Structural health monitoring is vital for the safety and longevity of infrastructure, particularly in seismic zones. This study focuses on identifying the dynamic properties of a reinforced concrete building in Chile’s Valparaíso region. Using an experimental approach, the study compares ambient vibration records, seismic events (moment magnitude > 4), and data collected during adjacent construction activities. Force-balanced accelerometers were used for vibration measurements. The analysis employs the Stochastic Subspace Identification with Covariances (SSI-COV) method within an operational modal analysis framework to extract the building’s modal parameters without requiring artificial excitations. This technique effectively identifies modal characteristics under different vibration sources, making it suitable for evaluating the structural condition under diverse loading conditions. The findings reveal the building’s modes and frequencies, offering critical insights for maintenance and management of infrastructure. Little to no variations were observed in the identified frequencies of the building when working with different types of input data. These data support the integration of real-time IoT systems for continuous monitoring, providing a foundation for future digital twin applications. These advancements facilitate early deterioration detection, enhancing resilience in seismic environments.
Municipal bridge management requires accessible monitoring approaches that provide objective information on vibration activity under operational conditions. This study develops and evaluates a low-cost cyber–physical sensing architecture using the Lusitania Bridge in Viña del Mar, Chile, as a case study. The system integrates four ESP32/MPU9250 sensing nodes, cascade Wi-Fi/WebSocket forwarding, a Raspberry Pi 4 gateway with an auxiliary local MPU9250 channel, and structured post-processing. Its contribution is the author-developed system-level integration and bounded field evaluation rather than the novelty of the individual components. In the laboratory shaker test, each remote node occupied 13,560 of 15,001 bins on a fixed 100 Hz grid, corresponding to a 9.61% temporal-continuity deficit; the stored-row rate was 100.023 Hz. Cross-correlation signal lags were within one to two nominal sampling intervals, but these lags are not treated as pure clock-synchronization errors. The field campaign comprised 19 short sessions collected during one experimental day. The mean session-level fixed-grid deficit was 21.04%, with values ranging from 6.83% to 44.09%, showing that end-to-end continuity was the principal operational constraint. Session S18 had the lowest deficit, 6.83%, and 214 valid 30 s windows out of 271 candidates. In S18, a higher-vibration interval showed 0.5–20 Hz band-limited RMS ratios of 1.91–2.86 and band-power increases of 5.6–9.1 dB relative to a low-activity interval. Because the sensors were mounted on the railing and no calibrated reference accelerometer was available, the results support short-duration vibration-activity monitoring and system testing, not global modal identification, damage diagnosis, warning capability, or long-term SHM.