Sarah Zeriouh

Sarah Zeriouh

Auto-generated profile, based on publicly available information

Sarah Zeriouh

Department of Cardiology, Royal Papworth Hospital NHS Foundation Trust, Cambridge, UK

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 December 2023 in EP Europace
Verified
Journal Article
Open access
PDF file
DRDomenico Giovanni. Della Rocca
Domenico Giovanni. Della Rocca
LMLorenzo Marcon
Lorenzo Marcon
MMMichele Magnocavallo
Michele Magnocavallo
Roberto MenèRoberto Menè
Roberto Menè
LPLuigi Pannone
Luigi Pannone
MMMark La Meir
Mark La Meir
Pulsed field ablation (PFA) has emerged as a novel, non-thermal energy source to selectively ablate cardiac tissue. We describe a multicentre experience on pulmonary vein isolation (PVI) via the pentaspline Farapulse™ PFA system vs. thermal-based technologies in a propensity score-matched population of paroxysmal atrial fibrillation (PAF) patients. Propensity score matching was adopted to compare PVI-only ablation outcomes via the Farawave™ system (Group PFA), cryoballoon (Group CRYO), or focal radiofrequency (Group RF) (PFA:CRYO:RF ratio = 1:2:2). Among 1572 (mean age: 62.4 ± 11.3 years; 42.5% females) PAF patients undergoing first time PVI with either PFA (n = 174), CRYO (n = 655), or RF (n = 743), propensity score matching yielded 174 PFA, 348 CRYO, and 348 RF patients. First-pass isolation was achieved in 98.8% of pulmonary veins (PVs) with PFA, 81.5% with CRYO, and 73.1% with RF (P < 0.001). Procedural and dwell times were significantly shorter with PFA, whereas the availability of a 3D mapping system led to a significant reduction in X-ray exposure with RF. Overall complication rates were 3.4% (n = 6) with PFA, 8.6% (n = 30) with CRYO, and 5.5% (n = 19) with RF (P = 0.052). The 1-year Kaplan–Meier estimated freedom from any atrial tachyarrhythmia was 79.3% with PFA, 74.7% with CRYO, and 72.4% with RF (log-rank P-value: 0.24). Among 145 repeat ablation procedures, PV reconnection rate was 19.1% after PFA, 27.5% after CRYO, and 34.8% after RF (P = 0.01). Pulsed field ablation contributed to significantly shorter procedural times. Follow-up data showed a similar arrhythmia freedom, although a higher rate of PV reconnection was documented in post-CRYO and post-RF redo procedures.

1 January 2024 in Circulation: Arrhythmia and Electrophysiology
Verified
Journal Article
Open access
Roberto MenèRoberto Menè
Roberto Menè
SBSerge Boveda
Serge Boveda
DRDomenico Giovanni. Della Rocca
Domenico Giovanni. Della Rocca
VSVasileios Sousonis
Vasileios Sousonis
GVGiampaolo Vetta
Giampaolo Vetta
SCStéphane Combes
Stéphane Combes

18 December 2024 in Open Heart
Verified
Journal Article
Open access
PDF file
MMMark T Mills
Mark T Mills
STSaket Trivedi
Saket Trivedi
MLMatthew J Lovell
Matthew J Lovell
FMFrancis Murgatroyd
Francis Murgatroyd
PCPeter Calvert
Peter Calvert
DTDerick M Todd
Derick M Todd
Introduction: Pulsed-field ablation (PFA) is a novel modality for pulmonary vein isolation in patients with atrial fibrillation (AF). We describe the initial uptake and experience of PFA using a pentaspline catheter across selected National Health Service England (NHSE) centres. Methods: Data collected by NHSE Specialised Services Development Programme regarding AF ablation procedures using a single-shot, pentaspline, multielectrode PFA catheter (FARAWAVE, Boston Scientific) between June 2022 and August 2024 were aggregated and analysed to examine procedural metrics, acute efficacy and safety outcomes over 3-month follow-up. Results: 1034 procedures were submitted. The patients were 32.1% female, mean age 63.8±10.7 years, 53.1% paroxysmal AF and 89.7% first-time AF ablation. Procedures were performed by 48 consultant operators at nine NHSE centres, with a mean of 115 procedures per centre (range 25–264). 93.7% of procedures were performed under general anaesthesia. Median skin-to-skin procedure time was 74 min (IQR 55–96 min) and fluoroscopy time 20 min (IQR 15–27 min). Electroanatomical mapping was used in 15.3%. In first-time ablation cases, acute isolation of all pulmonary veins was achieved in 99.5% of patients. Left atrial (LA) posterior wall ablation using the PFA catheter was performed in 11.0% of cases; additional LA radiofrequency ablation was performed in 0.6%. The major and minor acute procedural complication rates were, respectively, 1.3% and 3.1%, with no reports of periprocedural death or atrio-oesophageal fistula. 63.8% of patients were discharged on the day of procedure. Follow-up data were available for 870 procedures (84.1%). In the 3 months following ablation, hospitalisation for arrhythmia occurred in 3.2%, with 0.9% rehospitalised for procedural-related complications. Conclusion: In this real-world, nationwide registry of a pentaspline PFA catheter, efficacy, safety and efficiency outcomes were comparable to those from previous PFA studies in patients with AF.

5 March 2024 in Archives of Cardiovascular Diseases
Verified
Journal Article
Closed access
CCCorentin Chaumont
Corentin Chaumont
EMEmily McDonnell
Emily McDonnell
SBSerge Boveda
Serge Boveda
ASArnaud Savoure
Arnaud Savoure
ARAnne Rollin
Anne Rollin
FAFrederic Anselme
Frederic Anselme

1 February 2024 in European Heart Journal - Case Reports
Verified
Journal Article
Open access
PDF file
VSVasileios Sousonis
Vasileios Sousonis
QVQuentin Voglimacci-Stephanopoli
Quentin Voglimacci-Stephanopoli
SZSarah Zeriouh
Sarah Zeriouh
SBSerge Boveda
Serge Boveda
JAJean Paul Albenque
Jean Paul Albenque
Background: Ablation of persistent atrial fibrillation (AF) remains challenging, with atrial substrate modification often being performed as an adjunct to pulmonary vein isolation (PVI). Pulsed field ablation (PFA) is a novel ablation modality that carries a favourable safety profile, which could facilitate complex procedures. Case summary: We present the case of a 60-year-old male undergoing catheter ablation for symptomatic persistent AF. The procedure was performed with the Farapulse™ PFA system in a stepwise manner, including PVI and linear lesions for the isolation of the posterior left atrial wall and the ablation of the mitral isthmus. The final step of the procedure included the ablation of areas exhibiting spatiotemporal electrogram dispersion, identified with the help of artificial intelligence–based software (VX1, Volta Medical) in both atria. Sinus rhythm was restored after the abolition of an electrogram dispersion zone in the right atrium. The procedure was carried out without any complications. Discussion: Complex ablation procedures for persistent AF can be successfully performed with PFA. In the context of such extensive ablation strategies, PFA is an attractive energy source, given its non-thermal nature that is known to prevent damage to surrounding tissue and result in less chronic fibrosis. However, caution should be exercised to avoid excessive ablation when using the currently available multispline PFA catheter, as it may inadvertently target adjacent areas of healthy myocardium.

24 May 2024 in EP Europace
Verified
Journal Article
Open access
SZS Zeriouh
S Zeriouh
LKL Koutbi
L Koutbi
JMJulien Mancini
Julien Mancini
BMBaptiste Maille
Baptiste Maille
JHJ Hourdain
J Hourdain
JDJean Claude Deharo
Jean Claude Deharo
Background: Permanent cardiac pacing in paediatric patients remains a challenge. According to the European Paediatric and Congenital Society (AEPC) recommendations, below 20 kg epicardial implantation is preferred, while above 20 kg endocardial implantation is given priority unless specific contraindication. In the literature, a weight at 15 kg is also found to be the minimal weight above which an endovascular implantation is considered. However, endovascular systems have been reported to be associated with a high risk of complications. Recent improvements in epicardial leads technology have significantly improved pacing thresholds (1-3), battery life and reduced the risk of re-intervention for epicardial lead dysfunction (4,5). Purpose: The aim of the study is to evaluate the long-term results and efficacy of epicardial pacing in children and to investigate risk factors for epicardial lead dysfunction. Method: We performed a retrospective, single-centre analysis of consecutive patients aged ˂18 years implanted with an epicardial PM between 2004 and 2020. The data collection included initial pacing parameters, at 1 month, 1 year, 2 years, and at last follow-up, as well as occurrence of early and late complications. Results: A total of 101 patients (93 atrial and 131 ventricular epicardial) were analysed. The mean follow-up time was 6.2 years (range 2 days to 16.9 years). Median age at implantation was 4.2 years (IQ 0.3-8.8 years), median weight was 15.2 kg (IQ 5.2-28.0 kg). Congenital heart disease (CHD) was recorded in 59,4% of patients. Reasons for implantation were postoperative complete atrioventricular block (AVB) (40.6%), congenital AVB (37.6%), sinus dysfunction (7.9%), complete AVB with heart disease without surgery (7.9%), others (4%). Four patients had a system infection resulting in device extraction and reimplantation. The mortality rate was 15.8%, but no deaths was directly related to PM implantation or dysfunction. Detection values, impedances were stable over time, and the and average pacing thresholds remained ˂0,98±0,81 volt in the atrium and ˂ 1.57±0,89 volt in the ventricle. Lead survival was 96,7%, 90,7%, 82,3%, 74,5% at 1, 5, 8 and 10 years. The presence of CHD, weight ˂15kg, dual chamber implantation, implantation for postoperative BAV were not significant risk factors for lead dysfunction. In the group of patients implanted above 15kg the presence of a CHD significantly increased the risk of lead dysfunction (p=0.037) and all-cause reimplantation (p=0.010). In the group implanted above 15kg without any cardiopathy, the survival rate without lead dysfunction at 5 and 10 years was 100% and 90.9% respectively. Conclusion: Epicardial pacing in children with steroid-eluting leads shows good long-term results with stable pacing parameters and good survival from lead dysfunction. For children implanted at a weight above 15 kg and without cardiopathy results with epicardial stimulation were excellent.Epicardial lead survival