The paper presents the results of economic study of energy storage system (ESS) implemented in 3 kV DC power supply system. Two conceptions of ESS have been investigated: ESS with supercapacitor (SC) and hybrid ESS (HESS) with SC and LFP battery. The investigated locations of energy storage systems are considered among existing traction substations in two railway lines with different density of train operation. The considered aims of energy storage system implementation are decreasing of energy consumption by maximum regenerative energy utilization and reduction of peak 15- min power demand of traction substation. The paper presents a method of regenerative power estimation depending on the location of the considered ESS implementation point. Also the method of optimal location selection of ESS in terms of minimization of Simple Payback Time (SPBT) of investment is presented. Besides the influence of initial cost value as well as energy price on the SPBT value are investigated. The results are compared between two railway lines with different number of trains operating.
In railway traction, the definition of “electromagnetic field” is functionally connected to the concept of the reactive power consumed by the electric rolling stock, and characterized by the running and standing electromagnetic waves in the space of the inter-substation zones from the site of the AC traction system. Such a definition is established and theoretically justified by the theory of electromagnetic fields. This article uses the methodology of this theory, in particular, a method for power balance estimation in electromagnetic fields based on Maxwell’s equations, as well as methods for the analysis of running and standing electromagnetic waves based on the theory of reflection, propagation and transmission of plane harmonic waves. The research considers the regularities of standing electromagnetic waves in the space of inter-substation zones of electric traction systems, which occur due to the incomplete reflection of incident waves from the contact wire and metal parts of the roof surface and the frontal part of the body of the electric rolling stock. The flow of electricity to the roof surface and the frontal part of the body of an electric locomotive is considered. The possibility of using existing methods to reduce wave reflections and thereby to effectively compensate for reactive power in the space of inter-substation zones is discussed.
This article presents a new method for the estimation of active power losses based on a “field” approach, i.e., on the theory of the electromagnetic field and the theory of propagation of electromagnetic waves in a dielectric medium. Electromagnetic waves are assumed to transmit energy from the traction substation to electric rolling stock through the airspace of the inter-substation zone (i.e., not through the wires of the traction network) and meet electrically conductive surfaces on their way. The waves are partially reflected from the surfaces and partially penetrate them, thus creating thermal losses, the determination of which is the main task of this article. The analytical expressions for specific losses of active power are obtained by solving the system of Maxwell’s equations. Calculations of specific power losses in the catenary, rails, roofs, and bottoms of carriages and electric locomotives are performed. Power losses in carriages and electric locomotives are found to be at least 7%. A comparative assessment of the magnitude of total power losses of different types obtained by the “field” and “circuit” approaches is provided, which has established that “conditional” losses correspond to losses in rails, train carriages, and electric locomotives.
This paper proposes the sizing optimization method and energy management strategy for a stationary hybrid energy storage system dedicated to a DC traction power supply system. The hybrid energy storage system consists of two modules—a supercapacitor, mainly dedicated to regenerative energy utilization, and a Li-ion battery, aimed to peak power reduction. The sizing method and energy management strategy proposed in this paper aim to reduce the aging effect of lithium-ion batteries. It is shown that the parameters of both modules could be sized independently. The supercapacitor module parameters are sized based on the results of a simulation determining the regenerative power, resulting in limited catenary receptivity. The simulation model of the DC electrification system is validated by comparing the results of the simulation with the measurements of 15 min average power in a 24 h cycle as average values of one year. The battery module is sized based on the statistical data of 15 min substation power value occurrences. The battery energy capacity, its maximum discharge C-rate, and the conditions determining its operation are optimized to achieve the maximum ratio of annual income resulting from peak power reduction to annual operating cost resulting from the battery aging process and total life cycle. The case study prepared for a typical 3 kV DC substation with mixed railway traffic shows that peak power could be reduced by ~1 MW, giving a ~10-year payback period for battery module installation, while the energy consumption could be decreased by 1.9 MWh/24 h, giving a ~7.5-year payback period for supercapacitor module installation. The payback period of the whole energy storage system (ESS) is ~8.4 years.
Purpose. Development and theoretical ground of the analytical method for the calculation of the active, reactive and total powers in the electric traction devices, taking into consideration the non-stationary character of the stochastic processes change of the voltage and current in the elements of these systems. Methodology. The mathematical methods of the random processes theory and the “discrete electrical engineering” methods are used for solving the main problem of this paper. Findings. The Method of the Correlation and Dispersion is developed for definition of the active power, the reactive power by Fryse and the total power of the devices in the elements of the electric traction system of the main-line railways. The method is based on the well-known concepts of auto- and inter-correlation functions of the random processes which govern the feeder voltages and the currents in the traction power supply subsystem as well as the currents and voltages of the electric rolling stock. The method developed in this paper allows estimating the powers of both stationary and non-stationary processes. This method can be used for the analysis of both the traction mode and the regenerative braking mode of the electric rolling stock. The total power components were calculated for the one of the feeder areas of the Prydniprovsk railway using this method. The results show the significant flow of the reactive power in the traction power supply system. This fact is also confirmed by the high values of the reactive power coefficient. Originality. Scientific novelty of the research is consisted in the following. Firstly, for defining the active and reactive powers in elements of the traction power supply system the new method (the Method of Correlation and Dispersion) is created and grounded. This method is different from other existing methods because it takes into consideration the varying non-stationary character of the chance processes of the feeder and substation voltages and currents. Secondly, in the DC traction power supply system the large values of the exchange reactive power by Fryze were created for the first time. Practical value.The method and its technique allow calculating the main energy coefficients for the traction power systems such are the reactive power coefficient, the main and additional active power losses in the power circuit of the electric rolling stockand the traction power supply system.