This review summarizes the application of two-dimensional metal–organic framework (2D MOF) nanostructures and their composites in the detoxification of chemical warfare agents (CWAs). Two-dimensional MOFs, characterized by their high specific surface area, abundant active sites, and structural tunability, exhibit promising catalytic performance in CWA detoxification. Various preparation methods, including top–down exfoliation and bottom–up assembly, are discussed for the synthesis of 2D MOF nanosheets. The catalytic performance of 2D MOFs and their composites in detoxifying CWAs is evaluated, highlighting their advantages in terms of reaction kinetics and ease of recycling. Additionally, the advances and challenges in this field are discussed, aiming to promote further research into and development of 2D MOF-based materials for CWA detoxification.
The 2D Cu2O@NC catalyst obtained by thermal decomposition of MOF, could effectively enhance the propofol removal from wastewater by activating peroxymonosulfate in the advanced oxidation process.
20 September 2021 in Journal of Nonlinear Mathematical Physics
By constructing a new calculating rule of Lie bracket, we construct a new nonlinear Schrödinger hierarchy and its reduction equations via using the \({\bar{\partial }}\)-method. Furthermore, some soliton solutions of such the equation are obtained by making use of Dirac function.
Chemical warfare agents (CWAs) refer to toxic chemical substances used in warfare. Recently, CWAs have been a critical threat for public safety due to their high toxicity. Metal–organic frameworks have exhibited great potential in protecting against CWAs due to their high crystallinity, stable structure, large specific surface area, high porosity, and adjustable structure. However, the metal clusters of most reported MOFs might be highly consumed when applied in CWA hydrolysis. Herein, we fabricated a two-dimensional piezoresponsive UiO-66-F4 and subjected it to CWA simulant dimethyl-4-nitrophenyl phosphate (DMNP) detoxification under sonic conditions. The results show that sonication can effectively enhance the removal performance under optimal conditions; the reaction rate constant k was upgraded 45% by sonication. Moreover, the first-principle calculation revealed that the band gap could be further widened with the application of mechanical stress, which was beneficial for the generation of 1O2, thus further upgrading the detoxification performance toward DMNP. This work demonstrated that mechanical vibration could be introduced to CWA protection, but promising applications are rarely reported.
The rapid detection of organophosphorus (OP) compounds is crucial for safeguarding human health and ensuring food safety. This study presents a novel wearable electrochemical biosensor that integrates miniaturized screen-printed electrodes with wearable devices to achieve real-time, on-site OP detection. The biosensor was fabricated by constructing a screen-printed carbon electrode (SPCE) on a thermoplastic polyurethane (TPU) substrate, sequentially modified with graphene (GR), gold nanoparticles (AuNPs), and organophosphorus hydrolase (OPH), and finally encapsulated with Nafion. This SPCE/GR/AuNPs/OPH/Nafion configuration yields a highly flexible and portable device. The detection principle relies on the enzymatic hydrolysis of methyl paraoxon (MPOX) by OPH, generating p-nitrophenol (PNP), which is quantitatively measured via square wave voltammetry (SWV). The sensor exhibits a broad linear detection range (30–400 μM) with a strong linear correlation (R2 = 0.995) and a low detection limit (0.321 μM). It demonstrates excellent selectivity against common interfering substances, including urea, sucrose, and various metal ions. Application to real-world samples such as cabbage and tap water yielded high recoveries (107.2% for cabbage and 101.2% for tap water), with relative standard deviations (RSDs) below 8%. Furthermore, the biosensor maintains robust flexibility and mechanical resilience, with less than 5% signal loss after 100 bending cycles, confirming its suitability for wearable applications and reliable operation under mechanical stress. This innovative, flexible electrochemical biosensor provides a powerful and reliable platform for rapid OP detection, particularly in complex testing environments.