Objective: To compare the biomechanical stability of 3 fixation techniques for unilateral sacroiliac (SI) luxation using 3-D–printed feline pelvic models. Methods: Eighteen 3-D–printed pelvic models were generated from CT data of a 6.6-kg cat. The study was conducted from July 25 through September 10, 2025. A right SI luxation with ipsilateral pubic and ischial osteotomies was created, and models were fabricated for 3 fixation configurations (n = 6/group): single lag screw with transiliac pinning (SP), double parallel Kirschner wires (DK), and double J-shaped Kirschner wires (DJ). A 3-D–printed femur was toggle pinned to the acetabulum to reproduce stance. Axial compression was applied to the femoral head at 5 mm/min to 15° pelvic rotation. Outcomes included rotational stiffness (primary), maximum load at 10° rotation, and energy absorption. Results: DJ constructs showed approximately 3-fold greater initial rotational stiffness and higher energy absorption than SP and DK. Mean maximum load to 10° rotation was 93.10 N for DJ versus 33.32 N (SP) and 36.59 N (DK). No differences were detected between SP and DK for any parameter. Conclusions: In this ex vivo 3-D–printed model, DJ fixation provided superior rotational stability compared with SP and DK techniques. Clinical Relevance: The DJ technique may offer a biomechanically robust alternative for stabilizing feline SI luxation. By avoiding the narrow sacral safe corridor required for lag screw placement, this method may reduce the risk of iatrogenic nerve injury while preserving sacral bone integrity to ensure optimal purchase and minimize the risk of fixation failure during stabilization.
Canine mammary comedocarcinoma is considered an aggressive histological subtype with a high potential for metastatic dissemination. A 13-year-old intact female Jindo-mixed dog underwent mastectomy for a grade II mammary comedocarcinoma, and no metastatic involvement was identified in the regional lymph nodes or thorax at initial staging. On postoperative day (POD) 65, the dog developed an atraumatic pathological fracture of the left femoral diaphysis. Despite two surgical fixation procedures, the fracture progressed to non-union with progressive osteolysis. During subsequent follow-up, a subcutaneous mass and radiographic evidence of pulmonary metastasis were identified, and metastatic involvement of the femur was subsequently supported by histopathological examination. The dog died spontaneously on POD 188 following progressive disease and deterioration in clinical condition. Necropsy revealed extensive metastatic carcinoma involving the femur, medial iliac lymph node, lungs, and surrounding soft tissues. This case describes rapid and extensive multisystemic metastatic progression of canine mammary comedocarcinoma despite initially negative regional lymph node and thoracic staging. Notably, the atraumatic pathological femoral fracture was the first clinically recognized manifestation of metastatic disease. This case highlights the potential for skeletal involvement to cause substantial morbidity during metastatic progression of canine mammary carcinoma and emphasizes the importance of considering skeletal metastasis in dogs with aggressive mammary carcinoma presenting with unexplained pathological fractures or persistent failure of fracture healing.
1 June 2026 in American Journal of Veterinary Research
Objective: To biomechanically evaluate the efficacy of the lateral tripod 3-pin (3LTP) technique as an alternative to crosspinning (XP) for Kirschner wire internal fixation of distal femoral physeal fractures in small-breed canines. Methods: For this experimental biomechanical study (from February through October 2025), 30 polycarbonate 3-D–printed bone models simulating a Salter-Harris type I (SH-I) fracture were allocated equally (n = 10/group) to 3 fixation groups: the XP group, lateral double-pinning (2LP) group, and 3LTP group, all stabilized with 1.0-mm Kirschner wires. The maximum failure load (Newtons) was recorded as the primary outcome following an axial loading compression test on a universal testing machine until implant failure. Data were statistically analyzed. Results: A total of 30 models were included in the final analysis (n = 10/group). The mean maximum failure loads were determined to be 385.60 N (95% CI, 367.5 to 403.7) for XP, 330.70 N (95% CI, 311.4 to 350.0) for 2LP, and 445.10 N (95% CI, 412.4 to 477.8) for 3LTP. The failure mode for all groups was implant bending. Conclusions: The 3LTP demonstrated superior biomechanical resistance to axial compression compared to XP and 2LP for canine distal femoral SH-I fractures. Clinical Relevance: The utilization of the 3LTP technique offers a biomechanically superior and minimally invasive fixation alternative to XP for repairing canine distal femoral SH-I fractures.
A 10-year-old castrated male Chihuahua weighing 3.06 kg was presented with a chronic, progressively worsening cough of five months’ duration. Diagnostic imaging, including thoracic radiography and computed tomography, identified a well-defined cranial mediastinal mass consistent with a thymic tumor. Surgical excision was performed via median sternotomy with complete thymectomy. Following tumor removal, sternal closure was achieved using a non-absorbable ultra-high-molecular-weight polyethylene (UHMWPE) suture material (FiberWire®, Arthrex, Naples, FL, USA). Histopathological examination confirmed the diagnosis of an epithelial-predominant thymoma with narrow but complete surgical margins. Postoperative recovery was uneventful, and the dog was discharged three days after surgery. Clinical signs, including coughing, progressively improved during follow-up. Radiographic evaluation performed up to postoperative day 57 demonstrated stable sternal alignment without evidence of dehiscence, implant-related complications, or disease recurrence. This report describes the first clinical case of FiberWire use for median sternotomy closure following thymectomy in a dog. The favorable clinical and radiographic outcomes observed during postoperative follow-up suggest that FiberWire may represent a viable alternative to traditional stainless-steel wire for sternal fixation in canine thoracic surgery.
Infiltrative lipomas involving the upper cervical spine present a significant surgical challenge, as the extensive muscular resection required for tumor control often leads to severe structural instability. This report describes the surgical treatment of an infiltrative lipoma that extensively invaded the cervical area in a 9-year-old dog. Following wide surgical debulking, a dual-plane stabilization strategy was employed. Ventral stabilization was attempted using standard C1–C2 transarticular screw fixation, while a modified dorsal stabilization technique anchored the occipital protuberance to the C2 spinous process using an ultra-high molecular weight polyethylene (UHMWPE) suture construct, combined with nuchal ligament reconstruction. Follow-up at 78 days revealed failure of the ventral implants, characterized by immediate improper positioning of the right screw and subsequent migration of the left screw. Despite these complications and confirmed tumor recurrence, the patient maintained normal neurological function and clinical cervical stability. This clinical course was suggestive of fibrous or early osseous union at the atlantoaxial joint. These findings suggest that the modified dorsal stabilization technique provided critical biomechanical support, effectively compensating for the compromised ventral fixation, and may represent a potential surgical option for managing extensive occipito-cervical instability in dogs.
This report describes an atypical presentation of pyogranulomatous panniculitis and perifolliculitis in an 11-year-old mixed-breed dog. The patient presented with a firm, warm cervical mass that progressed with unusual aggression over a matter of days. While advanced diagnostics, including Computed Tomography (CT) and Ultrasonography (US), provided critical data regarding the lesion’s extent, they proved deceptive in determining its etiology; the imaging demonstrated apparent continuity between the mass and the adjacent musculature, strongly favoring a diagnosis of invasive neoplasia. Due to this diagnostic ambiguity and the mass’s rapid expansion, the lesion was surgically excised for definitive analysis. Surprisingly, histopathological examination contradicted the clinical and radiographic suspicion of malignancy, identifying instead a severe multifocal-to-coalescing inflammatory process. The patient recovered rapidly postoperatively with no evidence of recurrence. This case highlights that while imaging is an invaluable tool for surgical planning, it cannot reliably differentiate between aggressive inflammatory processes and invasive masses. The patient’s rapid recovery with no recurrence reinforces this limitation. Consequently, histopathological examination remains the gold standard for definitively diagnosing and guiding the management of rapidly expanding lesions.