Ming Hu

Dr. Ming Hu

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 August 2025 in Classical and Quantum Gravity
Verified
Journal Article
Closed access
JLJun Luo
Jun Luo
SBShaojun Bai
Shaojun Bai
YBYanzheng Bai
Yanzheng Bai
LCLin Cai
Lin Cai
HDHao Dang
Hao Dang
JMJianwei Mei
Jianwei Mei
TianQin is a future space-based gravitational wave (GW) observatory targeting the frequency window of 10−4–1 Hz. A large variety of GW sources are expected in this frequency band, including the merger of massive black hole binaries, the inspiral of extreme/intermediate mass ratio systems, stellar-mass black hole binaries, Galactic compact binaries, and so on. TianQin will consist of three Earth orbiting satellites on nearly identical orbits with orbital radii of about 105 km. The satellites will form a normal triangle constellation whose plane is nearly perpendicular to the ecliptic plane. The TianQin project has been progressing smoothly following the ‘0123’ technology roadmap. In step ‘0’, the TianQin laser ranging station has been constructed and it has successfully ranged to all the five retro-reflectors on the Moon. In step ‘1’, the drag-free control technology has been tested and demonstrated using the TianQin-1 satellite. In step ‘2’, the inter-satellite laser interferometry technology will be tested using the pair of TianQin-2 satellites. The TianQin-2 mission has been officially approved and the satellites will be launched around 2026. In step ‘3’, i.e. the TianQin-3 mission, three identical satellites will be launched around 2035 to form the space-based GW detector, TianQin, and to start GW detection in space.

21 September 2023 in Classical and Quantum Gravity
Verified
Journal Article
Closed access
CWChengrui Wang
Chengrui Wang
YBYanzheng Bai
Yanzheng Bai
MHMing Hu
Ming Hu
DLDuo Li
Duo Li
KLKe Li
Ke Li
ZZZebing Zhou
Zebing Zhou
Capacitive sensing electronics are critical to space gravitational wave detection missions, providing the test mass motion information for the inertial sensor’s non-sensitive axis control and the drag-free control of the satellite. For the TianQin mission, the capacitive sensor requirement is 6.9 × 10 − 7 p F H z − 1 / 2 at 6 mHz, corresponding to a displacement noise of 1.7 n m H z − 1 / 2 . This paper presents the system design scheme, noise analysis, and performance testing of the capacitive sensor for the TianQin mission. Based on the previous work of our group, a capacitive sensing scheme based on a transformer bridge and modulation–demodulation is adopted. A transformer with a better high LQ product is fabricated, and the preamplifier current noise is reduced to further improve the performance above mHz. The amplitude stability of the AC carrier and the performance of the lock-in amplifier circuit are further improved to reduce the low-frequency 1 / f noise at m H z and below. Finally, a capacitive sensor prototype is developed and tested, the experimental results show that the capacitance measurement noise is better than 3 × 10 − 7 p F H z − 1 / 2 above 1 mHz and better than 6 × 10 − 7 p F H z − 1 / 2 at about 0.1 mHz , which meets the overall performance requirement of the TianQin mission.

13 August 2015 in Journal of Neural Engineering
Verified
Journal Article
Open access
JFJose A Fernandez-Leon
Jose A Fernandez-Leon
APArun Parajuli
Arun Parajuli
RFRobert Franklin
Robert Franklin
MSMichael Sorenson
Michael Sorenson
DFDaniel J Felleman
Daniel J Felleman
VDValentin Dragoi
Valentin Dragoi
Studying the brain in large animal models in a restrained laboratory rig severely limits our capacity to examine brain circuits in experimental and clinical applications. To overcome these limitations, we developed a high-fidelity 96-channel wireless system to record extracellular spikes and local field potentials from the neocortex. A removable, external case of the wireless device is attached to a titanium pedestal placed in the animal skull. Broadband neural signals are amplified, multiplexed, and continuously transmitted as TCP/IP data at a sustained rate of 24 Mbps. A Xilinx Spartan 6 FPGA assembles the digital signals into serial data frames for transmission at 20 kHz though an 802.11n wireless data link on a frequency-shift key-modulated signal at 5.7-5.8 GHz to a receiver up to 10 m away. The system is powered by two CR123A, 3 V batteries for 2 h of operation. We implanted a multi-electrode array in visual area V4 of one anesthetized monkey (Macaca fascicularis) and in the dorsolateral prefrontal cortex (dlPFC) of a freely moving monkey (Macaca mulatta). The implanted recording arrays were electrically stable and delivered broadband neural data over a year of testing. For the first time, we compared dlPFC neuronal responses to the same set of stimuli (food reward) in restrained and freely moving conditions. Although we did not find differences in neuronal responses as a function of reward type in the restrained and unrestrained conditions, there were significant differences in correlated activity. This demonstrates that measuring neural responses in freely moving animals can capture phenomena that are absent in the traditional head-fixed paradigm. We implemented a wireless neural interface for multi-electrode recordings in freely moving non-human primates, which can potentially move systems neuroscience to a new direction by allowing one to record neural signals while animals interact with their environment.

1 June 2022 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
KLKe Li
Ke Li
HYHang Yin
Hang Yin
CSChi Song
Chi Song
MHMing Hu
Ming Hu
SWShun Wang
Shun Wang
ZZZebing Zhou
Zebing Zhou
Patch effect is important for ultra-sensitive experiments involving closely spaced conducting surfaces. A scanning probe equipped torsion pendulum is an experimental apparatus for measuring spatial resolved patch potential on conductive surfaces. An effective approach to improve its measurement precision is by the optimization on the amplitude and frequency of the injected signal in the probe. In this paper, a method based on single- and double-frequency signal injection modes is proposed. The analysis results demonstrate that the potential resolution could achieve the level of 2–4 μV/Hz1/2. In the same integration time, the surface potential precision in the double-frequency mode is twice better than that in the single-frequency mode. In addition, when achieving the same measurement precision, the double-frequency mode takes less time than the single-frequency mode, which improves the measuring efficiency.

1 February 2023 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
CSChi Song
Chi Song
MHMing Hu
Ming Hu
KLKe Li
Ke Li
PLPeng-Shun Luo
Peng-Shun Luo
SWShun Wang
Shun Wang
ZZZebing Zhou
Zebing Zhou
The physical mechanism of the patch effect is still an open question. Thus, a high-precision surface potential mapping facility based on a specially designed electrostatically-controlled torsion pendulum is proposed in this paper. The facility not only features high sensitivity and a two-dimensional mapping function but also adapts to various measurement requirements for centimeter-sized samples. The sensitivity of the torsion pendulum reaches about 2.0 × 10−14 N m/Hz1/2 in a frequency range of 1–8 mHz. The temporal variation of the surface potential can be detected at a level of 30 μV/Hz1/2 with a probe whose surface area is 7 mm2. The potential spatial distribution resolution comes to 0.1 mm2 at a level of 40 μV with 1 h integration time.

29 August 2023 in Classical and Quantum Gravity
Verified
Journal Article
Closed access
AZAn-Nan Zhou
An-Nan Zhou
YBYanzheng Bai
Yanzheng Bai
LCLin Cai
Lin Cai
MHMing Hu
Ming Hu
HLHong-Yin Li
Hong-Yin Li
ZZZebing Zhou
Zebing Zhou
High-precision electrostatic accelerometer has been widely employed in gravity measurement satellites. Accelerometer can be designed for different resolutions and measurement ranges to adapt to different scientific missions. This paper presents an ultra-high sensitivity 70 g-TM electrostatic accelerometer, designed to achieve an adjustable resolution from 10 − 12 m s − 2 Hz − 1 / 2 to 10 − 10 m s − 2 Hz − 1 / 2 with an optimal resolution of 3.3 × 10 − 12 m s − 2 Hz − 1 / 2 . The in-orbit performance of the 70 g-TM accelerometer was tested on the Tianqin-1 satellite.