Christopher Knowlton

Dr. Christopher Knowlton

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 March 2022 in Sensors
Verified
Journal Article
Open access
PDF file
LCLeora A. Cramer
Leora A. Cramer
Markus A. A WimmerMarkus A. A Wimmer
Markus A. A Wimmer
PMPhilip Malloy
Philip Malloy
JOJoan Ann O'Keefe
Joan Ann O'Keefe
CKChristopher Knowlton
Christopher Knowlton
CFChristopher Ferrigno
Christopher Ferrigno
Pressure-detecting insoles such as the Insole3 have potential as a portable alternative for assessing vertical ground reaction force (vGRF) outside of specialized laboratories. This study evaluated whether the Insole3 is a valid and reliable alternative to force plates for measuring vGRF. Eleven healthy participants walked overground at slow and moderately paced speeds and ran at a moderate pace while collecting vGRF simultaneously from a force plate (3000 Hz) and Insole3 (100 Hz). Intraclass correlation coefficients (ICC) demonstrated excellent vGRF agreement between systems during both walking speeds for Peak 1, Peak 2, the valley between peaks, and the vGRF impulse (ICC > 0.941). There was excellent agreement during running for the single vGRF peak (ICC = 0.942) and impulse (ICC = 0.940). The insoles slightly underestimated vGRF peaks (−3.7% to 0.9% bias) and valleys (−2.2% to −1.8% bias), and slightly overestimated impulses (4.2% to 5.6% bias). Reliability between visits for all three activities was excellent (ICC > 0.970). The Insole3 is a valid and reliable alternative to traditional force plates for assessing vGRF during walking and running in healthy adults. The excellent ICC values during slow walking suggests that the Insole3 may be particularly suitable for older adults in clinical and home settings.

1 August 2016 in Clinical Orthopaedics and Related Research
Verified
Journal Article
Closed access
RPRobin Pourzal
Robin Pourzal
CKChristopher Knowlton
Christopher Knowlton
DHDeborah J Hall
Deborah J Hall
MLMichel P. Laurent
Michel P. Laurent
RURobert M. Urban
Robert M. Urban
MWMarkus A. Wimmer
Markus A. Wimmer
Ll of interest for the knee, particularly because few studies have investigated volumetric material loss in tibial knee inserts. For this study, a unique collection of autopsy-retrieved TKR and THR components that were well-functioning at the time of retrieval was used to compare volumetric wear differences between hip and knee polyethylene components made from identical material. Questions/purposes The following questions were addressed: (1) How much did the hip liners wear and what wear patterns did they exhibit? (2) How much did the knee inserts wear and what wear patterns did they exhibit? (3) What is the ratio between TKR and THR wear after controlling for implantation time and patient age? Methods We compared 23 THR components (Harris-Galante [HG] and HG II) and 20 TKR components (Miller-Galante [MG II]) that were retrieved postmortem. The components were made from the same polyethylene formulation and with similar manufacturing and sterilization (gamma-in-air) processes. Twenty-one patients (12 males, nine females) had THRs and 16 (four males, 12 females) had TKRs. Patients who had TKRs had an older (p = 0.001) average age than patients who had THRs (age, 75 years; SD, 10, versus 66 years; SD, 12, respectively). Only well-functioning components were included in this study. Therefore, implants retrieved postmortem from physically active patients and implanted for at least 2 years were considered. In addition, only normally wearing TKR components were considered, ie, those with fatigue wear (delamination) were excluded. The wear volume of each component was measured using metrology. For the tibial inserts an autonomous mathematic reconstruction method was used for quantification. Results The acetabular liners of the THR group had a wear rate of 38 mm3 per year (95% CI, 29-47 mm3/year). Excluding patients with low-activity, the wear rate was 47 mm3 per year (95% CI, 37-56 mm3/year). The wear rate of normally wearing tibial inserts was 17 mm3 per year (95% CI, −6 to 40 mm3/year). After controlling for the relevant confounding variable of age, we found a TKR/THR wear rate ratio of 0.5 (95% CI, 0.29-0.77) at 70 years of age with a slightly increasing difference with increasing age. Conclusions Excluding delamination, TKRs exhibited lower articular wear rates than THRs for historical polyethylene in these two unique cohorts of postmortem retrievals. Clinical Relevance The lower TKR wear rate is in line with the lower incidence of osteolysis in TKRs compared with THRs....

12 July 2016 in Journal of Biomedical Materials Research Part B: Applied Biomaterials
Verified
Journal Article
Closed access
PDF file
CKChristopher Knowlton
Christopher Knowlton
PBPriyanka Bhutani
Priyanka Bhutani
Markus A. A WimmerMarkus A. A Wimmer
Markus A. A Wimmer

1 February 2013 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
HLHannah J. Lundberg
Hannah J. Lundberg
CKChristopher Knowlton
Christopher Knowlton
MWMarkus A. Wimmer
Markus A. Wimmer
The purpose of this study was to perform a blinded comparison of model predictions of total knee replacement contact forces to in vivo forces from an instrumented prosthesis during normal walking and medial thrust gait by participating in the “Third Grand Challenge Competition to Predict in vivo Knee Loads.” We also evaluated model assumptions that were critical for accurate force predictions. Medial, lateral, and total axial forces through the knee were calculated using a previously developed and validated parametric numerical model. The model uses equilibrium equations between internal and external moments and forces to obtain knee joint contact forces and calculates a range of forces at instances during the gait cycle through parametric variation of muscle activity levels. For 100 instances during a normal over-ground gait cycle, model root mean square differences from eTibia data were 292, 248, and 281 for medial, lateral, and total contact forces, respectively. For 100 instances during a medial thrust gait cycle, model root mean square differences from eTibia data were 332, 234, and 470 for medial, lateral, and total contact forces, respectively. The percent difference between measured and predicted peak total axial force was 2.89% at the first peak and 9.36% at the second peak contact force for normal walking and 3.94% at the first peak and 14.86% at the second peak contact force for medial thrust gait. After unblinding, changes to model assumptions improved medial and lateral force predictions for both gait styles but did not improve total force predictions. Axial forces computed with the model compared well to the eTibia data under blinded and unblinded conditions. Knowledge of detailed knee kinematics, namely anterior-posterior translation, appears to be critical in obtaining accurate force predictions.

22 August 2012 in Journal of Biomedical Materials Research Part B: Applied Biomaterials
Verified
Journal Article
Closed access
PDF file
CKChristopher Knowlton
Christopher Knowlton
Markus A. A WimmerMarkus A. A Wimmer
Markus A. A Wimmer

1 July 2017 in The Journal of Arthroplasty
Verified
Journal Article
Closed access
RFRyan D. Freed
Ryan D. Freed
JSJacqueline C. Simon
Jacqueline C. Simon
CKChristopher Knowlton
Christopher Knowlton
DVDiego A. Orozco Villaseñor
Diego A. Orozco Villaseñor
MWMarkus A. Wimmer
Markus A. Wimmer
HLHannah J. Lundberg
Hannah J. Lundberg