Hüseyin Tayyer CANSEVEN

Dr. Hüseyin Tayyer CANSEVEN

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 March 2022 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
ABALI BAKBAK
ALI BAKBAK
HCHüseyin Tayyer CANSEVEN
Hüseyin Tayyer CANSEVEN
Murat AyazMurat Ayaz
Murat Ayaz
MAMert Altintas
Mert Altintas
EMErkan Mese
Erkan Mese
Direct grid coupling of permanent magnet synchronous generators (PMSG) for wind energy conversion systems provides certain advantages with the penalties of maximum power point tracking (MPPT) and reactive power control. This article proposes a novel PMSG design philosophy such that optimizing PMSG design at the initial stage would compensate for the drawbacks arising from the lack of an MPPT algorithm. Also, the ability to maintain a high PF across a wide range of operating power levels is investigated by considering reactive power in the design process. In this article, optimization of slot/pole combination is described for direct grid coupled PMSGs to extract as much energy as possible according to wind data. A new benchmark, adequacy factor, is presented to determine the slot/pole combination. Variation of the reactive power is theoretically analyzed. A relationship is established between induced electromotive force, synchronous inductance values of machines, and the PF. Fixed and variable speed operations of PMSGs are compared in terms of annual energy yield. Finally, theoretical analyses are validated through laboratory testing of prototype generators.

19 April 2025 in Applied Thermal Engineering
Verified
Journal Article
Open access
IPIlya Petrov
Ilya Petrov
ACAndrea Credo
Andrea Credo
HCHüseyin Tayyer CANSEVEN
Hüseyin Tayyer CANSEVEN
SSShruti Singh
Shruti Singh
TNTimo Nykänen
Timo Nykänen
JPJuha Pyrhönen
Juha Pyrhönen

24 August 2021 in IEEE Access
Verified
Journal Article
Open access
ABALI BAKBAK
ALI BAKBAK
MAMert Altintas
Mert Altintas
Murat AyazMurat Ayaz
Murat Ayaz
HCHüseyin Tayyer CANSEVEN
Hüseyin Tayyer CANSEVEN
MBMutlu Boztepe
Mutlu Boztepe
EMErkan Mese
Erkan Mese
In this study, a dual-port wind-energy conversion system has been proposed. A double-fed permanent-magnet synchronous generator (DFPMSG) forms the central part of the system, where the concentrated single-layer winding configuration of the generator enables electric and magnetic isolation between the ports. DFPMSG has two three-phase terminals out of the stator; one is connected directly to the grid, whereas the other is tied to the grid through a back-to-back converter. This study investigates design issues caused by the DFPMSG port with a direct grid connection. The unique design issues of the proposed system include determining the slot/pole combination using wind data and determining the minimum reactive power requirement for the port with a direct grid connection. Next, the load-sharing capability among the ports of the proposed system is presented through a detailed investigation of three schemes. Experimental work is presented for a 5-kW prototype DFPMSG system to illustrate the isolation among the ports, minimized reactive power demand on the port with direct grid connection, and load-sharing ability among the ports for different control schemes.

25 November 2025 in IEEE Access
Verified
Journal Article
Open access
HCHüseyin Tayyer CANSEVEN
Hüseyin Tayyer CANSEVEN
Advanced thermal management is crucial for high-power-density electric machines with hairpin windings to ensure reliability and performance. This paper presents a comparative thermal analysis of an embedded permanent magnet synchronous machine, evaluating two in-slot cooling arrangements: slot oil cooling (SOC) and direct oil cooling (DOC). While these advanced in-slot cooling methods are employed to manage the thermal challenges, a critical gap exists in the literature regarding a direct, quantitative comparison of their practical limits, particularly under transient overload conditions. This paper directly addresses this critical gap to provide a definitive answer. The primary contribution of this work is to provide a significant and quantitative comparison that moves beyond simple steady-state analysis to reveal under realistic operating conditions. The analysis utilizes 2D Finite Element Method (FEM) simulations, with heat sources derived from electromagnetic calculations and convective boundary conditions established through analytical modeling, which were anchored by experimental validation to ensure high accuracy. A steady-state analysis across multiple operating points reveals that while DOC consistently reduces peak winding temperature by 15 °C, its necessity becomes critical at high speeds; the SOC system exceeds the thermal limit of the winding insulation class at the maximum speed condition. In contrast, the DOC system maintains temperatures safely within this limit across the entire operational range. Alternatively, the DOC enables a 20% increase in torque output for the same thermal limit. Additionally, a transient overload analysis demonstrates the robustness of DOC safely managing thermal stress, while the SOC arrangement exceeds the thermal limits, posing an unacceptable risk to motor longevity. This study concludes that DOC is not a performance enhancement but a critical and enabling technology for ensuring the operational reliability and achieve the full potential of hairpin winding machines in demanding applications.

23 January 2024 in IEEE Transactions on Industry Applications
Verified
Journal Article
Open access
HCHüseyin Tayyer CANSEVEN
Hüseyin Tayyer CANSEVEN
IPIlya Petrov
Ilya Petrov
JPJuha Pyrhönen
Juha Pyrhönen
Permanent Magnet Synchronous Machines (PMSMs) are commonly employed in applications demanding a high specific power. To achieve high specific power values, a high pole pair number PMSM with very thin yokes can be built. Such a design leads to a high operating frequency. At high operating frequencies, AC losses can more than double the DC losses if solid hairpin technology or traditional bunches of nontransposed round enameled wires are used in the stator windings of machines with a considerable power. Against this negative effect, the emerging Litz wire coil technology with prefabricated coils can be used. In this study, firstly, alternative stator slot geometries required when using prefabricated Litz wire coils are evaluated. A symmetric semi-closed slot is not suitable for inserting such prefabricated Litz wire coils into the stator slots. Instead, an asymmetric semi-closed slot can be used, and it may even offer a better performance than the symmetric open slot. After showing that the asymmetric semi-closed slot provides a better performance, it is investigated how this asymmetric stator slot geometry can be used beneficially. The findings were first studied with finite element analysis (FEA) and then experimentally verified on a high-specific-power machine.

17 October 2024 in IEEE Transactions on Energy Conversion
Verified
Journal Article
Open access
HCHüseyin Tayyer CANSEVEN
Hüseyin Tayyer CANSEVEN
IPIlya Petrov
Ilya Petrov
IMIikka Martikainen
Iikka Martikainen
JPJuha Pyrhönen
Juha Pyrhönen
In recent years, high-speed PMSMs have gained popularity due to advancements in materials, manufacturing, and high-switching-frequency power electronics. However, the design and manufacturing of high-speed PMSMs presents challenges such as high centrifugal forces and complexities of thermal management. Solid rotor cores are used to address these issues, although they may suffer from high eddy-current losses. Slits on the rotor surface can mitigate these challenges. In the region without slits, the end effect is negligible, but in the slitted region, a significant end effect caused by current circulation in narrow areas must be considered. Traditional methods for calculating eddy-current losses are insufficient for such designs. In this study, firstly, the slit geometry is introduced, and it is explained why traditional FEM methods are insufficient to calculate eddycurrent losses for such rotors. After that, a fast and reliable method for evaluating eddy-current losses in a slitted solid rotor is proposed. Experimental tests are carried out separately on scaled prototypes of the rotor with and without slits, and the results are compared with 2D and 3D FEM results. After the validation of the proposed method, it is used in the solid rotor of a PMSM. Rotor losses are compared in the PMSM equipped with different solid rotors, either with or without slits