Objective: To compare the biomechanical stability of 3 fixation techniques for unilateral sacroiliac (SI) luxation using 3-D–printed feline pelvic models. Methods: Eighteen 3-D–printed pelvic models were generated from CT data of a 6.6-kg cat. The study was conducted from July 25 through September 10, 2025. A right SI luxation with ipsilateral pubic and ischial osteotomies was created, and models were fabricated for 3 fixation configurations (n = 6/group): single lag screw with transiliac pinning (SP), double parallel Kirschner wires (DK), and double J-shaped Kirschner wires (DJ). A 3-D–printed femur was toggle pinned to the acetabulum to reproduce stance. Axial compression was applied to the femoral head at 5 mm/min to 15° pelvic rotation. Outcomes included rotational stiffness (primary), maximum load at 10° rotation, and energy absorption. Results: DJ constructs showed approximately 3-fold greater initial rotational stiffness and higher energy absorption than SP and DK. Mean maximum load to 10° rotation was 93.10 N for DJ versus 33.32 N (SP) and 36.59 N (DK). No differences were detected between SP and DK for any parameter. Conclusions: In this ex vivo 3-D–printed model, DJ fixation provided superior rotational stability compared with SP and DK techniques. Clinical Relevance: The DJ technique may offer a biomechanically robust alternative for stabilizing feline SI luxation. By avoiding the narrow sacral safe corridor required for lag screw placement, this method may reduce the risk of iatrogenic nerve injury while preserving sacral bone integrity to ensure optimal purchase and minimize the risk of fixation failure during stabilization.
1 June 2026 in American Journal of Veterinary Research
Objective: To biomechanically evaluate the efficacy of the lateral tripod 3-pin (3LTP) technique as an alternative to crosspinning (XP) for Kirschner wire internal fixation of distal femoral physeal fractures in small-breed canines. Methods: For this experimental biomechanical study (from February through October 2025), 30 polycarbonate 3-D–printed bone models simulating a Salter-Harris type I (SH-I) fracture were allocated equally (n = 10/group) to 3 fixation groups: the XP group, lateral double-pinning (2LP) group, and 3LTP group, all stabilized with 1.0-mm Kirschner wires. The maximum failure load (Newtons) was recorded as the primary outcome following an axial loading compression test on a universal testing machine until implant failure. Data were statistically analyzed. Results: A total of 30 models were included in the final analysis (n = 10/group). The mean maximum failure loads were determined to be 385.60 N (95% CI, 367.5 to 403.7) for XP, 330.70 N (95% CI, 311.4 to 350.0) for 2LP, and 445.10 N (95% CI, 412.4 to 477.8) for 3LTP. The failure mode for all groups was implant bending. Conclusions: The 3LTP demonstrated superior biomechanical resistance to axial compression compared to XP and 2LP for canine distal femoral SH-I fractures. Clinical Relevance: The utilization of the 3LTP technique offers a biomechanically superior and minimally invasive fixation alternative to XP for repairing canine distal femoral SH-I fractures.