Tadeusz Maciołek

Tadeusz Maciołek

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 March 2021 in Vehicle System Dynamics
Verified
Journal Article
Open access
AWAndrzej Wilk
Andrzej Wilk
Len GelmanLen Gelman
Len Gelman
SJSlawomir Judek
Slawomir Judek
KKKrzysztof Karwowski
Krzysztof Karwowski
MMMirosław Mizan
Mirosław Mizan
KKKarolina Klimowska
Karolina Klimowska
An increase in electric railway vehicles service velocity requires that correct interaction between the pantograph and the catenary is ensured. This implies the need for developing mathematical models of pantographs and catenaries and determining their parameters. The article presents a method to determine parameters of mechanical joints of a railway pantograph based on analysis of pantograph subassemblies in swinging motion. The experimental tests consisted in disassembling the pantograph and creating partial subassemblies which were then analysed with respect to their damped linear or angular oscillations. The simulation analysis required developing, in CAD, 3D models of individual pantograph parts and their subassemblies. Defined were joints between particular elements, which represent of real pantograph structure. The inertia parameters of the model were determined, based on structural characteristics and physical properties of materials, used for manufacturing individual pantograph elements, and then verified experimentally. The dissipative parameters of the mechanical joints were calculated iteratively. The model of complete pantograph assembly was also subject to verification and in this case, good convergence between simulation and experiment results was achieved. The obtained parameter values can be used in simulation models of other railway pantographs having a similar structure.

7 April 2022 in IEEE Transactions on Transportation Electrification
Verified
Journal Article
Closed access
MSMarcin Steczek
Marcin Steczek
WJWłodzimierz Jefimowski
Włodzimierz Jefimowski
TMTadeusz Maciołek
Tadeusz Maciołek
SBSławomir Barański
Sławomir Barański
The traction substation in conventional power supply systems for trams is a bottleneck of the system. It requires the connection with medium-voltage grid, demands high values of instant power and its centralized topology generates additional energy losses. Since the availability of low-power photovoltaic (PV) generation is increasing in the utility system, we propose to replace conventional substations with a distributed system of low-power devices cooperating with low-voltage grid and PV installations owned by individual households. The proposed in this article distributed power supply system for trams (DPSS-T) consists of multiple traction aggregators (TAs) equipped with energy storage devices (ESDs) which are distributed along the tram line. In order to evaluate the benefits of applying DPSS-T this proposed system was compared with the conventional topology regarding the energy losses in terms of annual operation. Moreover, the following aspects have been studied for the wide range EDS sizes and PV generation: PV energy injection into the power utility system, the utilization of installed ESD, and the contribution of PV generation in energy consumed by traction vehicles. At the same time, the energy management for this new topology has been proposed. The ESDs are charged with relatively low power, between tram runs and discharged with full power during the runs. The suggested energy management eliminates peaks in substation power demand. The obtained results show that despite the fact that the proposed DPSS-T is supplied from low-voltage grid the energy losses are reduced by 58%–69%.

25 April 2025 in Electronics
Verified
Journal Article
Open access
PDF file
Adam SzelągAdam Szeląg
Adam Szeląg
WJWłodzimierz Jefimowski
Włodzimierz Jefimowski
TMTadeusz Maciołek
Tadeusz Maciołek
Anatolii NikitenkoAnatolii Nikitenko
Anatolii Nikitenko
MWMaciej Wieczorek
Maciej Wieczorek
MLMirosław Lewandowski
Mirosław Lewandowski
This paper proposes the sizing optimization method and energy management strategy for a stationary hybrid energy storage system dedicated to a DC traction power supply system. The hybrid energy storage system consists of two modules—a supercapacitor, mainly dedicated to regenerative energy utilization, and a Li-ion battery, aimed to peak power reduction. The sizing method and energy management strategy proposed in this paper aim to reduce the aging effect of lithium-ion batteries. It is shown that the parameters of both modules could be sized independently. The supercapacitor module parameters are sized based on the results of a simulation determining the regenerative power, resulting in limited catenary receptivity. The simulation model of the DC electrification system is validated by comparing the results of the simulation with the measurements of 15 min average power in a 24 h cycle as average values of one year. The battery module is sized based on the statistical data of 15 min substation power value occurrences. The battery energy capacity, its maximum discharge C-rate, and the conditions determining its operation are optimized to achieve the maximum ratio of annual income resulting from peak power reduction to annual operating cost resulting from the battery aging process and total life cycle. The case study prepared for a typical 3 kV DC substation with mixed railway traffic shows that peak power could be reduced by ~1 MW, giving a ~10-year payback period for battery module installation, while the energy consumption could be decreased by 1.9 MWh/24 h, giving a ~7.5-year payback period for supercapacitor module installation. The payback period of the whole energy storage system (ESS) is ~8.4 years.

3 January 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
Adam SzelągAdam Szeląg
Adam Szeląg
WJWłodzimierz Jefimowski
Włodzimierz Jefimowski
TMTadeusz Maciołek
Tadeusz Maciołek
Anatolii NikitenkoAnatolii Nikitenko
Anatolii Nikitenko
MWMaciej Wieczorek
Maciej Wieczorek
MLMirosław Lewandowski
Mirosław Lewandowski
This paper proposes the sizing optimization method and energy management strategy for stationary hybrid energy storage system dedicated to DC power supply system. The hybrid energy storage consists of two modules – supercapacitor, mainly dedicated to regenerative energy utilization and electrochemical battery, aimed to peak power reduction. It is shown that the parameters of both modules could be sized independently. The supercapacitor module parameters are sized, based on the results of simulation determining the regenerative power, resulting limited catenary receptivity. The simulation model of DC electrification system is validated by comparing the results of simulation with the measurements of 15-min average power in 24-hour cycle as an average values of one year. The battery module is sized based on the statistical data of 15-min substation power values occurrences. The battery energy capacity, its maximum discharge C-rate and the conditions determining its operation are optimized to achieve the maximum ratio of annual income resulting from peak power reduction to annual operating cost resulting from battery aging process and total life cycle. The case study prepared for typical 3 kV DC substation with mixed railway traffic shows that peak power could be reduced by ~ 1 MW, giving ~ 10 years of payback period of battery module installation, while the energy consumption could be decreased by 1.9 MWh/24 h, giving the payback period of supercapacitor module installation ~ 7.5 years. The payback period of the whole energy storage system (ESS) is ~ 8.4 years.

29 June 2015 in ACTA IMEKO
Verified
Journal Article
Closed access
PDF file
Adam SzelągAdam Szeląg
Adam Szeląg
TMTadeusz Maciołek
Tadeusz Maciołek
MPMarek Patoka
Marek Patoka
Electric energy quality criteria relating to a DC supply system concern the circuits from the rectifiers installed in traction substations till the vehicle's current collector. Energy Law and related implementing provisions unequivocally state that an electrified transport system as the energy recipient shall fulfil the requirements regarding energy consumption, which are defined in the agreement. It imposes certain requirements for the railway power supply company. Introduction into traffic of the traction vehicles that are equipped with converter power electronics drive systems increased requirements regarding voltage quality in a DC catenary. At the same time, increase in share of non-linear recipients causes the increase of distortion in AC voltage supplying traction substations, and they also transfer to the DC side. Both these factors caused a change in operational conditions of the resonance smoothing filters hitherto used in rectifier traction substations supplied by AC medium voltage power lines. This paper presents a research and a case study of the problem of effectiveness of functioning of the used filters, from measurements allowing for problem identification to results of the studies of the proposed new solution of a filter and the results of observed exploitation of a prototype with the application of digital monitoring and diagnostics system.

16 May 2025 in Bulletin Of The Polish Academy Of Sciences-Technical Sciences
Verified
Journal Article
Open access
MLMirosław Lewandowski
Mirosław Lewandowski
MOMarek Orzydłowski
Marek Orzydłowski
TMTadeusz Maciołek
Tadeusz Maciołek
The supercapacitor supports the main energy source of the hybrid electrical energy storage system. In short periods, it supplies additional energy or absorbs braking energy. The paper addresses the issue of energy losses in supercapacitors used in such a pulsed mode of operation. Commonly used first-order RC capacitor impedance models are not a good basis for accurate calculation results of energy losses in supercapacitors. The article presents fractional-order supercapacitor impedance models based on the Cole-Cole relaxation equation. The following part presents the results of measurements of energy losses in real supercapacitors in comparison with simulation calculations using both above-mentioned supercapacitor impedance models. The article also discusses the problem of using the equivalent series resistance (ESR) values in RC impedance models, called AC ESR and DC ESR, specified by different supercapacitor manufacturers. It shows that the simulation results using the presented fractional impedance model are the closest to reality. The use of the other discussed models leads to even a several-fold underestimation of energy losses in supercapacitors used in electric energy storage systems.