The COVID-19 pandemic has emphasized the importance and urgent need for rapid and accurate diagnostic tests for detecting and screening this infection. Our proposal was to develop a biosensor based on an ELISA immunoassay for monitoring antibodies against SARS-CoV-2 in human serum samples. The nucleocapsid protein (N protein) from SARS-CoV-2 was employed as a specific receptor for the detection of SARS-CoV-2 nucleocapsid immunoglobulin G. N protein was immobilized on the surface of a screen-printed carbon electrode (SPCE) modified with carboxylated graphene (CG). The percentage of IgG-SARS-CoV-2 nucleocapsid present was quantified using a secondary antibody labeled with horseradish peroxidase (HRP) (anti-IgG-HRP) catalyzed using 3,3′,5,5′-tetramethylbenzidine (TMB) mediator by chronoamperometry. A linear response was obtained in the range of 1:1000–1:200 v/v in phosphate buffer solution (PBS), and the detection limit calculated was 1:4947 v/v. The chronoamperometric method showed electrical signals directly proportional to antibody concentrations due to antigen-antibody (Ag-Ab) specific and stable binding reaction.
Biosensors harness biological materials as receptors linked to transducers, enabling the capture and transformation of primary biorecognition signals into measurable outputs. This study presents a novel carboxylation method for synthesizing carboxylated graphene (CG) under acidic conditions, enhancing biosensing capabilities. The characterization of the CG was performed using scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDS), Raman spectroscopy, thermogravimetric analysis (TGA), and X-ray diffraction (XRD). We modified screen-printed carbon electrodes (SPCEs) with CG to immobilize the SARS-CoV-2 N-protein, facilitating targeted detection of IgA antibodies (IgA-SARS-CoV-2). The analytical performance was assessed via electrochemical techniques such as cyclic voltammetry and electrochemical impedance spectroscopy, confirming CG synthesis effectiveness and biosensor functionality. The developed biosensor efficiently detects IgA-SARS-CoV-2 across a dilution range of 1:1000 to 1:200 v/v in a phosphate-buffered saline (PBS) solution, with a limit of detection calculated at 1:1601 v/v. This device shows considerable potential because of its fast response time, miniaturized design facilitated by SPCEs, reduced sample volume requirements, high sensitivity and specificity, low detection limits, and signal enhancement achieved through nanomaterial integration.
Electropolymerized poly(o-ethoxyaniline) (POEA) nanostructured thin films were successfully deposited on indium tin oxide (ITO) substrate. The surface dynamic of the films was extensively investigated using morphological and multifractal parameters extracted from the atomic force microscopy (AFM). AFM topographical maps reveal surfaces with different morphologies as a function of the deposition cycles. The height parameters show that there is greater spatial vertical growth for films deposited with higher cycles of deposition. After five cycles of deposition occurs the formation of a more isotropic surface, while for 15 cycles a less isotropic surface is observed. The Minkowski functionals confirm that morphological aspects of the two films change according to the amount of deposition cycles employed. The POEA surfaces also exhibit a strong multifractal nature with a decrease in the multifractal spectrum width as the number of deposition cycles increases. Our findings prove that deposition cycles can be useful in controlling the vertical growth and surface dynamics of electropolymerized POEA nanostructured samples, which can be useful for improving the fabrication of POEA-coated ITO-based devices.
TiO2 time-dependent electrodeposited thin films were synthesized using an electrophoretic apparatus. The XRD analysis revealed that the films could exhibit a crystalline structure composed of ~81% anatase and ~6% rutile after 10 s of deposition, with crystallite size of 15 nm. AFM 3D maps showed that the surfaces obtained between 2 and 10 s of deposition exhibit strong topographical irregularities with long-range and short-range correlations being observed in different surface regions, a trend also observed by the Minkowski functionals. The height-based ISO, as well as specific surface microtexture parameters, showed an overall decrease from 2 to 10 s of deposition, showing a subtle decrease in the vertical growth of the films. The surfaces were also mapped to have low spatial dominant frequencies, which is associated with the similar roughness profile of the films, despite the overall difference in vertical growth observed. The electrical conductivity measurements showed that despite the decrease in topographical roughness, the films acquired a thickness capable of making them increasingly insulating from 2 to 10 s of deposition. Thus, our results prove that the deposition time used during the electrophoretic experiment consistently affects the films’ structure, morphology, and electrical conductivity.
The effects on the structure and magnetic properties of Eu1−xYxMnO3 (0.0 ≤ x ≤ 0.5) thin films due to lattice strain were investigated and compared with those obtained in equivalent composition ceramics. The films were deposited by spin-coating chemical solution onto Pt\TiO2\SiO2\Si (100) standard substrates. X-ray diffraction and Raman spectroscopy measurements revealed that all films crystallize in orthorhombic structure with space group Pnma, observing an added contraction of the unit cell with increasing Y-substitution ou Eu, corresponding to a broadening of the Mn-O1-Mn angle and a gradual decrease in magnetic order response.