Surface plasmon resonance (SPR) with two-dimensional (2D) materials is proposed to enhance the sensitivity of sensors. A novel Goos–Hänchen (GH) shift sensing scheme based on blue phosphorene (BlueP)/transition metal dichalogenides (TMDCs) and graphene structure is proposed. The significantly enhanced GH shift is obtained by optimizing the layers of BlueP/TMDCs and graphene. The maximum GH shift of the hybrid structure of Ag-Indium tin oxide (ITO)-BlueP/WS2–graphene is −2361λ with BlueP/WS2 four layers and a graphene monolayer. Furthermore, the GH shift can be positive or negative depending on the layer number of BlueP/TMDCs and graphene. For sensing performance, the highest sensitivity of 2.767 × 107λ/RIU is realized, which is 5152.7 times higher than the traditional Ag-SPR structure, 2470.5 times of Ag-ITO, 2159.2 times of Ag-ITO-BlueP/WS2, and 688.9 times of Ag-ITO–graphene. Therefore, such configuration with GH shift can be used in various chemical, biomedical and optical sensing fields.
In order to improve the performance of surface plasmon resonance (SPR) biosensor, the structure based on two-dimensional (2D) of graphene and transition metal dichalcogenides (TMDCs) are proposed to greatly enhance the Goos-Hänchen (GH) shift. It is theoretically proved that GH shift can be significantly enhanced in SPR structure coated with gold (Au)-indium tin oxide (ITO)-TMDCs-graphene heterostructure. In order to realize high GH shifts, the number of TMDCs and graphene layer are optimized. The highest GH shift (−801.7 λ) is obtained by Au-ITO-MoSe2-graphene hybrid structure with MoSe2 monolayer and graphene bilayer, respectively. By analyzing the GH variation, the index sensitivity of such configuration can reach as high as 8.02 × 105 λ/RIU, which is 293.24 times of the Au-ITO structure and 177.43 times of the Au-ITO-graphene structure. The proposed SPR biosensor can be widely used in the precision metrology and optical sensing.
Due to the large number of waterborne bacteria presenting in drinking water, their rapid and accurate identification has become a global priority. The surface plasmon resonance (SPR) biosensor with prism (BK7)-silver(Ag)-MXene(Ti3T2Cx)-graphene- affinity-sensing medium is examined in this paper, in which the sensing medium includes pure water, vibrio cholera (V. cholera), and escherichia coli (E. coli). For the Ag-affinity-sensing medium, the maximum sensitivity is obtained by E. coli, followed by V. cholera, and the minimum is pure water. Based on the fixed-parameter scanning (FPS) method, the highest sensitivity is 246.2 °/RIU by the MXene and graphene with monolayer, and with E. coli sensing medium. Therefore, the algorithm of improved differential evolution (IDE) is obtained. By the IDE algorithm, after three iterations, the maximum fitness value (sensitivity) of the SPR biosensor achieves 246.6 °/RIU by using the structure of Ag (61 nm)-MXene (monolayer)-graphene (monolayer)-affinity (4 nm)-E. coli. Compared with the FPS and differential evolution (DE) algorithm, the highest sensitivity is more accurate and efficient, and with fewer iterations. The performance optimization of multilayer SPR biosensors provides an efficient platform.
A surface plasmon resonance (SPR) sensor based on blue phosphorus (BlueP)/transition metal dichalcogenides (TMDCs) of two-dimensional (2D) materials is proposed to increase the performance. In this sensor, BlueP/TMDCs are coated on indium tin oxide (ITO) and different metals (Au/Ag/Cu) to improve the sensitivity. By optimizing structural parameters, with the monolayer and Au thin film, the angular sensitivity can reach as high as 226.0°/RIU. The phase sensitivity also can be as high as with 4 layers, 228 nm ITO, and 25 nm Au thin film, which is 6.77 times that of the Au-ITO structure and 54.40 times that of the traditional SPR of Au thin film. The SPR sensor has potential applications in disease diagnosis, drug development, gene sequencing and treatment, environmental monitoring, food safety testing, doping testing, and other fields.
The Goos-Hanchen (GH) shift caused by blue phosphorene/transition metal dichalcogenides (BlueP/TMDCs) and graphene surface plasma resonance (SPR) in Kretschmann configuration are studied theoretically. In this structure, graphene and BlueP/TMDCs coated on Cu thin film are optimized to improve the GH shift. The highest GH shift of sensor Cu-BlueP/WS2-graphene is 1004 lambda with three layers BlueP/WS2 and a graphene monolayer. For the sensing application, the sensitivity corresponding to the optimal GH shift is 3.199 x 10(6) lambda/RIU, which is 210.8 times higher than the traditional Cu film, 181.4 times higher than the Cu-BlueP/WS2 (monolayer) structure, and 56.6 times higher than the Cu-graphene structure. Therefore, the SPR sensor with high GH shift can be extensively used in the fields of chemical, biomedical, and environmental monitoring. (C) 2020 Optical Society of America