Hang Yin

Hang Yin

Auto-generated profile, based on publicly available information

Hang Yin

Huazhong University of Science and Technology

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 August 2017 in Sensors
Verified
Journal Article
Open access
PDF file
YBYanzheng Bai
Yanzheng Bai
ZLZhuxi Li
Zhuxi Li
MHMing Hu
Ming Hu
LLLi Liu
Li Liu
SQShaobo Qu
Shaobo Qu
ZZZebing Zhou
Zebing Zhou
High-precision electrostatic accelerometers have achieved remarkable success in satellite Earth gravity field recovery missions. Ultralow-noise inertial sensors play important roles in space gravitational wave detection missions such as the Laser Interferometer Space Antenna (LISA) mission, and key technologies have been verified in the LISA Pathfinder mission. Meanwhile, at Huazhong University of Science and Technology (HUST, China), a space accelerometer and inertial sensor based on capacitive sensors and the electrostatic control technique have also been studied and developed independently for more than 16 years. In this paper, we review the operational principle, application, and requirements of the electrostatic accelerometer and inertial sensor in different space missions. The development and progress of a space electrostatic accelerometer at HUST, including ground investigation and space verification are presented.

20 August 2020 in Classical and Quantum Gravity
Verified
Journal Article
Closed access
WSWei Su
Wei Su
YWYan Wang
Yan Wang
ZZZe-Bing Zhou
Ze-Bing Zhou
YBYan-Zheng Bai
Yan-Zheng Bai
YGYang Guo
Yang Guo
BZBu-Tian Zhang
Bu-Tian Zhang
TianQin is a proposed space-based gravitational wave observatory. It is designed to detect the gravitational wave signals in the frequency range of 0.1 mHz–1 Hz. At a geocentric distance of 10 5 km, the plasma in the Earth magnetosphere will contribute as the main source of environmental noises. Here, we analyze the acceleration noises that are caused by the magnetic field of space plasma for the test mass of TianQin. The real solar wind data observed by the Advanced Composition Explorer are taken as the input of the magnetohydrodynamic simulation. The Space Weather Modeling Framework is used to simulate the global magnetosphere of the Earth, from which we obtain the plasma and magnetic field parameters on the detector’s orbits at φ s = 0°, 30°, 60° and 90°, where φ s is the acute angle between the line that joins the Sun and the Earth and the projection of the normal of the detector’s plane on the ecliptic plane. We calculate the time series of the residual accelerations and the corresponding amplitude spectral densities on these orbit configurations. We find that the residual acceleration produced by the interaction between the TM’s magnetic moment induced by the space magnetic field and the spacecraft magnetic field ( a M1 ) is the dominant term, which can approach 10 −15 m s –2 Hz –1/2 at f ≈ 0.2 mHz for the nominal values of the magnetic susceptibility ( χ m = 10 −5 ) and the magnetic shielding factor ( ξ m = 10) of the test mass. The ratios between the amplitude spectral density of the acceleration noise caused by the space magnetic field and the preliminary goal of the inertial sensor are 0.38 and 0.08 at 1 mHz and 10 mHz, respectively. We discuss the further reduction of this acceleration noise by decreasing χ m and/or increasing ξ m in the future instrumentation development for TianQin.

5 July 2022 in Classical and Quantum Gravity
Verified
Journal Article
Closed access
CXChunyu Xiao
Chunyu Xiao
YBYanzheng Bai
Yanzheng Bai
HLHongyin Li
Hongyin Li
LLLi Liu
Li Liu
YLYanchong Liu
Yanchong Liu
ZZZebing Zhou
Zebing Zhou
Drag-free control (DFC) is one of the key technologies for space-borne gravitational wave detectors. For the TianQin (TQ) project, non-gravitational disturbances on the spacecraft must be suppressed by DFC. TianQin-1 (TQ-1) is the first satellite for technology verification, whose main goal is to verify the disturbances reduction technologies. In this paper, the DFC requirement and preliminary analysis for the TQ project are introduced, and then the design and the experimental validation with the TQ-1 satellite is presented. In-orbit results show a successful validation of DFC and the residual acceleration of TQ-1 satellite has been suppressed to 5 × 1 0 − 11 m s − 2 H z − 1 / 2 at 10 mHz versus 2 × 1 0 − 9 m s − 2 H z − 1 / 2 thruster noise.

1 February 2023 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
CSChi Song
Chi Song
MHMing Hu
Ming Hu
KLKe Li
Ke Li
PLPeng-Shun Luo
Peng-Shun Luo
SWShun Wang
Shun Wang
ZZZebing Zhou
Zebing Zhou
The physical mechanism of the patch effect is still an open question. Thus, a high-precision surface potential mapping facility based on a specially designed electrostatically-controlled torsion pendulum is proposed in this paper. The facility not only features high sensitivity and a two-dimensional mapping function but also adapts to various measurement requirements for centimeter-sized samples. The sensitivity of the torsion pendulum reaches about 2.0 × 10−14 N m/Hz1/2 in a frequency range of 1–8 mHz. The temporal variation of the surface potential can be detected at a level of 30 μV/Hz1/2 with a probe whose surface area is 7 mm2. The potential spatial distribution resolution comes to 0.1 mm2 at a level of 40 μV with 1 h integration time.

1 June 2022 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
KLKe Li
Ke Li
HYHang Yin
Hang Yin
CSChi Song
Chi Song
MHMing Hu
Ming Hu
SWShun Wang
Shun Wang
ZZZebing Zhou
Zebing Zhou
Patch effect is important for ultra-sensitive experiments involving closely spaced conducting surfaces. A scanning probe equipped torsion pendulum is an experimental apparatus for measuring spatial resolved patch potential on conductive surfaces. An effective approach to improve its measurement precision is by the optimization on the amplitude and frequency of the injected signal in the probe. In this paper, a method based on single- and double-frequency signal injection modes is proposed. The analysis results demonstrate that the potential resolution could achieve the level of 2–4 μV/Hz1/2. In the same integration time, the surface potential precision in the double-frequency mode is twice better than that in the single-frequency mode. In addition, when achieving the same measurement precision, the double-frequency mode takes less time than the single-frequency mode, which improves the measuring efficiency.

29 August 2023 in Classical and Quantum Gravity
Verified
Journal Article
Closed access
AZAn-Nan Zhou
An-Nan Zhou
YBYanzheng Bai
Yanzheng Bai
LCLin Cai
Lin Cai
MHMing Hu
Ming Hu
HLHong-Yin Li
Hong-Yin Li
ZZZebing Zhou
Zebing Zhou
High-precision electrostatic accelerometer has been widely employed in gravity measurement satellites. Accelerometer can be designed for different resolutions and measurement ranges to adapt to different scientific missions. This paper presents an ultra-high sensitivity 70 g-TM electrostatic accelerometer, designed to achieve an adjustable resolution from 10 − 12 m s − 2 Hz − 1 / 2 to 10 − 10 m s − 2 Hz − 1 / 2 with an optimal resolution of 3.3 × 10 − 12 m s − 2 Hz − 1 / 2 . The in-orbit performance of the 70 g-TM accelerometer was tested on the Tianqin-1 satellite.