This paper introduces a new technique for the distributed voltage and frequency control of the local ac-grid in offshore wind farms based on synchronous generators. The proposed control technique allows the connection of the offshore wind farm using a diode based HVdc rectifier. The use of microgrid control techniques allowed the system comprising the wind farm and the diode HVdc rectifier to be operated in current or voltage control mode. Fault response to on-shore voltage sags of up to 80% has been shown to be comparable to that of thyristor rectifiers. The proposed control technique has been shown to be robust against load changes in islanded operation, capacitor bank switching, diode-rectifier ac-breaker tripping and wind turbine power limitation due to slow wind speeds. PSCAD simulations are used to prove the technical feasibility of the proposed control techniques both in steady state and during transients.
17 March 2011 in IEEE Transactions on Energy Conversion
This paper includes a technical feasibility study on the use of diode-based HVdc links for the connection of large offshore wind farms based on synchronous generators. A technique for the voltage and frequency control of the offshore ac grid is presented. The proposed control technique allows the operation of the rectifier end of the HVdc link in current or voltage control mode. Fault response to onshore voltage sags of up to 80% has been shown to be comparable to that of thyristor-based rectifiers. Moreover, the complete system shows an adequate fault-ride-through operation to solid short circuits at onshore inverter terminals. PSCAD ® simulations are used to prove the technical feasibility of the proposed control techniques both in steady state and during transients.
Energy storage has become a fundamental component in renewable energy systems, especially those including batteries. However, in charging and discharging processes, some of the parameters are not controlled by the battery’s user. That uncontrolled working leads to aging of the batteries and a reduction of their life cycle. Therefore, it causes an early replacement. Development of control methods seeks battery protection and a longer life expectancy, thus the constant-current–constant-voltage method is mostly used. However, several studies show that charging time can be reduced by using fuzzy logic control or model predictive control. Another benefit is temperature control. This paper reviews the existing control methods used to control charging and discharging processes, focusing on their impacts on battery life. Classical and modern methods are studied together in order to find the best approach to real systems.
Diagnosis of intermittent failures is relevant for productive processes which sustain a high level of maintenance caused by failures. Systems including electrical contacts suffer a considerable amount of intermittent failures which are usually not diagnosed. A characterization of the failure dynamics may save unnecessary repairs, and enable a better planning component substitution. This paper presents a new concept in failure diagnosis, the modeling of intermittent failure dynamics. It develops two methodologies for modeling intermittent failure dynamics, and generating information for maintenance scheduling.
A feasibility study for the installation of Wave Energy Converters (WEC) in a Spanish Mediterranean port is evaluated in this paper. The final aim is to evaluate the possibility of building a new infrastructure which combines a breakwater and a WEC able to provide energy to the commercial port of Valencia. An estimation of the wave power potential is made according to existing databases from different sources. A review of the existing WEC types is carried out in order to choose the most suitable technology for its installation in a port environment. The authors discuss the main advantages and issues of the integration of WEC in port breakwaters. A prospective study for the Port of Valencia is made, considering the port energy demand evolution, historical data on wave energy potential and the port expansion plans. We conclude that Overtopping Devices (OTDs) are the most suitable ones to allow the good integration with the new breakwater needed for the expansion of the Port of Valencia and we give an estimation on the power available from the resource in our case study.
Brain–computer interfaces (BCI) can extract information about the subject’s intentions by registering and processing electroencephalographic (EEG) signals to generate actions on physical systems. Steady-state visual-evoked potentials (SSVEP) are produced when the subject stares at flashing visual stimuli. By means of spectral analysis and by measuring the signal-to-noise ratio (SNR) of its harmonic contents, the observed stimulus can be identified. Stimulus color matters, and some authors have proposed red because of its ability to capture attention, while others refuse it because it might induce epileptic seizures. Green has also been proposed and it is claimed that white may generate the best signals. Regarding frequency, middle frequencies are claimed to produce the best SNR, although high frequencies have not been thoroughly studied, and might be advantageous due to the lower spontaneous cerebral activity in this frequency band. Here, we show white, red, and green stimuli, at three frequencies: 5 (low), 12 (middle), and 30 (high) Hz to 42 subjects, and compare them in order to find which one can produce the best SNR. We aim to know if the response to white is as strong as the one to red, and also if the response to high frequency is as strong as the one triggered by lower frequencies. Attention has been measured with the Conner’s Continuous Performance Task version 2 (CPT-II) task, in order to search for a potential relationship between attentional capacity and the SNR previously obtained. An analysis of variance (ANOVA) shows the best SNR with the middle frequency, followed by the low, and finally the high one. White gives as good an SNR as red at 12 Hz and so does green at 5 Hz, with no differences at 30 Hz. These results suggest that middle frequencies are preferable and that using the red color can be avoided. Correlation analysis also show a correlation between attention and the SNR at low frequency, so suggesting that for the low frequencies, more attentional capacity leads to better results.