performance in contrast to those with a single layer. However, once the repaired joints met the required strength, further increasing the number of CFRP layers had a minimal influence on the mechanical properties of the joints. The proposed CFRP-based seismic retrofit method, which accounts for the strength degradation of concrete in damaged joints due to earthquake-induced damage, has proven to be both feasible and straightforward, offering an easily implementable solution to improve the seismic behavior of structures.