This study compares the compression force of cortical screws used in lag fashion with partially threaded cannulated screws and fully threaded headless cannulated screws as fixation methods for humeral condylar fractures in dogs. Cadavers of eleven dogs weighing an average of 10.99 ± 2.51 kg (6.1–14.4 kg) were used. The humeri were subjected to simulated fracture by performing an osteotomy at the trochlea of humerus and classified into three groups: Group 1 applied a 3.0 mm cortical screw applied in a lag fashion, Group 2 applied a 3.0 mm partially threaded cannulated screw, and Group 3 applied a 3.5 mm fully threaded headless cannulated screw. The samples were then placed in a material testing machine, and a compression force was applied vertically to the lateral condyle until failure. There were statistically significant differences in failure load between the groups (p = 0.009). The maximum failure load in Group 3 was significantly higher than in Group 2 (p = 0.014), while there were no statistically significant differences between Group 1 and Group 2) or between Group 1 and Group 3. Partially threaded cannulated screws and fully threaded headless cannulated screws can be alternatives to traditional stabilization methods, offering simpler procedures and additional advantages.
17 February 2026 in American Journal of Veterinary Research
Objective: To compare the biomechanical stability of 3 fixation techniques for unilateral sacroiliac (SI) luxation using 3-D–printed feline pelvic models. Methods: Eighteen 3-D–printed pelvic models were generated from CT data of a 6.6-kg cat. The study was conducted from July 25 through September 10, 2025. A right SI luxation with ipsilateral pubic and ischial osteotomies was created, and models were fabricated for 3 fixation configurations (n = 6/group): single lag screw with transiliac pinning (SP), double parallel Kirschner wires (DK), and double J-shaped Kirschner wires (DJ). A 3-D–printed femur was toggle pinned to the acetabulum to reproduce stance. Axial compression was applied to the femoral head at 5 mm/min to 15° pelvic rotation. Outcomes included rotational stiffness (primary), maximum load at 10° rotation, and energy absorption. Results: DJ constructs showed approximately 3-fold greater initial rotational stiffness and higher energy absorption than SP and DK. Mean maximum load to 10° rotation was 93.10 N for DJ versus 33.32 N (SP) and 36.59 N (DK). No differences were detected between SP and DK for any parameter. Conclusions: In this ex vivo 3-D–printed model, DJ fixation provided superior rotational stability compared with SP and DK techniques. Clinical Relevance: The DJ technique may offer a biomechanically robust alternative for stabilizing feline SI luxation. By avoiding the narrow sacral safe corridor required for lag screw placement, this method may reduce the risk of iatrogenic nerve injury while preserving sacral bone integrity to ensure optimal purchase and minimize the risk of fixation failure during stabilization.
1 June 2026 in American Journal of Veterinary Research
Objective: To biomechanically evaluate the efficacy of the lateral tripod 3-pin (3LTP) technique as an alternative to crosspinning (XP) for Kirschner wire internal fixation of distal femoral physeal fractures in small-breed canines. Methods: For this experimental biomechanical study (from February through October 2025), 30 polycarbonate 3-D–printed bone models simulating a Salter-Harris type I (SH-I) fracture were allocated equally (n = 10/group) to 3 fixation groups: the XP group, lateral double-pinning (2LP) group, and 3LTP group, all stabilized with 1.0-mm Kirschner wires. The maximum failure load (Newtons) was recorded as the primary outcome following an axial loading compression test on a universal testing machine until implant failure. Data were statistically analyzed. Results: A total of 30 models were included in the final analysis (n = 10/group). The mean maximum failure loads were determined to be 385.60 N (95% CI, 367.5 to 403.7) for XP, 330.70 N (95% CI, 311.4 to 350.0) for 2LP, and 445.10 N (95% CI, 412.4 to 477.8) for 3LTP. The failure mode for all groups was implant bending. Conclusions: The 3LTP demonstrated superior biomechanical resistance to axial compression compared to XP and 2LP for canine distal femoral SH-I fractures. Clinical Relevance: The utilization of the 3LTP technique offers a biomechanically superior and minimally invasive fixation alternative to XP for repairing canine distal femoral SH-I fractures.
Infiltrative lipomas involving the upper cervical spine present a significant surgical challenge, as the extensive muscular resection required for tumor control often leads to severe structural instability. This report describes the surgical treatment of an infiltrative lipoma that extensively invaded the cervical area in a 9-year-old dog. Following wide surgical debulking, a dual-plane stabilization strategy was employed. Ventral stabilization was attempted using standard C1–C2 transarticular screw fixation, while a modified dorsal stabilization technique anchored the occipital protuberance to the C2 spinous process using an ultra-high molecular weight polyethylene (UHMWPE) suture construct, combined with nuchal ligament reconstruction. Follow-up at 78 days revealed failure of the ventral implants, characterized by immediate improper positioning of the right screw and subsequent migration of the left screw. Despite these complications and confirmed tumor recurrence, the patient maintained normal neurological function and clinical cervical stability. This clinical course was suggestive of fibrous or early osseous union at the atlantoaxial joint. These findings suggest that the modified dorsal stabilization technique provided critical biomechanical support, effectively compensating for the compromised ventral fixation, and may represent a potential surgical option for managing extensive occipito-cervical instability in dogs.
Advanced periodontal disease can compromise the recipient tissues available for flap fixation during oronasal fistula repair. This report describes double-layer repair of an acquired periodontal oronasal fistula in an eight-year-old castrated male Beagle. Radiographs and computed tomography (CT) identified regional bone loss and residual alveolar bone adjacent to the defect. Following extraction of the left maxillary canine and second premolar and debridement of the fistula margins, an inverted hard palatal mucoperiosteal flap was anchored to residual buccal alveolar bone through four transosseous bone holes created with an 18-gauge needle. Transosseous suture fixation used 4-0 polydioxanone simple interrupted sutures. A buccal mucosal advancement flap covered the inverted flap and palatal donor site; no interpositional graft was used. Healing without clinically evident dehiscence was documented on postoperative day 18, and nasal discharge had resolved by day 45. At 555 days, visual oral examination revealed an intact repair, with concordant CT findings obtained for an unrelated otologic indication. This case illustrates the use of residual buccal alveolar bone for palatal flap attachment when periodontal tissue loss limits gingival recipient margins, with maintained closure documented at late clinical and imaging reassessment.