Evgeny Lian

Dr. Evgeny Lian


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2022 in Circulation: Arrhythmia and Electrophysiology
Verified
Journal Article
Open access
PDF file
Christian-H HeegerChristian-H Heeger
Christian-H Heeger
CSChristian Sohns
Christian Sohns
APAlexander Pott
Alexander Pott
AMAndreas Metzner
Andreas Metzner
OIOsamu Inaba
Osamu Inaba
RTRoland Richard Tilz
Roland Richard Tilz
Background: Cryoballoon-based pulmonary vein isolation (PVI) has emerged as an effective treatment for atrial fibrillation. The most frequent complication during cryoballoon-based PVI is phrenic nerve injury (PNI). However, data on PNI are scarce. Methods: The YETI registry is a retrospective, multicenter, and multinational registry evaluating the incidence, characteristics, prognostic factors for PNI recovery and follow-up data of patients with PNI during cryoballoon-based PVI. Experienced electrophysiological centers were invited to participate. All patients with PNI during CB2 or third (CB3) and fourth-generation cryoballoon (CB4)-based PVI were eligible. Results: A total of 17 356 patients underwent cryoballoon-based PVI in 33 centers from 10 countries. A total of 731 (4.2%) patients experienced PNI. The mean time to PNI was 127.7±50.4 seconds, and the mean temperature at the time of PNI was −49±8°C. At the end of the procedure, PNI recovered in 394/731 patients (53.9%). Recovery of PNI at 12 months of follow-up was found in 97.0% of patients (682/703, with 28 patients lost to follow-up). A total of 16/703 (2.3%) reported symptomatic PNI. Only 0.06% of the overall population showed symptomatic and permanent PNI. Prognostic factors improving PNI recovery are immediate stop at PNI by double-stop technique and utilization of a bonus-freeze protocol. Age, cryoballoon temperature at PNI, and compound motor action potential amplitude loss >30% were identified as factors decreasing PNI recovery. Based on these parameters, a score was calculated. The YETI score has a numerical value that will directly represent the probability of a specific patient of recovering from PNI within 12 months. Conclusions: The incidence of PNI during cryoballoon-based PVI was 4.2%. Overall 97% of PNI recovered within 12 months. Symptomatic and permanent PNI is exceedingly rare in patients after cryoballoon-based PVI. The YETI score estimates the prognosis after iatrogenic cryoballoon-derived PNI. Registration: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT03645577. Graphic A graphic abstract is available for this article.

20 July 2023 in EP Europace
Verified
Journal Article
Open access
PDF file
ZSZdenek Starek
Zdenek Starek
Andrea Di CoriAndrea Di Cori
Andrea Di Cori
TBTimothy Betts
Timothy Betts
GCGael Clerici
Gael Clerici
DGDaniel Gras
Daniel Gras
PSPhilipp Sommer
Philipp Sommer
Electro-anatomical mapping may be critical to identify atrial fibrillation (AF) subjects who require substrate modification beyond pulmonary vein isolation (PVI). The objective was to determine correlations between pre-ablation mapping characteristics and 12-month outcomes after a single PVI-only catheter ablation of AF. This study enrolled paroxysmal AF (PAF), early persistent AF (PsAF; 7 days–3 months), and non-early PsAF (>3–12 months) subjects undergoing de novo PVI-only radiofrequency catheter ablation. Sinus rhythm (SR) and AF voltage maps were created with the Advisor HD Grid™ Mapping Catheter, Sensor Enabled™ for each subject, and the presence of low-voltage area (LVA) (low-voltage cutoffs: 0.1–1.5 mV) was investigated. Follow-up visits were at 3, 6, and 12 months, with a 24-h Holter monitor at 12 months. A Cox proportional hazards model identified associations between mapping data and 12-month recurrence after a single PVI procedure. The study enrolled 300 subjects (113 PAF, 86 early PsAF, and 101 non-early PsAF) at 18 centres. At 12 months, 75.5% of subjects were free from AF/atrial flutter (AFL)/atrial tachycardia (AT) recurrence. Univariate analysis found that arrhythmia recurrence did not correlate with AF diagnosis, but LVA was significantly correlated. Low-voltage area (28% of the left atrium in SR [hazard ratio (HR): 4.82, 95% confidence interval (CI): 2.08–11.18; P = 0.0003] and >72% in AF (HR: 5.66, 95% CI: 2.34–13.69; P = 0.0001) was associated with a higher risk of AF/AFL/AT recurrence at 12 months. Larger extension of LVA was associated with an increased risk of arrhythmia recurrence. These subjects may benefit from substrate modification beyond PVI.

22 April 2024 in EP Europace
Verified
Journal Article
Open access
PDF file
RTRoland Richard Tilz
Roland Richard Tilz
MFMarcel Feher
Marcel Feher
JVJulia Vogler
Julia Vogler
KBKerstin Bode
Kerstin Bode
ADAlexandru Ionut Duta
Alexandru Ionut Duta
SPSorin Stefan Popescu
Sorin Stefan Popescu
Aims: Simplified ablation technologies for pulmonary vein isolation (PVI) are increasingly performed worldwide. One of the most common complications following PVI are vascular access-related complications. Lately, venous closure systems (VCSs) were introduced into clinical practice, aiming to reduce the time of bed rest, to increase the patients’ comfort, and to reduce vascular access-related complications. The aim of the present study is to compare the safety and efficacy of using a VCS to achieve haemostasis following single-shot PVI to the actual standard of care [figure-of-eight suture and manual compression (MC)]. Methods and results: This is a prospective, multicentre, randomized, controlled, open-label trial performed at three German centres. Patients were randomized 1:1 to undergo haemostasis either by means of VCS (VCS group) or of a figure-of-eight suture and MC (F8 group). The primary efficacy endpoint was the time to ambulation, while the primary safety endpoint was the incidence of major periprocedural adverse events until hospital discharge. A total of 125 patients were randomized. The baseline characteristics were similar between the groups. The VCS group showed a shorter time to ambulation [109.0 (82.0, 160.0) vs. 269.0 (243.8, 340.5) min; P < 0.001], shorter time to haemostasis [1 (1, 2) vs. 5 (2, 10) min; P < 0.001], and shorter time to discharge eligibility [270 (270, 270) vs. 340 (300, 458) min; P < 0.001]. No major vascular access-related complication was reported in either group. A trend towards a lower incidence of minor vascular access-related complications on the day of procedure was observed in the VCS group [7 (11.1%) vs. 15 (24.2%); P = 0.063] as compared to the control group. Conclusion: Following AF ablation, the use of a VCS results in a significantly shorter time to ambulation, time to haemostasis, and time to discharge eligibility. No major vascular access-related complications were identified. The use of MC and a figure-of-eight suture showed a trend towards a higher incidence of minor vascular access-related complications.

22 March 2018 in Pacing and Clinical Electrophysiology
Verified
Journal Article
Closed access
PDF file
ELEvgeny Lian
Evgeny Lian
ATAlexey Tsyganov
Alexey Tsyganov
AAAyan Abdrahmanov
Ayan Abdrahmanov
AMAlexander Morozov
Alexander Morozov
ABAbay Bakytzhanuly
Abay Bakytzhanuly
NSNoureddin Sawan
Noureddin Sawan

27 September 2024 in EP Europace
Verified
Journal Article
Open access
PDF file
PFPiotr Futyma
Piotr Futyma
ASArian Sultan
Arian Sultan
ŁZŁukasz Piotr Zarębski
Łukasz Piotr Zarębski
DIDr. Med. Guram Imnadze
Dr. Med. Guram Imnadze
VMVera Maslova
Vera Maslova
JCJulian K R Chun
Julian K R Chun
Advanced ablation strategies are needed to treat ventricular tachycardia (VT) and premature ventricular complexes (PVC) refractory to standard unipolar radiofrequency ablation (Uni-RFA). Bipolar radiofrequency catheter ablation (Bi-RFA) has emerged as a treatment option for refractory VT and PVC. Multicentre registry data on the use of Bi-RFA in the setting of refractory VT and PVC are lacking. The aim of this Bi-RFA registry is to determine its real-world safety, feasibility, and efficacy in patients with refractory VT/PVC. Consecutive patients undergoing Bi-RFA at 16 European centres for recurring VT/PVC after at least one standard Uni-RFA were included. Second ablation catheter was used instead of a dispersive patch and was positioned at the opposite site of the ablation target. Between March 2021 and August 2024, 91 patients underwent 94 Bi-RFA procedures (74 males, age 62 ± 13, and prior Uni-RFA range 1–8). Indications were recurrence of PVC (n = 56), VT (n = 20), electrical storm (n = 13), or PVC-triggered ventricular fibrillation (n = 2). Procedural time was 160 ± 73 min, Bi-RFA time 426 ± 286 s, and mean Uni-RFA time 819 ± 697 s. Elimination of clinical VT/PVC was achieved in 67 (74%) patients and suppression of VT/PVC in a further 10 (11%) patients. In the remaining 14 patients (15%), no effect on VT/PVC was observed. Three major complications occurred: coronary artery occlusion, atrioventricular block, and arteriovenous fistula. Follow-up lasted 7 ± 8 months. Nineteen patients (61%) remained VT free. ≥80% PVC burden reduction was achieved in 45 (78%). These real-world registry data indicate that Bi-RFA appears safe, is feasible, and is effective in the majority of patients with VT/PVC.

1 July 2017 in Heart Rhythm
Verified
Journal Article
Closed access
ELEvgeny Lian
Evgeny Lian
MTMauro Toniolo
Mauro Toniolo
ATAlexey Tsyganov
Alexey Tsyganov
LRLuca Rebellato
Luca Rebellato
APAlessandro Proclemer
Alessandro Proclemer
MYMarina Yakovleva
Marina Yakovleva