This paper presents an investigation on the practicability and structural efficiency of prestressed carbon-fiber–reinforced polymer (CFRP) strips with a gradient anchorage in the framework of a bridge-strengthening application in Poland. The nonmechanical anchorage system avoids the installation of metallic bolts and plates, with the exception of a temporary support frame. Two 18.4-m-long large-scale prestressed concrete girders were produced following the drawings of the existing bridge construction. One girder served as a reference, and the second one was strengthened with two prestressed CFRP strips. In this case, the initial negative cambering was leveled out by a layer of dry shotcrete. CFRP strips with a prestrain of 0.58% were applied for flexural upgrading. Both girders with a total length of 18.4 m were finally statically loaded up to failure to assess the strengthening efficiency in flexure of the retrofitting technique used. Tensile failure of the CFRP strips was reached, indicating an...
1 December 2014 in Advances in Structural Engineering
This paper presents recent experimental investigations on structural strengthening by means of (Carbon) Fiber Reinforced Cementitious Matrix (FRCM) in Switzerland. A first test series deals with full-scale reinforced concrete slabs strengthened with one or two composite reinforcement meshes embedded in a shotcrete layer. Static load tests up to failure show the efficiency of the strengthening in terms of increased yield and ultimate load compared to the reference specimen. Due to the initially necessary straightening of the textile, the contribution at lower deflection levels is limited. Only with advanced cracking and crack opening, the mesh develops its full contribution. Ultimate load is reached after a prompt relative slip of the mesh in the shotcrete. In the post-peak domain, failure by concrete crushing was observed. To study the residual tensile strength of the carbon reinforcement after exposure to high temperatures, various tensile tests on small rovings previously cut out of a composite mesh were performed. The specimens were heated to temperatures of 300 °C, 500 °C, 700 °C, and 1000 °C, kept at that level for 30 minutes, and finally cooled down to room temperature. The subsequent tensile tests performed at room temperature revealed a significant drop in the residual tensile strength for exposure temperature higher than 300 °C. A final test was performed on a reinforced concrete slab strip strengthened with a shotcrete layer including a composite mesh as tensile reinforcement. Under a constant service load, the slab was exposed to fire with a temperature rise according to a European standard curve (ETK) for two hours. The slab could withstand the applied loads for the full two hours, during which the composite mesh reached a temperature of about 440 °C. This observation is consistent with the results from tensile tests on filaments, clearly indicating a residual tensile strength after exposure at a similar temperature. The temperature in the internal steel reinforcement did not trespass a critical value of 500 °C as proposed by current design recommendations.
Advancements in optical imaging devices and computer vision algorithms allow the exploration of novel diagnostic techniques for use within engineering systems. A recent field of application lies in the adoption of such devices for non-contact vibrational response recordings of structures, allowing high spatial density measurements without the burden of heavy cabling associated with conventional technologies. This, however, is not a straightforward task due to the typically low-amplitude displacement response of structures under ambient operational conditions. A novel framework, namely Magnified Tracking (MT), is proposed herein to overcome this limitation through the synergistic use of two computer vision techniques. The recently proposed phase-based motion magnification (PBMM) framework, for amplifying motion in a video within a defined frequency band, is coupled with motion tracking by means of particle tracking velocimetry (PTV). An experimental campaign was conducted to validate a proof-of-concept, where the dynamic response of a shear frame was measured both by conventional sensors as well as a video camera setup, and cross-compared to prove the feasibility of the proposed non-contact approach. The methodology was explored both in 2D and 3D configurations, with PTV revealing a powerful tool for the measurement of perceptible motion. When MT is utilized for tracking “imperceptible” structural responses (i.e., below PTV sensitivity), via the use of PBMM around the resonant frequencies of the structure, the amplified motion reveals the operational deflection shapes, which are otherwise intractable. The modal results extracted from the magnified videos, using PTV, demonstrate MT to be a viable non-contact alternative for 3D modal identification with the benefit of a spatially dense measurement grid.
Externally Bonded Reinforcement (EBR) technique has been widely used for flexural strengthening of concrete structures by using carbon fiber-reinforced polymers (CFRP). EBR technique offers several structural advantages when the CFRP material is prestressed. This paper presents an experimental and numerical study on reinforced (RC) slabs strengthened in flexure with prestressed CFRP strips as a structural strengthening system. The strips are applied as an externally bonded reinforcement (EBR) and anchored with either a mechanical or a gradient anchorage. The former foresees metallic anchorage plates fixed to the concrete substrate, while the latter is based on an accelerated epoxy resin curing followed by a segment-wise prestress force decrease at the strip ends. Both anchorage systems, in combination with different CFRP strip geometries, were subjected to static loading tests. It could be demonstrated that the composite strip’s performance is better exploited when prestressing is used, with slightly higher overall load carrying capacities for mechanical anchorages than for the gradient anchorage. The performed investigations by means of a cross-section analysis supported the experimental observation that in case a mechanical anchorage is used, progressive strip debonding changes the fully bonded configuration to an unbonded end-anchored system. The inclusion of defined debonding criteria for both the anchorage zones and free length between the anchorage regions allowed to precisely capture the ultimate loading forces.
The long-term performance of externally-bonded reinforcements (EBR) on reinforced concrete (RC) structures highly depends on the behavior of constituent materials and their interfaces to various environmental loads, such as temperature and humidity exposure. Although significant efforts have been devoted to understanding the effect of such conditions on the anchorage resistance of unstressed EBR, with or without sustained loading, the effect of a released prestressing has not been thoroughly investigated. For this purpose, a series of experiments has been carried out herein, with concrete blocks strengthened with carbon fiber-reinforced polymer (CFRP) strips, both unstressed, as well as prestressed using the gradient anchorage. The gradient anchorage is a non-mechanical technique to anchor prestressed CFRP by exploiting the accelerated curing property of epoxy under higher temperatures and segment-wise prestress-force releasing. Subsequently, strengthened blocks are transferred into a chamber for exposure in dry freeze-thaw cycles (FTC). Following FTC exposure, the blocks are tested in a conventional lap-shear test setup to determine their residual anchorage resistance and then compared with reference specimens. Blocks were monitored during FTC by conventional and Fabry–Pérot-based fiber optic strain (FOS) sensors and a 3D-digital image correlation (3D-DIC) system during gradient application and lap-shear testing. Results indicate a reduction of residual anchorage resistance, stiffness and deformation capacity of the system after FTC and a change in the failure mode from concrete substrate to epoxy-concrete interface failure. It was further observed that all of these properties experienced a more significant reduction for prestressed specimens. These findings are presented with a complementary finite element model to shed more light onto the durability of such systems.