Changzhao Pan

Dr. Changzhao Pan


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 October 2020 in Metrologia
Verified
Journal Article
Open access
PDF file
BGBo Gao
Bo Gao
HZHaiyang Zhang
Haiyang Zhang
DHDongxu Han
Dongxu Han
CPChangzhao Pan
Changzhao Pan
HCHui Chen
Hui Chen
LPLaurent Pitre
Laurent Pitre
We describe measurements of thermodynamic temperature in the range 5 K to 24.5561 K (the triple point of neon) using single-pressure refractive-index gas thermometry (SPRIGT) with 4He. In the wake of the May 2019 re-definition of the kelvin and its associated mise en pratique, the main purpose of the work is to provide values of T–T 90, the discrepancy between thermodynamic temperature and that of the International Temperature Scale of 1990 (ITS-90). The link to ITS-90 is made via calibrated rhodium-iron resistance thermometers. Innovations required to reach the level of accuracy required for meaningful measurements (uncertainty in T–T 90 less than the expected deviation) include the suppression of temperature oscillations in a cryogen-free cryostat, a pressure stabilization scheme based on a non-rotating piston balance, modelling of the hydrostatic head correction and refinements of the measurement of microwave resonances in a quasi-spherical copper resonator. The accuracy of measurements varies from 0.05 mK to 0.17 mK and is competitive with that of all previous ones in this temperature range using other techniques. The improvement stems partly from the new techniques used for the new definition of the kelvin as well as ab initio calculations of the thermophysical properties ofgaseous 4He. In addition to confirming the validity of SPRIGT as an accurate, easier-to-implement alternative to other low-temperature primary thermometry techniques (e.g. acoustic gas thermometry) yet with scope for improvement, the results should provide important input data for any future revision of ITS-90.

1 October 2014 in Computers & Chemical Engineering
Verified
Journal Article
Closed access
CPChangzhao Pan
Changzhao Pan
YZYuan Zhou
Yuan Zhou
JWJunjie Wang
Junjie Wang

1 April 2018 in International Journal of Refrigeration
Verified
Journal Article
Closed access
CLChen Liubiao
Chen Liubiao
WXWu Xianlin
Wu Xianlin
LXLiu Xuming
Liu Xuming
CPChangzhao Pan
Changzhao Pan
ZYZhou Yuan
Zhou Yuan
WJWang Junjie
Wang Junjie

1 July 2018 in International Journal of Thermal Sciences
Verified
Journal Article
Closed access
CPChangzhao Pan
Changzhao Pan
TZTong Zhang
Tong Zhang
JWJunjie Wang
Junjie Wang
YZYuan Zhou
Yuan Zhou

9 July 2021 in Metrologia
Verified
Journal Article
Open access
CPChangzhao Pan
Changzhao Pan
FSFernando Sparasci
Fernando Sparasci
HZHaiyang Zhang
Haiyang Zhang
PGPascal Gambette
Pascal Gambette
MPMark Plimmer
Mark Plimmer
LPLaurent Pitre
Laurent Pitre
We used absolute primary acoustic gas thermometry (AGT) to calibrate a Pt–Co resistance thermometer on the thermodynamic temperature scale by measuring the speed of sound in helium at a temperature T* chosen to be near the temperature of the triple point of neon, T Ne. Prior to the present AGT, the Pt–Co thermometer was used with a neon triple-point cell as part of an interlaboratory comparison. Taken together, the results of the interlaboratory comparison and the present AGT redetermined the thermodynamic temperature T Ne = (24.555 15 ± 0.000 24) K. This new value of T Ne is consistent with other recent determinations obtained with various primary methods. After completing the AGT thermodynamic calibration, we used the Pt–Co thermometer to link T* to the temperature ratios measured by single-pressure refractive-index gas thermometry (SPRIGT) in a different laboratory. (Gao et al 2020 Metrologia 57 065006) Now, the T*-linked SPRIGT system can calibrate other thermometers on the thermodynamic temperature scale T in the range 5 K ⩽ T ⩽ T Ne without using the international temperature scale ITS-90. At most temperatures in this range, the uncertainties of the T*-linked SPRIGT system are smaller than those of the ITS-90 systems used by National Metrology Institutes to calibrate resistance thermometers.

1 July 2016 in Cryogenics
Verified
Journal Article
Closed access
CPChangzhao Pan
Changzhao Pan
TZTong Zhang
Tong Zhang
YZYuan Zhou
Yuan Zhou
JWJunjie Wang
Junjie Wang