Masoud Motavalli

Prof. Dr. Masoud Motavalli

Structural Engineering Laboratory, Empa Swiss Federal Laboratories for Materials Science and Technology, Überlandstrasse 129, 8600 Dübendorf, Switzerland

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2011 in Journal of Composites for Construction
Verified
Journal Article
Closed access
Masoud MotavalliMasoud Motavalli
Masoud Motavalli
Christoph CzaderskiChristoph Czaderski
Christoph Czaderski
KPKerstin Pfyl-Lang
Kerstin Pfyl-Lang
In civil engineering today, only 20 to 30% of the strength of carbon-fiber-reinforced polymer (CFRP) strips is used when they are applied as externally bonded strips for flexural and shear strengthening or in confinement of reinforced concrete (RC) structural elements. The strips are better used when the CFRP material is prestressed. This offers several advantages, including reduced crack widths, reduced deflections, reduced stress in the internal steel, and possibly increased fatigue resistance. In this paper, recent developments in the field of RC strengthening using prestressed CFRP are presented. The paper focuses on developments in flexural and shear strengthening and column confinement made at the Swiss Federal Laboratory for Materials Testing and Research (Empa). Several innovative ideas have been successfully realized in the laboratory. For example, a gradient prestressing technique without end anchorage plates was developed and successfully applied to a 17 m RC bridge girder. A confinement techni...

1 October 2013 in Journal of Composites for Construction
Verified
Journal Article
Closed access
JMJulien Michels
Julien Michels
Jose Sena-CruzJose Sena-Cruz
Jose Sena-Cruz
Christoph CzaderskiChristoph Czaderski
Christoph Czaderski
Masoud MotavalliMasoud Motavalli
Masoud Motavalli
This paper presents the principle and the application of an innovative anchorage technique for prestressed carbon fiber–reinforced polymer (CFRP) strips in structural strengthening. Additionally, large-scale static loading tests of retrofitted concrete beams are shown. The gradient anchorage, based on the adhesive’s ability to undergo accelerated curing at high temperatures, consists of a purely concrete-adhesive strip connection without any mechanical devices, such as bolts or plates. In a first step, this study summarizes anchorage techniques presented in the literature and introduces the basic principles of the new method as well as the necessary components. In a second step, an application on a full-scale RC beam is explained in detail. A commercially-available CFRP strip is prestressed up to 0.6% prestrain and subsequently anchored by sequential epoxy-curing and force-releasing steps at both strip ends. Furthermore, uniaxial tensile tests on the epoxy adhesive and the CFRP strip are used for ...

1 August 2010 in Journal of Composites for Construction
Verified
Journal Article
Closed access
Christoph CzaderskiChristoph Czaderski
Christoph Czaderski
KSKhaled Soudki
Khaled Soudki
Masoud MotavalliMasoud Motavalli
Masoud Motavalli
Understanding the transfer of force by bond between externally bonded fiber-reinforced polymer (FRP) reinforcement and concrete is an important step in formulating good models for predicting debonding failures observed in externally bonded reinforcement strengthened systems. In this paper, a 3D optical displacement measurement system was used to capture the full-field displacements from the front and side view in pull-off bond specimens. The experiments were carried using six specimens with carbon FRP (CFRP) strips having different axial stiffnesses but a constant bond length to the concrete substrate. Using the optical measurements, it was possible to obtain the in-plane displacement or slip and the out-of-plane displacement or separation between the CFRP strip and the concrete. It was demonstrated, that the usual assumption of pure shear stresses in such pull-off tests is not true and that the bond behavior is a two-dimensional problem involving shear and peeling stresses. The bond behavior in CFRP stri...

6 January 2014 in Polymers
Verified
Journal Article
Open access
PDF file
JMJulien Michels
Julien Michels
Enzo MartinelliEnzo Martinelli
Enzo Martinelli
Christoph CzaderskiChristoph Czaderski
Christoph Czaderski
Masoud MotavalliMasoud Motavalli
Masoud Motavalli
This paper presents a study on the load carrying capacity of reinforced concrete (RC) beams strengthened with externally bonded (EB) carbon fiber reinforced polymer (CFRP) strips prestressed up to 0.6% in strain. At the strip ends, the innovative gradient anchorage is used instead of conventional mechanical fasteners. This method, based on the epoxy resin’s ability to rapidly cure under high temperatures, foresees a sector-wise heating followed by a gradual decrease of the initial prestress force towards the strip ends. The experimental investigation shows a promising structural behavior, resulting in high strip tensile strains, eventually almost reaching tensile failure of the composite strip. Additionally, ductility when considering deflection at steel yielding and at ultimate load is satisfying, too. From a practical point of view, it is demonstrated that premature strip grinding in the anchorage zone is not beneficial. In addition, a non-commercial 1D finite element code has been enlarged to an EB reinforcement with prestressed composite strips. A bilinear bond stress-slip relation obtained in earlier investigations is introduced as an additional failure criterion to the code. The numerical code is able to almost perfectly predict the overall structural behavior. Furthermore, the calculations are used for comparison purposes between an initially unstressed and a prestressed externally bonded composite reinforcement. The increase in cracking and yielding load, as well as differences in structural stiffness are apparent.

1 January 2007 in Journal of Structural Engineering
Verified
Journal Article
Closed access
DGDaniel Gsell
Daniel Gsell
GFGlauco Feltrin
Glauco Feltrin
SSSandy Schubert
Sandy Schubert
RSRene Steiger
Rene Steiger
Masoud MotavalliMasoud Motavalli
Masoud Motavalli
Cross-laminated solid wood panels are used in timber structures as load bearing plates and shear panels. Since timber is a relatively soft construction material, the design of such structures is driven by serviceability criteria. Therefore, accurate elastic properties are required. In this paper a fully automated procedure to determine global elastic properties of full-scale cross-laminated wood panels is developed. Experimental modal analysis is used to determine resonance frequencies and mode shapes of rectangular wooden specimens. An analytical model based on Reddy’s higher order plate theory is applied to calculate natural frequencies and mode shapes numerically. Corresponding frequencies are allocated using the modal assurance criterion. All three shear moduli and the two in-plane stiffness moduli are identified successfully by minimizing the difference between measured and estimated resonance frequencies in a total least squares sense. By comparing resonance frequencies and additionally by a static ...

1 May 2016 in Journal of Bridge Engineering
Verified
Journal Article
Open access
JMJulien Michels
Julien Michels
MSMichał Staśkiewicz
Michał Staśkiewicz
Christoph CzaderskiChristoph Czaderski
Christoph Czaderski
Renata KotyniaRenata Kotynia
Renata Kotynia
YHYunus Emre Harmanci
Yunus Emre Harmanci
Masoud MotavalliMasoud Motavalli
Masoud Motavalli
This paper presents an investigation on the practicability and structural efficiency of prestressed carbon-fiber–reinforced polymer (CFRP) strips with a gradient anchorage in the framework of a bridge-strengthening application in Poland. The nonmechanical anchorage system avoids the installation of metallic bolts and plates, with the exception of a temporary support frame. Two 18.4-m-long large-scale prestressed concrete girders were produced following the drawings of the existing bridge construction. One girder served as a reference, and the second one was strengthened with two prestressed CFRP strips. In this case, the initial negative cambering was leveled out by a layer of dry shotcrete. CFRP strips with a prestrain of 0.58% were applied for flexural upgrading. Both girders with a total length of 18.4 m were finally statically loaded up to failure to assess the strengthening efficiency in flexure of the retrofitting technique used. Tensile failure of the CFRP strips was reached, indicating an...