3 April 2025 in Measurement Science and Technology
Inertial sensor (IS) is one of the most critical units in space-based gravitational wave detection projects. Any actuation to sensing crosstalk in the IS might lead to operational anomalies in sensing electronics, thereby affecting the closed loop control of the test mass. The theoretical model for the crosstalk has been analyzed and verified. A secondary-tuning method is proposed to suppress the actuation to sensing crosstalk. Considering the influence of the circuit’s stray capacitance which acts as the equivalent primary resonance tuning capacitance, experimental results indicate that the secondary-tuning method could attenuate the crosstalk factor by 5, compared to the traditional primary-tuning method. The actuation to sensing crosstalk is reduced, and then the measurement accuracy of the displacement sensor is relatively improved. Based on the theoretical crosstalk model, the criteria for selecting the basis function waveform of the feedback voltage are provided. When the basis function of the feedback voltage is selected to be a 150 V sinusoidal signal, the primary-tuning method requires a frequency of less than 337 Hz, while the secondary-tuning method allows for a frequency of less than 528 Hz according to the experimental results. The requirement for the feedback voltage frequency in the secondary-tuning method has been relaxed nearly by a factor of 1.5, which allows for large frequency intervals and could suppress the coupling between the actuator’s degrees of freedom.
11 June 2025 in Measurement Science and Technology
Electrostatic actuation of the gravitational reference system is critical for TianQin. This actuation must function effectively in both wide range and high resolution modes. However, amplitude fluctuations of the AC control voltage on non-sensitive axes can adversely affect the sensitivity of the sensitive axis, imposing stringent requirements on the amplitude stability of AC actuation. Traditional open-loop actuation, constrained by the limitations of the high-voltage amplifier (HVA), has difficulty meeting this demand. To address this, we developed an AC actuation prototype based on the noise shaping technique to suppress the HVA gain instability. Furthermore, we built an evaluation platform with a measurement resolution of 0.05 at 1 mHz to assess AC amplitude stability. Experimental results demonstrate that the actuation improves AC amplitude stability from 8 in the open loop design to 1 at 1 mHz. Further analysis indicates that the ADC’s voltage reference is the primary factor limiting amplitude stability, providing a clear pathway for future optimization.
4 November 2024 in Measurement Science and Technology
Capacitive displacement transducers play a crucial role in inertial sensors especially for space gravitational wave detection missions. One of the major requirements for the displacement transducer is to have a lower sensing offset. The sensing offset will adversely affect the accuracy of the absolute position measurement of the test mass, providing erroneous data to the drag-free controller and leading to spacecraft mispositioning. Additionally, the offset could introduce multiplicative noise to the sensing output and the closed loop output of the inertial sensor. The asymmetry of the sensing bridge within the front-end electronics has been identified as the primary source of these offsets. This paper analyzes the requirements of the main parameters in the sensing bridge. A method is proposed to reduce the sensing offset by utilizing differentiated resonant capacitors while maintaining the ability to tune the resonant frequency and ensure a sufficiently low sensing noise level. Experimental results show that this approach can effectively reduce the residual sensing offset to (−15.7 ± 5.0) ppm, which satisfies the stringent requirement for space inertial sensors in the TianQin mission.
13 January 2026 in Measurement Science and Technology
To realize the free falling test mass (TM) in gravitational wave detection in space, an alternative current (AC) electrostatic control strategy is proposed and developed. It is significant to test and verify the AC control actuation scheme on the ground. In this paper, a two-stage torsion pendulum is used to test the performance of the AC control actuator of inertial sensor for Tianqin project. First, the pendulum facility combined with a TM, a capacitive position sensor and an AC control actuator is constructed. Experimental results show that the sensitivities of the pendulum achieve 4.2 × 10 −11 N Hz −1/2 at 6 mHz and 1.6 × 10 −13 Nm Hz −1/2 at 15 mHz, respectively, and the pendulum provides a chance to realize the performance test of two degree-of-freedom sensitivities of the actuator, experimental verification of AC control strategy and so on, which is first reported to test performance of the AC control actuator of a space inertial sensor on the ground.
21 November 2025 in Classical and Quantum Gravity
Releasing the test mass (TM) is a critical phase of inertial sensors for gravitational wave detection. The grabbing positioning and release mechanism inevitably generates large initial momentum making TM capture control particularly challenging. To maximize the controllable range, this paper presents a time-division control strategy for the TM release phase. Simulation results show that the proposed method significantly enlarges the capture range, enabling robust capture under large initial state.
30 October 2025 in Measurement